Daikin air conditioner error codes

72 codes, each with what it means, what you can safely try yourself, and when to call a technician. The codes are a letter and a number, and can be read from the remote by holding the Cancel button.

57 of the 72 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
A1Indoor unit board faultNeeds a technician
A3Drain or float switch faultTry it yourself first
A5Freeze protection or high-pressure controlTry it yourself first
A6Indoor fan motor locked or overloadedNeeds a technician
C4Indoor heat exchanger sensor faultNeeds a technician
C9Return air temperature sensor faultNeeds a technician
E1Outdoor unit board faultNeeds a technician
E3High-pressure protectionTry it yourself first
E4Low-pressure protectionNeeds a technician
E5Compressor motor overloadNeeds a technician
E7Outdoor fan motor lockedNeeds a technician
EAFour-way valve faultNeeds a technician
L4Inverter heat sink overheatingTry it yourself first
U0Low refrigerantNeeds a technician
U4Indoor–outdoor unit communication faultTry it yourself first
A7Swing flap motor lockedNeeds a technician
E6Compressor motor lockedNeeds a technician
E8Inverter compressor overcurrentNeeds a technician
F3Abnormal discharge pipe temperatureNeeds a technician
F6Abnormal high pressure in coolingTry it yourself first
H0Compressor sensor faultNeeds a technician
H6Position detection sensor faultNeeds a technician
H9Outdoor ambient temperature sensor faultNeeds a technician
J3Discharge pipe sensor faultNeeds a technician
J6Outdoor heat exchanger sensor faultNeeds a technician
L3Abnormal electrical box temperatureNeeds a technician
L5Inverter compressor overcurrentNeeds a technician
P4Inverter heat sink temperature sensor faultNeeds a technician
U2Supply voltage problemNeeds a technician
A0External protection device activatedNeeds a technician
A4Freeze protection activatedTry it yourself first
A8Main power supply faultNeeds a technician
A9Electronic expansion valve failureNeeds a technician
AAHeater temperature above the limitNeeds a technician
AJWrong capacity setting or missing adaptorNeeds a technician
C1Transmission failure on the indoor unit boardNeeds a technician
C5Gas pipe sensor faultNeeds a technician
C6Fan motor driver not workingNeeds a technician
C7Front panel motor faultNeeds a technician
CAOutlet air sensor faultNeeds a technician
CCHumidity sensor faultNeeds a technician
CJRemote controller thermostat sensor not workingNeeds a technician
E0Outdoor unit safety device activatedNeeds a technician
H5Compressor motor overload sensor problemNeeds a technician
H7Outdoor fan motor not workingNeeds a technician
H8Compressor input faultNeeds a technician
J1Pressure sensor faultNeeds a technician
J2Compressor current sensor faultNeeds a technician
J4Low-pressure saturation temperature sensor faultNeeds a technician
J5Suction pipe sensor not workingNeeds a technician
JAHigh-pressure sensor not workingNeeds a technician
JCLow-pressure sensor faultNeeds a technician
JFOutdoor unit heating sensor faultNeeds a technician
L0Inverter system faultNeeds a technician
L1Inverter board faultNeeds a technician
L6Inverter instantaneous AC overcurrentNeeds a technician
L8Overvoltage on the inverter compressorNeeds a technician
L9Inverter compressor won't startNeeds a technician
LAPower transistor faultNeeds a technician
LCOutdoor main board communication failureNeeds a technician
P0Low refrigerant levelNeeds a technician
P1Unbalanced outdoor unit supply voltageNeeds a technician
P3Electrical box temperature sensor faultNeeds a technician
PJCapacity setting error or mismatchNeeds a technician
U1Reversed or missing phase in the supplyNeeds a technician
U3Transmission system faultNeeds a technician
U5Indoor unit to remote controller communication failureNeeds a technician
U6Transmission fault between indoor unitsNeeds a technician
U7Fault between the chassis processor and inverter processorNeeds a technician
U8Transmission stopped between remote controllersNeeds a technician
UAPower supply faultNeeds a technician
UJAccessory communication lostNeeds a technician

Every code explained

Everything under “What you can do” is done without opening any cover. Opening the air conditioner or measuring its wiring with the power on is a technician's job.

A1 Indoor unit board fault Needs a technician

What it means
A fault in the electronic control board or one of its parts.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Sometimes the fault is temporary after a power fluctuation.
When to call a technician
If the code comes back. The board is tested and repaired or replaced; ask for a diagnosis before agreeing to replace it, as it is one of the most expensive parts.

A3 Drain or float switch fault Try it yourself first

What it means
Condensate water isn't draining from the unit as it should, so the unit stopped itself to keep water from dripping into the room.
What you can do
Make sure the drain hose isn't kinked or blocked at its outer end, and that the indoor unit is level.
When to call a technician
If the hose looks fine from outside. An internal blockage or pump fault means opening the unit.

