A3tali

Home ‹ Air conditioners ‹ Gree

Gree air conditioner error codes

60 codes, each with what it means, what you can safely try yourself, and when to call a technician. One of the most widespread air conditioner brands in the Gulf. Its codes are a letter and a number, such as E6 and H5.

17 of the 60 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
E1High-pressure protectionTry it yourself first
E2Freeze protection in cooling modeTry it yourself first
E3Low-pressure protectionTry it yourself first
E4Compressor discharge high-temperature protectionTry it yourself first
E5Overcurrent protectionNeeds a technician
E6Lost communication between the indoor and outdoor unitsTry it yourself first
E7Mode conflictTry it yourself first
E8Overheating protection, linked to the indoor fan or its boardNeeds a technician
EEBoard memory fault (EEPROM)Needs a technician
EHAuxiliary heater faultNeeds a technician
EUFrequency reduced because the IPM power module is hotNeeds a technician
F0Low refrigerantNeeds a technician
F1Indoor room temperature sensor faultNeeds a technician
F2Indoor evaporator sensor faultNeeds a technician
F3Outdoor ambient temperature sensor faultNeeds a technician
F4Outdoor pipe sensor faultNeeds a technician
F5Discharge temperature sensor faultNeeds a technician
F7Oil return in progressNot a fault
F9Frequency reduced because of high discharge temperatureNeeds a technician
FAFrequency reduced because of high pipe temperatureNeeds a technician
FCSliding door problemNeeds a technician
FECompressor overload sensor faultNeeds a technician
FHFrequency reduced by the anti-freeze limitTry it yourself first
H0Frequency reduced because of high temperature in heating modeNeeds a technician
H1Defrost modeNot a fault
H2Electrostatic precipitator protectionNeeds a technician
H3Compressor overload protectionNeeds a technician
H4System overload or high pipe temperatureTry it yourself first
H5IPM power module protectionNeeds a technician
H6Indoor fan motor not sending a signalNeeds a technician
H7Compressor out of step (desynchronised)Needs a technician
HCPFC circuit protectionNeeds a technician
HECompressor demagnetisation protectionNeeds a technician
L3Outdoor fan motor faultNeeds a technician
L9Power protectionNeeds a technician
LCCompressor failed to startNeeds a technician
LDMissing phase in the compressor supplyNeeds a technician
LECompressor stopped because it is lockedNeeds a technician
P0Drive module reset problemNeeds a technician
P5Overcurrent protection on one compressor phaseNeeds a technician
P6Lost communication between the main board and the drive boardNeeds a technician
P7Power module temperature sensor circuit faultNeeds a technician
P8Power module overheating protectionNeeds a technician
PAInput overcurrent protectionNeeds a technician
PCCurrent sensing circuit faultNeeds a technician
PHOvervoltage protectionNeeds a technician
PLUndervoltage protectionNeeds a technician
PUCapacitor charging circuit faultNeeds a technician
U1Compressor phase current sensing circuit faultNeeds a technician
U2Compressor phase loss protectionNeeds a technician
U3DC bus voltage dropNeeds a technician
U4Compressor reverse rotation protectionNeeds a technician
U5AC current sensing circuit faultNeeds a technician
U7Four-way valve faultNeeds a technician
U8Discharge temperature sensor disconnectedNeeds a technician
U9AC zero-crossing detection errorNeeds a technician
C5Jumper problemNeeds a technician
oEPFC circuit overheating or its sensor faultNeeds a technician
b5Inlet pipe sensor faultNeeds a technician
b7Outlet pipe sensor faultNeeds a technician

Every code explained

Everything under “What you can do” is done without opening any cover. Opening the air conditioner or measuring its wiring with the power on is a technician's job.

E1 High-pressure protection Try it yourself first

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
Reported causes
Dirty coils, blockage, too much refrigerant
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.
Detailed explanation
Causes in order, steps, and what to tell the technician →

E2 Freeze protection in cooling mode Try it yourself first

What it means
The indoor coil got colder than it should and started to freeze, so the unit stopped the compressor to protect it.
Reported causes
Blocked filter, dirty cooling coil, low refrigerant, faulty fan
What you can do
Clean the air filter, raise the fan speed, and don't set the temperature to the lowest setting for long periods. Leave the unit on fan mode until the ice melts.
When to call a technician
If the code keeps appearing with a clean filter, the refrigerant may be low or the fan weak.

E3 Low-pressure protection Try it yourself first

What it means
There is less refrigerant in the system than needed, usually because of a leak.
Reported causes
Dirty filters or coils, refrigerant leak
What you can do
Clean the filter and confirm that cooling really is weak. There is nothing else to do on your side.
When to call a technician
In almost every case. Ask the technician to find and repair the leak before recharging; recharging alone is only a temporary fix.

