Code CH38 on an LG air conditioner: low refrigerant

This is what you see on the indoor unit's display. The unit stops cooling to protect the compressor.

Short answer

The unit stopped itself because the refrigerant (cooling gas) level is low, to protect the compressor from damage. Refrigerant isn't consumed, so a shortage usually means a leak in the pipes or connections.

Is it dangerous?
For the compressor, yes, if you ignore it
Does it clear by itself?
Rarely
Can I fix it myself?
No, it needs a refrigeration technician

What to do now, in order

  1. Disconnect the power for 5 minutes, once

    If the code appeared after the unit had run for a long time without problems, it may be a temporary electrical glitch. Restore the power and watch.

    Safe for you
  2. Note when the code appeared

    Right after installing or moving the unit? Most likely the refrigerant wasn't charged in the right amount, or a pipe connection is leaking.

    Safe for you
  3. Look at the pipe connections

    At the outdoor and indoor units: oily spots around the nuts usually show where the leak is. Don't touch or loosen the nuts.

    Safe for you
  4. Stop the unit if the code returns

    Running it repeatedly with low refrigerant strains the compressor, the most expensive part of the unit.

    Safe for you

Working on refrigerant and pipes needs tools and a licence. Don't try to add gas yourself.

Causes, from most to least likely

Leak at the pipe connections

Most common

A nut that isn't tight at the indoor or outdoor unit. The most common, especially after installation or relocation.

Not enough refrigerant at installation

If the code appeared in the first weeks after installation.

Broken pipe or punctured heat exchanger

Corrosion or impact. Leaks here are slower and harder to find.

Blocked electronic expansion valve

Can make the unit read low refrigerant even when it is there.

Temporary electrical glitch

If the code disappeared after a restart and didn't return.

What to tell the technician

My LG air conditioner shows code CH38. I restarted it after disconnecting the power for 5 minutes and the code came back. I want the leak found and repaired, not just a refrigerant recharge.

The last sentence is the most important: recharging without fixing the leak means the code will return in a few weeks and you will pay again.

Frequently asked questions

Is recharging the refrigerant enough?

No. Refrigerant in a sealed circuit isn't consumed. If it is low, there is a leak, and it must be found and repaired before recharging.

Is CH38 the same as CH05?

No. CH05 is a communication fault between the units, while CH38 is related to the refrigerant.

Can I use the unit for ventilation only?

Fan mode doesn't run the compressor, so it won't harm it. But don't run the cooling before the repair.