A5 Freeze protection or high-pressure control Try it yourself first

What it means
The indoor coil got colder than it should and started to freeze, so the unit stopped the compressor to protect it.
What you can do
Clean the air filter, raise the fan speed, and don't set the temperature to the lowest setting for long periods. Leave the unit on fan mode until the ice melts.
When to call a technician
If the code keeps appearing with a clean filter, the refrigerant may be low or the fan weak.
Detailed explanation
Causes in order, steps, and what to tell the technician →

A6 Indoor fan motor locked or overloaded Needs a technician

What it means
The fan is not turning, or it turns but the unit does not receive its rotation signal.
What you can do
Turn the unit off and check whether anything is blocking the fan: built-up dirt, a leaf or a foreign object. Never put your hand in while the power is on.
When to call a technician
If the fan turns freely but does not run. The motor, its capacitor or the board needs testing.

C4 Indoor heat exchanger sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

C9 Return air temperature sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

E1 Outdoor unit board fault Needs a technician

What it means
A fault in the electronic control board or one of its parts.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Sometimes the fault is temporary after a power fluctuation.
When to call a technician
If the code comes back. The board is tested and repaired or replaced; ask for a diagnosis before agreeing to replace it, as it is one of the most expensive parts.

E3 High-pressure protection Try it yourself first

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

E4 Low-pressure protection Needs a technician

What it means
There is less refrigerant in the system than needed, usually because of a leak.
What you can do
Clean the filter and confirm that cooling really is weak. There is nothing else to do on your side.
When to call a technician
In almost every case. Ask the technician to find and repair the leak before recharging; recharging alone is only a temporary fix.

E5 Compressor motor overload Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

E7 Outdoor fan motor locked Needs a technician

What it means
The fan is not turning, or it turns but the unit does not receive its rotation signal.
What you can do
Turn the unit off and check whether anything is blocking the fan: built-up dirt, a leaf or a foreign object. Never put your hand in while the power is on.
When to call a technician
If the fan turns freely but does not run. The motor, its capacitor or the board needs testing.

EA Four-way valve fault Needs a technician

What it means
The valve that switches the unit between cooling and heating isn't changing over.
What you can do
Try switching between cooling and heating once after restarting.
When to call a technician
If the code stays. The valve or its coil needs checking.

L4 Inverter heat sink overheating Try it yourself first

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

U0 Low refrigerant Needs a technician

What it means
There is less refrigerant in the system than needed, usually because of a leak.
What you can do
Clean the filter and confirm that cooling really is weak. There is nothing else to do on your side.
When to call a technician
In almost every case. Ask the technician to find and repair the leak before recharging; recharging alone is only a temporary fix.
Detailed explanation
Causes in order, steps, and what to tell the technician →

U4 Indoor–outdoor unit communication fault Try it yourself first

What it means
The indoor and outdoor units (or two boards inside the unit) exchange a signal over a wire, and that signal has been lost.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Make sure the outdoor unit's breaker is on. Note whether the code started after installation, relocation or a power cut.
When to call a technician
If the code comes back after restarting. Checking the cable and terminals is done with the power on, which is a technician's job.
Detailed explanation
Causes in order, steps, and what to tell the technician →

Codes from a single source

We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.

A7 Swing flap motor locked Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

E6 Compressor motor locked Needs a technician

What it means
A problem running the compressor, the heart of the air conditioner.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back. Do not keep retrying, so the compressor is not damaged.

E8 Inverter compressor overcurrent Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

F3 Abnormal discharge pipe temperature Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

F6 Abnormal high pressure in cooling Try it yourself first

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

H0 Compressor sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

H6 Position detection sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

H9 Outdoor ambient temperature sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

J3 Discharge pipe sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

J6 Outdoor heat exchanger sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

L3 Abnormal electrical box temperature Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

L5 Inverter compressor overcurrent Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

P4 Inverter heat sink temperature sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

U2 Supply voltage problem Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

A0 External protection device activated Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.
Note
This code and the ones after it are from the full list; some are for commercial systems

A4 Freeze protection activated Try it yourself first

What it means
The indoor coil got colder than it should and started to freeze, so the unit stopped the compressor to protect it.
What you can do
Clean the air filter, raise the fan speed, and don't set the temperature to the lowest setting for long periods. Leave the unit on fan mode until the ice melts.
When to call a technician
If the code keeps appearing with a clean filter, the refrigerant may be low or the fan weak.

A8 Main power supply fault Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

A9 Electronic expansion valve failure Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

AA Heater temperature above the limit Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

AJ Wrong capacity setting or missing adaptor Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

C1 Transmission failure on the indoor unit board Needs a technician

What it means
A fault in the electronic control board or one of its parts.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Sometimes the fault is temporary after a power fluctuation.
When to call a technician
If the code comes back. The board is tested and repaired or replaced; ask for a diagnosis before agreeing to replace it, as it is one of the most expensive parts.