E4 Compressor discharge high-temperature protection Try it yourself first

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
Reported causes
Dirty filters, blocked condenser or evaporator
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

E5 Overcurrent protection Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
Reported causes
High or unstable supply voltage
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

E6 Lost communication between the indoor and outdoor units Try it yourself first

What it means
The indoor and outdoor units (or two boards inside the unit) exchange a signal over a wire, and that signal has been lost.
Reported causes
Wrong wire or one joined from two pieces, loose terminals, damaged cable, damaged board
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Make sure the outdoor unit's breaker is on. Note whether the code started after installation, relocation or a power cut.
When to call a technician
If the code comes back after restarting. Checking the cable and terminals is done with the power on, which is a technician's job.
Note
On 380 V systems it can appear when the phase order is reversed

Detailed page about this code

E7 Mode conflict Try it yourself first

What it means
The air conditioner detected a fault and stopped because of it.
Reported causes
The indoor and outdoor units are set to different modes
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

E8 Overheating protection, linked to the indoor fan or its board Needs a technician

What it means
The fan is not turning, or it turns but the unit does not receive its rotation signal.
Reported causes
Faulty indoor fan motor, defective indoor board
What you can do
Turn the unit off and check whether anything is blocking the fan: built-up dirt, a leaf or a foreign object. Never put your hand in while the power is on.
When to call a technician
If the fan turns freely but does not run. The motor, its capacitor or the board needs testing.
Note
Both sources agree on the part but name the code differently

EE Board memory fault (EEPROM) Needs a technician

What it means
A fault in the electronic control board or one of its parts.
Reported causes
Damaged memory chip on the outdoor unit board
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Sometimes the fault is temporary after a power fluctuation.
When to call a technician
If the code comes back. The board is tested and repaired or replaced; ask for a diagnosis before agreeing to replace it, as it is one of the most expensive parts.

F0 Low refrigerant Needs a technician

What it means
There is less refrigerant in the system than needed, usually because of a leak.
What you can do
Clean the filter and confirm that cooling really is weak. There is nothing else to do on your side.
When to call a technician
In almost every case. Ask the technician to find and repair the leak before recharging; recharging alone is only a temporary fix.
Note
Arlington also calls it refrigerant recovery mode
Detailed explanation
Causes in order, steps, and what to tell the technician →

F1 Indoor room temperature sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
Reported causes
Damaged or disconnected sensor
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

F2 Indoor evaporator sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
Reported causes
Damaged sensor or wiring
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

F3 Outdoor ambient temperature sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
Reported causes
Damaged or disconnected sensor
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

F4 Outdoor pipe sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
Reported causes
Damaged sensor or sensor moved out of place
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

F5 Discharge temperature sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
Reported causes
Damaged sensor or wiring
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

F9 Frequency reduced because of high discharge temperature Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

FA Frequency reduced because of high pipe temperature Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

H1 Defrost mode Not a fault

What it means
An operating status, not a fault. The unit is telling you what it is doing right now.
Reported causes
Appears in heating while ice is melted off the outdoor unit
What you can do
Nothing. Wait until the code disappears by itself.
When to call a technician
If the code stays for hours or keeps appearing without a clear reason.
Note
Only check it if it lasts long or keeps happening

H3 Compressor overload protection Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
Reported causes
Compressor overload
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

H4 System overload or high pipe temperature Try it yourself first

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
Reported causes
Blocked heat exchanger
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

H5 IPM power module protection Needs a technician

What it means
A fault in the electronic control board or one of its parts.
Reported causes
Voltage or temperature problems
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Sometimes the fault is temporary after a power fluctuation.
When to call a technician
If the code comes back. The board is tested and repaired or replaced; ask for a diagnosis before agreeing to replace it, as it is one of the most expensive parts.

H6 Indoor fan motor not sending a signal Needs a technician

What it means
The fan is not turning, or it turns but the unit does not receive its rotation signal.
Reported causes
Indoor fan obstructed or its motor faulty
What you can do
Turn the unit off and check whether anything is blocking the fan: built-up dirt, a leaf or a foreign object. Never put your hand in while the power is on.
When to call a technician
If the fan turns freely but does not run. The motor, its capacitor or the board needs testing.
Detailed explanation
Causes in order, steps, and what to tell the technician →

H7 Compressor out of step (desynchronised) Needs a technician

What it means
A problem running the compressor, the heart of the air conditioner.
Reported causes
Problem with the compressor motor
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back. Do not keep retrying, so the compressor is not damaged.

