CH38 on an LG air conditioner: low refrigerantThis is what you see on the indoor unit's display. The unit stops cooling to protect the compressor.
The unit stopped itself because the refrigerant (cooling gas) level is low, to protect the compressor from damage. Refrigerant isn't consumed, so a shortage usually means a leak in the pipes or connections.
If the code appeared after the unit had run for a long time without problems, it may be a temporary electrical glitch. Restore the power and watch.
Safe for youRight after installing or moving the unit? Most likely the refrigerant wasn't charged in the right amount, or a pipe connection is leaking.
Safe for youAt the outdoor and indoor units: oily spots around the nuts usually show where the leak is. Don't touch or loosen the nuts.
Safe for youRunning it repeatedly with low refrigerant strains the compressor, the most expensive part of the unit.
Safe for youWorking on refrigerant and pipes needs tools and a licence. Don't try to add gas yourself.
A nut that isn't tight at the indoor or outdoor unit. The most common, especially after installation or relocation.
If the code appeared in the first weeks after installation.
Corrosion or impact. Leaks here are slower and harder to find.
Can make the unit read low refrigerant even when it is there.
If the code disappeared after a restart and didn't return.
My LG air conditioner shows code CH38. I restarted it after disconnecting the power for 5 minutes and the code came back. I want the leak found and repaired, not just a refrigerant recharge.
The last sentence is the most important: recharging without fixing the leak means the code will return in a few weeks and you will pay again.
No. Refrigerant in a sealed circuit isn't consumed. If it is low, there is a leak, and it must be found and repaired before recharging.
No. CH05 is a communication fault between the units, while CH38 is related to the refrigerant.
Fan mode doesn't run the compressor, so it won't harm it. But don't run the cooling before the repair.