C5 Gas pipe sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

C6 Fan motor driver not working Needs a technician

What it means
The fan is not turning, or it turns but the unit does not receive its rotation signal.
What you can do
Turn the unit off and check whether anything is blocking the fan: built-up dirt, a leaf or a foreign object. Never put your hand in while the power is on.
When to call a technician
If the fan turns freely but does not run. The motor, its capacitor or the board needs testing.

C7 Front panel motor fault Needs a technician

What it means
A fault in the electronic control board or one of its parts.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Sometimes the fault is temporary after a power fluctuation.
When to call a technician
If the code comes back. The board is tested and repaired or replaced; ask for a diagnosis before agreeing to replace it, as it is one of the most expensive parts.

CA Outlet air sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

CC Humidity sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

CJ Remote controller thermostat sensor not working Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

E0 Outdoor unit safety device activated Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

H5 Compressor motor overload sensor problem Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

H7 Outdoor fan motor not working Needs a technician

What it means
The fan is not turning, or it turns but the unit does not receive its rotation signal.
What you can do
Turn the unit off and check whether anything is blocking the fan: built-up dirt, a leaf or a foreign object. Never put your hand in while the power is on.
When to call a technician
If the fan turns freely but does not run. The motor, its capacitor or the board needs testing.

H8 Compressor input fault Needs a technician

What it means
A problem running the compressor, the heart of the air conditioner.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back. Do not keep retrying, so the compressor is not damaged.

J1 Pressure sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

J2 Compressor current sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

J4 Low-pressure saturation temperature sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

J5 Suction pipe sensor not working Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

JA High-pressure sensor not working Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

JC Low-pressure sensor fault Needs a technician

What it means
There is less refrigerant in the system than needed, usually because of a leak.
What you can do
Clean the filter and confirm that cooling really is weak. There is nothing else to do on your side.
When to call a technician
In almost every case. Ask the technician to find and repair the leak before recharging; recharging alone is only a temporary fix.

JF Outdoor unit heating sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

L0 Inverter system fault Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

L1 Inverter board fault Needs a technician

What it means
A fault in the electronic control board or one of its parts.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Sometimes the fault is temporary after a power fluctuation.
When to call a technician
If the code comes back. The board is tested and repaired or replaced; ask for a diagnosis before agreeing to replace it, as it is one of the most expensive parts.

L6 Inverter instantaneous AC overcurrent Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

L8 Overvoltage on the inverter compressor Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

L9 Inverter compressor won't start Needs a technician

What it means
A problem running the compressor, the heart of the air conditioner.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back. Do not keep retrying, so the compressor is not damaged.

LA Power transistor fault Needs a technician

What it means
A fault in the electronic control board or one of its parts.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Sometimes the fault is temporary after a power fluctuation.
When to call a technician
If the code comes back. The board is tested and repaired or replaced; ask for a diagnosis before agreeing to replace it, as it is one of the most expensive parts.

LC Outdoor main board communication failure Needs a technician

What it means
The indoor and outdoor units (or two boards inside the unit) exchange a signal over a wire, and that signal has been lost.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Make sure the outdoor unit's breaker is on. Note whether the code started after installation, relocation or a power cut.
When to call a technician
If the code comes back after restarting. Checking the cable and terminals is done with the power on, which is a technician's job.

P0 Low refrigerant level Needs a technician

What it means
There is less refrigerant in the system than needed, usually because of a leak.
What you can do
Clean the filter and confirm that cooling really is weak. There is nothing else to do on your side.
When to call a technician
In almost every case. Ask the technician to find and repair the leak before recharging; recharging alone is only a temporary fix.

P1 Unbalanced outdoor unit supply voltage Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

P3 Electrical box temperature sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

PJ Capacity setting error or mismatch Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

U1 Reversed or missing phase in the supply Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

U3 Transmission system fault Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

U5 Indoor unit to remote controller communication failure Needs a technician

What it means
The indoor and outdoor units (or two boards inside the unit) exchange a signal over a wire, and that signal has been lost.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Make sure the outdoor unit's breaker is on. Note whether the code started after installation, relocation or a power cut.
When to call a technician
If the code comes back after restarting. Checking the cable and terminals is done with the power on, which is a technician's job.

U6 Transmission fault between indoor units Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

U7 Fault between the chassis processor and inverter processor Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

U8 Transmission stopped between remote controllers Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

UA Power supply fault Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

UJ Accessory communication lost Needs a technician

What it means
The indoor and outdoor units (or two boards inside the unit) exchange a signal over a wire, and that signal has been lost.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Make sure the outdoor unit's breaker is on. Note whether the code started after installation, relocation or a power cut.
When to call a technician
If the code comes back after restarting. Checking the cable and terminals is done with the power on, which is a technician's job.

Sources