Home ‹ Industrial drives ‹ Yaskawa
Yaskawa drive error codes
21 codes, each with what it means, what you can safely try yourself, and when to call a technician.
12 of the 21 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.
A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.
Quick table
| Code | Meaning | Who handles it |
|---|
OC | Output overcurrent | Needs a technician |
GF | Output earth fault | Needs a technician |
OV | DC bus overvoltage | Needs a technician |
UV1 | DC bus undervoltage | Needs a technician |
OL1 | Motor overload | Needs a technician |
OL2 | Drive overload | Needs a technician |
PF | Input phase loss | Needs a technician |
LF | Output phase loss | Needs a technician |
CE | Communication error | Needs a technician |
EF | Forward and reverse run commands at the same time | Needs a technician |
EF1 | External fault on input S1 | Needs a technician |
EF2 | External fault on input S2 | Needs a technician |
EF3 | External fault on input S3 | Needs a technician |
EF4 | External fault on input S4 | Needs a technician |
EF5 | External fault on input S5 | Needs a technician |
EF6 | External fault on input S6 | Needs a technician |
EF7 | External fault on input S7 | Needs a technician |
EF8 | External fault on input S8 | Needs a technician |
Hbb | Safe stop inputs open | Needs a technician |
bUS | Network communication card lost | Needs a technician |
oPE | Programming error, conflicting settings | Needs a technician |
Every code explained
Drive capacitors hold a lethal voltage for minutes after the supply is disconnected. Wait for the charge light to go out and measure the voltage before touching any terminal.
OC Output overcurrent Needs a technician
- What it means
- The current suddenly rose above the drive's limit: a heavy load, acceleration that is too fast, or a short in the motor or its cable.
- What the source says
- Short circuit, jam, or a short acceleration time
- What you can do
- Make sure the mechanical load isn't jammed and turns by hand, then stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
- When to call a technician
- If the code comes back. The acceleration or deceleration time is increased, and the motor and its cable are insulation-tested.
- Note
- V1000 and A1000 series
GF Output earth fault Needs a technician
- What it means
- Current is leaking from one of the output phases to earth, usually from the motor cable or windings.
- What the source says
- Damaged motor or cable insulation
- What you can do
- Disconnect the supply and don't keep restarting.
- When to call a technician
- In every case. The insulation of the motor cable and windings is measured with a megger after disconnecting them from the drive.
OV DC bus overvoltage Needs a technician
- What it means
- The DC bus voltage inside the drive rose above the limit. It usually happens when stopping a high-inertia load quickly, or with a high supply voltage.
- What the source says
- Fast deceleration
- What you can do
- Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
- When to call a technician
- If it keeps happening. The deceleration time is increased or a braking resistor fitted, and the supply voltage is measured.
UV1 DC bus undervoltage Needs a technician
- What it means
- The supply reaching the drive is deficient: low voltage, a missing phase, or a momentary dip.
- What the source says
- Supply dip or a loose connection
- What you can do
- Make sure the breaker and fuses ahead of the drive are sound and all three phases are present.
- When to call a technician
- If the supply is sound and the code stays. The charging circuit and capacitors inside the drive are checked.
OL1 Motor overload Needs a technician
- What it means
- The motor or drive is running above its rated current for longer than allowed.
- What you can do
- Reduce the load, and make sure the machine isn't jammed and the motor's ventilation isn't blocked.
- When to call a technician
- If it keeps happening with a normal load. The motor current value entered in the settings and the drive's size are reviewed.
OL2 Drive overload Needs a technician
- What it means
- The motor or drive is running above its rated current for longer than allowed.
- What you can do
- Reduce the load, and make sure the machine isn't jammed and the motor's ventilation isn't blocked.
- When to call a technician
- If it keeps happening with a normal load. The motor current value entered in the settings and the drive's size are reviewed.
PF Input phase loss Needs a technician
- What it means
- The supply reaching the drive is deficient: low voltage, a missing phase, or a momentary dip.
- What the source says
- Blown fuse or a loose terminal
- What you can do
- Make sure the breaker and fuses ahead of the drive are sound and all three phases are present.
