Code H6 on a Gree air conditioner: the indoor fan isn't turning

This is what you see on the indoor unit's display. The unit stops and no air comes out of the indoor unit.

Short answer

The board runs the indoor fan and monitors its speed with a sensor. If the fan doesn't turn, or turns at the wrong speed, the unit stops and shows H6. Sometimes something is blocking the fan, and sometimes it is the motor itself.

Is it dangerous?
No
Does it clear by itself?
No
Can I fix it myself?
Checking for obstructions only

What to do now, in order

  1. Turn off the power at the breaker

    before opening the indoor unit's front cover.

    Safe for you
  2. Look for an obstruction or ice

    Open the front cover and look at the cylindrical fan: dirt, an insect nest, a piece of plastic, or ice on the blades.

    Safe for you
  3. Turn the fan with your finger

    with the power off. It should turn freely. If it is stiff or rattles, the bearing is usually worn.

    Safe for you
  4. Clean the filter and restart

    If you removed an obstruction, let any ice melt, clean the filter, then restore the power, wait 3 minutes and try.

    Safe for you

If H6 comes straight back, don't check the wiring or the board yourself.

Causes, from most to least likely

Faulty indoor fan motor

Most common

A worn bearing or a burnt winding. Most common when the fan is stiff to turn.

Fan blocked by dirt or ice

The only thing you can safely check yourself.

Speed sensor or signal wire

The motor turns but the board doesn't receive its speed signal.

Indoor control board

After ruling out the motor and the wiring.

What to tell the technician

My Gree air conditioner shows code H6. With the power off, the indoor fan [turns freely / is stiff] by hand, and nothing is blocking it. I want the fan motor and the speed signal wire checked before the board.

Edit the part in brackets to match what you found. That alone points the technician to the motor or the wiring.

Frequently asked questions

Is H6 the same as E6?

No. E6 is a communication fault between the units, while H6 concerns the indoor fan.

How does ice form on the fan?

Usually because of a very dirty filter or low refrigerant, which makes the evaporator colder than it should be.

Is a fan motor expensive?

It is usually cheaper than the control board, which is why it is checked first.