Code CH05 on an LG air conditioner: the indoor unit isn't communicating with the outdoor unit

This is what you see on the indoor unit's display. Usually CH and 05 appear alternately, and the unit doesn't cool.

Short answer

The two units exchange a signal over a wire between them, and CH05 means that signal is cut or disturbed. The cause may be temporary after a power fluctuation, clearing with a restart, or ongoing in the wiring or a board.

Is it dangerous?
No, but the unit won't cool
Does it clear by itself?
Sometimes after a restart
Can I fix it myself?
Try the steps, then call a technician

What to do now, in order

  1. Disconnect the power for 5 minutes

    at the breaker in the fuse box or by unplugging, then restore it. If the code disappears and doesn't return, it was a temporary glitch.

    Safe for you
  2. Make sure the outdoor unit has power

    If it has its own breaker, make sure it is on, and watch whether its fan turns when the unit starts.

    Safe for you
  3. Remember when the code started

    Right after installation? LG recommends contacting whoever installed the unit, because the fault is usually in the wiring. After a power cut or a storm? A damaged board becomes more likely.

    Safe for you
  4. Check the wire between the units by eye

    Look for cuts, burns or a taped joint in the middle of the visible cable. Don't open any cover.

    Safe for you

If the code returns after a restart, stop using the unit. Opening the terminal covers means dealing with live voltage.

Causes, from most to least likely

Temporary power glitch

A fluctuation or short outage disrupts communication and clears with a restart.

The connecting wire or its terminals

Most common

A loose terminal, a damaged wire, or the wrong wire order. Most likely if the code appeared after installation or relocation.

Loose connector inside one of the units

A wiring plug on the board has come out of place, usually from vibration.

Damaged control board

Indoor or outdoor. Suspected after ruling out the wiring, especially after a strong power fluctuation.

What to tell the technician

My LG inverter air conditioner shows code CH05. I disconnected the power for 5 minutes and the code came back, and the outdoor unit has power. I want the communication cable and its terminals checked before any board is replaced.

As with most communication faults, the wiring is cheaper and more common than the board.

Frequently asked questions

Are CH05, CH53 and E0 the same thing?

LG groups them all as a communication fault between the units and gives the same steps for them.

Does CH05 mean low refrigerant?

No. Low refrigerant has another code on LG units: CH38.

The code appeared right after installation. Who is responsible?

LG recommends going back to the installer, because the cause is usually in the wiring.