العربية

Code E1 on a Midea air conditioner: communication fault between the units

This is what you see on the indoor unit's display. The unit stops working. On newer models the same fault shows as code EL 01.

Short answer

On most Midea inverter split units, E1 means the indoor and outdoor units aren't exchanging the signal properly, so the unit stops. The most common cause is the communication wire between them.

Is it dangerous?
No
Does it clear by itself?
Rarely
Can I fix it myself?
The first steps only

What to do now, in order

  1. Disconnect the power and restore it once

    at the breaker. If the code disappears and doesn't return, it was a temporary glitch. Don't keep switching off and on.

    Safe for you
  2. Make sure the breaker is fully on

    A half-tripped breaker can leave the indoor unit running and the outdoor unit without power.

    Safe for you
  3. Remember what came before the code

    A storm, a power cut, or a new installation? This information helps the technician.

    Safe for you
  4. Don't open the electrical cover

    on either the indoor or the outdoor unit.

    Safe for you

If E1 returns after one restart, the fault is in the wiring or a board and needs a technician.

Causes, from most to least likely

The communication wire between the units

Most common

Damaged, wired incorrectly, or extended with a joint. The most common.

Loose terminal

A loose screw on the terminal block.

Power problem

Low voltage or a half-tripped breaker.

Damaged indoor or outdoor control board

After ruling out the above, especially after a power fluctuation.

What to tell the technician

My Midea split air conditioner shows code E1. I disconnected and restored the power, the code came back, and the breaker is on. I want the communication wire between the units and its terminals checked before any board is replaced.

Mention the unit's year or model if you know it, because the meaning of E1 differs on very old models.

Frequently asked questions

Does E1 mean the same thing on all Midea units?

No. On old outdoor units from before 2012 it can mean a room temperature sensor fault, and on window and portable units it may be a filter-cleaning reminder.

What is EL 01?

It is the same communication fault between the units, on Midea inverter models from 2019 onwards.

Does E1 mean low refrigerant?

No, it is an electrical communication fault.

Other codes