E1 | High-pressure protection | Try it yourself first |
E2 | Freeze protection in cooling mode | Try it yourself first |
E3 | Low-pressure protection | Try it yourself first |
E4 | Compressor discharge high-temperature protection | Try it yourself first |
E5 | Overcurrent protection | Needs a technician |
E6 | Lost communication between the indoor and outdoor units | Try it yourself first |
E7 | Mode conflict | Try it yourself first |
E8 | Overheating protection, linked to the indoor fan or its board | Needs a technician |
EE | Board memory fault (EEPROM) | Needs a technician |
EH | Auxiliary heater fault | Needs a technician |
EU | Frequency reduced because the IPM power module is hot | Needs a technician |
F0 | Low refrigerant | Needs a technician |
F1 | Indoor room temperature sensor fault | Needs a technician |
F2 | Indoor evaporator sensor fault | Needs a technician |
F3 | Outdoor ambient temperature sensor fault | Needs a technician |
F4 | Outdoor pipe sensor fault | Needs a technician |
F5 | Discharge temperature sensor fault | Needs a technician |
F7 | Oil return in progress | Not a fault |
F9 | Frequency reduced because of high discharge temperature | Needs a technician |
FA | Frequency reduced because of high pipe temperature | Needs a technician |
FC | Sliding door problem | Needs a technician |
FE | Compressor overload sensor fault | Needs a technician |
FH | Frequency reduced by the anti-freeze limit | Try it yourself first |
H0 | Frequency reduced because of high temperature in heating mode | Needs a technician |
H1 | Defrost mode | Not a fault |
H2 | Electrostatic precipitator protection | Needs a technician |
H3 | Compressor overload protection | Needs a technician |
H4 | System overload or high pipe temperature | Try it yourself first |
H5 | IPM power module protection | Needs a technician |
H6 | Indoor fan motor not sending a signal | Needs a technician |
H7 | Compressor out of step (desynchronised) | Needs a technician |
HC | PFC circuit protection | Needs a technician |
HE | Compressor demagnetisation protection | Needs a technician |
L3 | Outdoor fan motor fault | Needs a technician |
L9 | Power protection | Needs a technician |
LC | Compressor failed to start | Needs a technician |
LD | Missing phase in the compressor supply | Needs a technician |
LE | Compressor stopped because it is locked | Needs a technician |
P0 | Drive module reset problem | Needs a technician |
P5 | Overcurrent protection on one compressor phase | Needs a technician |
P6 | Lost communication between the main board and the drive board | Needs a technician |
P7 | Power module temperature sensor circuit fault | Needs a technician |
P8 | Power module overheating protection | Needs a technician |
PA | Input overcurrent protection | Needs a technician |
PC | Current sensing circuit fault | Needs a technician |
PH | Overvoltage protection | Needs a technician |
PL | Undervoltage protection | Needs a technician |
PU | Capacitor charging circuit fault | Needs a technician |
U1 | Compressor phase current sensing circuit fault | Needs a technician |
U2 | Compressor phase loss protection | Needs a technician |
U3 | DC bus voltage drop | Needs a technician |
U4 | Compressor reverse rotation protection | Needs a technician |
U5 | AC current sensing circuit fault | Needs a technician |
U7 | Four-way valve fault | Needs a technician |
U8 | Discharge temperature sensor disconnected | Needs a technician |
U9 | AC zero-crossing detection error | Needs a technician |
C5 | Jumper problem | Needs a technician |
oE | PFC circuit overheating or its sensor fault | Needs a technician |
b5 | Inlet pipe sensor fault | Needs a technician |
b7 | Outlet pipe sensor fault | Needs a technician |