Code F0 on a Gree air conditioner: low refrigerant (refrigerant protection)

This is what you see on the indoor unit's display. Cooling weakens, then the unit stops to protect itself.

Short answer

The unit went into protection mode because it sees the refrigerant is insufficient. Gree says most F0 cases are caused by the refrigerant amount: either the extra charge needed for long pipes wasn't added at installation, or there is a leak.

Is it dangerous?
For the compressor, if you ignore it
Does it clear by itself?
No
Can I fix it myself?
No, it needs a refrigeration technician

What to do now, in order

  1. Turn the unit off and disconnect the power for 10 minutes

    then restore it once. If F0 returns, the problem is real.

    Safe for you
  2. Remember when the code started

    Shortly after installation? Most likely the extra refrigerant for the pipe length wasn't added. After years? Most likely a leak.

    Safe for you
  3. Look at the pipe connections

    Oily spots around the nuts on both units usually point to the leak. Don't touch them.

    Safe for you
  4. Don't run the cooling before the repair

    Running repeatedly with low refrigerant strains the compressor.

    Safe for you

Recharging refrigerant and leak testing need tools and a licence. Don't attempt it yourself.

Causes, from most to least likely

Low refrigerant from installation

Most common

The extra amount required for the pipe length wasn't added. Gree lists this as the first cause.

Leak in the pipes or connections

Most likely if the code appeared after years of the unit working well.

Faulty evaporator temperature sensor

Gives a wrong reading, so the unit thinks the refrigerant is low.

Expansion valve or a blocked strainer

Less common; the technician checks it after the above.

What to tell the technician

My Gree air conditioner shows code F0. I disconnected the power for 10 minutes and the code came back. I want the refrigerant pressure measured and the leak found and repaired, not just a recharge.

Gree advises the technician to leak-test with nitrogen, then evacuate and charge by weight. Recharging without a repair means the code will come back.

Frequently asked questions

Does recharging alone solve the problem?

No. If there is a leak, the code will return within weeks. The leak must be found and fixed first.

Is F0 the same as E1?

No, almost the opposite: E1 is high pressure, F0 is low refrigerant.

Could the sensor be the cause?

Yes, a faulty evaporator temperature sensor can give F0 with a full charge. The technician measures it with a meter.