العربية

Code E6 on a Gree air conditioner: the indoor unit isn't communicating with the outdoor unit

This is what you see on the indoor unit's display. The unit stops cooling, and may run for a few minutes before the code returns.

Short answer

The indoor and outdoor units exchange a signal over a wire between them. When E6 appears, that signal has been cut. In most cases the cause is the connecting wire itself, not a damaged part inside the unit.

Is it dangerous?
No, but the unit won't cool
Does it clear by itself?
No, it stays until the cause is fixed
Can I fix it myself?
Try the four steps, then call a technician

What to do now, in order

  1. Disconnect the power for five minutes, then restart

    at the breaker in the fuse box, not with the remote. If the code returns, the problem is still there, and switching off again won't solve it.

    Safe for you
  2. Make sure the outdoor unit has power

    Some installations give the outdoor unit its own breaker. Check that it is on, and whether the outdoor fan turns when the unit starts.

    Safe for you
  3. Remember when the code started

    After a new installation or moving the unit? Most likely a wiring mistake. After a power cut or a thunderstorm? A damaged control board becomes more likely. This information saves the technician half the diagnosis.

    Safe for you
  4. Check the wire by eye only

    Follow the visible cable between the units: cuts, burns, rodent damage, or a joint taped up in the middle. Don't open any cover.

    Safe for you

Stop here. Opening the terminal cover or measuring the wires means dealing with live voltage, which is a technician's job.

Causes, from most to least likely

Wrong wire, or a wire joined from two pieces

Most common

According to Gree's technical team, this causes communication loss more often than any faulty part. It happens when an unsuitable cable is used or the cable is extended with a joint.

Loose terminals or wires in the wrong order

A loose screw on the terminal block, or the wire order in the indoor unit doesn't match the outdoor unit.

Damaged cable

Wear from sun and heat, rodent damage, or a sharp bend inside the wall.

Earthing problem or electrical interference

Poor earthing disturbs the signal between the units.

Damaged indoor or outdoor control board

Suspected after ruling out everything above, especially if the code started after a power fluctuation.

Reversed phase order

Only on units that run on three-phase power (380 V).

What to tell the technician

My Gree split air conditioner shows code E6. I switched it off at the breaker and restarted it, and the code came back. I want the communication cable between the units and the terminals checked before any board is replaced.

The last sentence matters: replacing the board is the most expensive repair, and the most common cause is far cheaper.

Frequently asked questions

The code appears and disappears. Is that normal?

Yes, at first. The fault can be intermittent at the beginning, like a loose terminal that only touches sometimes, and then becomes permanent.

Can I clear the code from the remote?

No. The code can't be cleared or reset until the cause itself is fixed.

Does E6 mean the refrigerant is low?

No. Low refrigerant has another code on Gree units: F0.