HC PFC circuit protection Needs a technician

What it means
A fault in the electronic control board or one of its parts.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Sometimes the fault is temporary after a power fluctuation.
When to call a technician
If the code comes back. The board is tested and repaired or replaced; ask for a diagnosis before agreeing to replace it, as it is one of the most expensive parts.

L3 Outdoor fan motor fault Needs a technician

What it means
The fan is not turning, or it turns but the unit does not receive its rotation signal.
Reported causes
The fan isn't turning or its supply is weak
What you can do
Turn the unit off and check whether anything is blocking the fan: built-up dirt, a leaf or a foreign object. Never put your hand in while the power is on.
When to call a technician
If the fan turns freely but does not run. The motor, its capacitor or the board needs testing.

L9 Power protection Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
Reported causes
Large sudden power surge
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

LC Compressor failed to start Needs a technician

What it means
A problem running the compressor, the heart of the air conditioner.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back. Do not keep retrying, so the compressor is not damaged.

LD Missing phase in the compressor supply Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

LE Compressor stopped because it is locked Needs a technician

What it means
A problem running the compressor, the heart of the air conditioner.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back. Do not keep retrying, so the compressor is not damaged.

P5 Overcurrent protection on one compressor phase Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
Reported causes
Unstable voltage
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

P6 Lost communication between the main board and the drive board Needs a technician

What it means
The indoor and outdoor units (or two boards inside the unit) exchange a signal over a wire, and that signal has been lost.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Make sure the outdoor unit's breaker is on. Note whether the code started after installation, relocation or a power cut.
When to call a technician
If the code comes back after restarting. Checking the cable and terminals is done with the power on, which is a technician's job.
Note
Inside the outdoor unit; different from E6

P7 Power module temperature sensor circuit fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

P8 Power module overheating protection Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

PA Input overcurrent protection Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

PC Current sensing circuit fault Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
Reported causes
Open, burnt or shorted circuit
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

PH Overvoltage protection Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
Reported causes
Input voltage above 264 V
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.
Note
Voltage figure from Arlington only

PL Undervoltage protection Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
Reported causes
Input voltage below 185 V
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.
Note
Voltage figure from Arlington only

PU Capacitor charging circuit fault Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

U1 Compressor phase current sensing circuit fault Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

U3 DC bus voltage drop Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
Reported causes
Power supply problem
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

U7 Four-way valve fault Needs a technician

What it means
The valve that switches the unit between cooling and heating isn't changing over.
Reported causes
The valve doesn't change direction
What you can do
Try switching between cooling and heating once after restarting.
When to call a technician
If the code stays. The valve or its coil needs checking.

U9 AC zero-crossing detection error Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

C5 Jumper problem Needs a technician

What it means
A fault in the electronic control board or one of its parts.
Reported causes
Control board replaced without moving the jumper from the old one
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Sometimes the fault is temporary after a power fluctuation.
When to call a technician
If the code comes back. The board is tested and repaired or replaced; ask for a diagnosis before agreeing to replace it, as it is one of the most expensive parts.

Codes from a single source

We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.

EH Auxiliary heater fault Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
Reported causes
Stuck relay, unstable voltage, loose wire, moisture or rust
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

EU Frequency reduced because the IPM power module is hot Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

F7 Oil return in progress Not a fault

What it means
An operating status, not a fault. The unit is telling you what it is doing right now.
What you can do
Nothing. Wait until the code disappears by itself.
When to call a technician
If the code stays for hours or keeps appearing without a clear reason.
Note
The source describes it as normal operation

FC Sliding door problem Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

FE Compressor overload sensor fault Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

FH Frequency reduced by the anti-freeze limit Try it yourself first

What it means
The indoor coil got colder than it should and started to freeze, so the unit stopped the compressor to protect it.
What you can do
Clean the air filter, raise the fan speed, and don't set the temperature to the lowest setting for long periods. Leave the unit on fan mode until the ice melts.
When to call a technician
If the code keeps appearing with a clean filter, the refrigerant may be low or the fan weak.
Note
Arlington lists the same meaning under code Fb

H0 Frequency reduced because of high temperature in heating mode Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

H2 Electrostatic precipitator protection Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

HE Compressor demagnetisation protection Needs a technician

What it means
A problem running the compressor, the heart of the air conditioner.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back. Do not keep retrying, so the compressor is not damaged.

P0 Drive module reset problem Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

U2 Compressor phase loss protection Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

U4 Compressor reverse rotation protection Needs a technician

What it means
A problem running the compressor, the heart of the air conditioner.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back. Do not keep retrying, so the compressor is not damaged.

U5 AC current sensing circuit fault Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

U8 Discharge temperature sensor disconnected Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

oE PFC circuit overheating or its sensor fault Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

b5 Inlet pipe sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

b7 Outlet pipe sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.