- When to call a technician
- If the supply is sound and the code stays. The charging circuit and capacitors inside the drive are checked.
LF Output phase loss Needs a technician
- What it means
- One of the three phases between the drive and the motor is broken or unbalanced.
- What you can do
- Disconnect the supply and don't run the motor on two phases.
- When to call a technician
- In every case. The motor cable terminals are checked at the drive and at the motor, and any contactor between them.
CE Communication error Needs a technician
- What it means
- The drive lost contact with its keypad or with the controller that sends it commands.
- What you can do
- Make sure the communication cable and the keypad are seated properly.
- When to call a technician
- If the code stays. The communication settings, address and speed are reviewed, and the cable is checked for interference.
Codes from a single source
We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.
EF Forward and reverse run commands at the same time Needs a technician
- What it means
- An internal drive fault: memory, processor or one of the circuits.
- What you can do
- Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
- When to call a technician
- If the code comes back. It may need a factory reset or a board replacement.
EF1 External fault on input S1 Needs a technician
- What it means
- An external input is preventing operation: an open safety circuit, an emergency stop, or a fault signal from another device.
- What you can do
- Make sure the emergency stop is released and the guard doors are closed.
- When to call a technician
- If the safety circuit is sound and the code stays.
EF2 External fault on input S2 Needs a technician
- What it means
- An external input is preventing operation: an open safety circuit, an emergency stop, or a fault signal from another device.
- What you can do
- Make sure the emergency stop is released and the guard doors are closed.
- When to call a technician
- If the safety circuit is sound and the code stays.
EF3 External fault on input S3 Needs a technician
- What it means
- An external input is preventing operation: an open safety circuit, an emergency stop, or a fault signal from another device.
- What you can do
- Make sure the emergency stop is released and the guard doors are closed.
- When to call a technician
- If the safety circuit is sound and the code stays.
EF4 External fault on input S4 Needs a technician
- What it means
- An external input is preventing operation: an open safety circuit, an emergency stop, or a fault signal from another device.
- What you can do
- Make sure the emergency stop is released and the guard doors are closed.
- When to call a technician
- If the safety circuit is sound and the code stays.
EF5 External fault on input S5 Needs a technician
- What it means
- An external input is preventing operation: an open safety circuit, an emergency stop, or a fault signal from another device.
- What you can do
- Make sure the emergency stop is released and the guard doors are closed.
- When to call a technician
- If the safety circuit is sound and the code stays.
EF6 External fault on input S6 Needs a technician
- What it means
- An external input is preventing operation: an open safety circuit, an emergency stop, or a fault signal from another device.
- What you can do
- Make sure the emergency stop is released and the guard doors are closed.
- When to call a technician
- If the safety circuit is sound and the code stays.
EF7 External fault on input S7 Needs a technician
- What it means
- An external input is preventing operation: an open safety circuit, an emergency stop, or a fault signal from another device.
- What you can do
- Make sure the emergency stop is released and the guard doors are closed.
- When to call a technician
- If the safety circuit is sound and the code stays.
EF8 External fault on input S8 Needs a technician
- What it means
- An external input is preventing operation: an open safety circuit, an emergency stop, or a fault signal from another device.
- What you can do
- Make sure the emergency stop is released and the guard doors are closed.
- When to call a technician
- If the safety circuit is sound and the code stays.
Hbb Safe stop inputs open Needs a technician
- What it means
- An internal drive fault: memory, processor or one of the circuits.
- What you can do
- Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
- When to call a technician
- If the code comes back. It may need a factory reset or a board replacement.
bUS Network communication card lost Needs a technician
- What it means
- The drive lost contact with its keypad or with the controller that sends it commands.
- What you can do
- Make sure the communication cable and the keypad are seated properly.
- When to call a technician
- If the code stays. The communication settings, address and speed are reviewed, and the cable is checked for interference.
oPE Programming error, conflicting settings Needs a technician
- What it means
- An internal drive fault: memory, processor or one of the circuits.
- What you can do
- Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
- When to call a technician
- If the code comes back. It may need a factory reset or a board replacement.