A5 on a Daikin air conditioner: freeze protection in coolingThis is what you see on the remote or the unit's display. The unit stops and the indoor unit's light blinks.
In cooling mode, A5 means the indoor evaporator got too cold and nearly froze, so the unit stopped itself. In heating mode it means high-pressure control. The most common cause in both cases is weak airflow from a dirty filter.
and if you see ice on the evaporator, let it melt completely before turning it on.
Safe for youwith lukewarm water and a soft brush, dry them in the shade, not in the sun, then put them back.
Safe for youno curtains or furniture blocking the indoor unit's air outlet or inlet.
Safe for youevery 3 to 6 months, especially in dusty areas.
Safe for youIf A5 returns with clean filters, the cause is usually the refrigerant or the coil sensor, and it needs a technician.
By far the most common. Weak airflow makes the evaporator cool down until it freezes.
Needs a deeper wash than the filter.
Makes the evaporator colder than normal.
Gives a wrong reading.
After ruling out the above.
My Daikin air conditioner shows code A5 in cooling mode. I washed the filters and the air flows freely, and the code came back. I would like the refrigerant charge and the indoor coil temperature sensor checked.
Say whether the code appeared in cooling or heating, because the meaning differs between them.
No, the unit is protecting itself from freezing. But if it keeps happening, there is a problem that needs fixing.
On some Daikin models: point the remote at the unit and hold the Cancel button until 00 appears, then press Cancel repeatedly and listen for the beep.
No, direct sunlight can warp it. Dry it in the shade.