Schneider drive error codes

24 codes, each with what it means, what you can safely try yourself, and when to call a technician.

All the codes on this page come from a single unofficial source, and we have not yet found a second one confirming them. Treat them as a first hint and check them against your appliance's manual before any repair.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
OCFOvercurrentNeeds a technician
OBFDC bus overvoltageNeeds a technician
OSFSupply voltage highNeeds a technician
USFUndervoltageNeeds a technician
PHFInput phase lossNeeds a technician
OPF1Output phase lossNeeds a technician
OPF2Output phase lossNeeds a technician
OLFMotor overloadNeeds a technician
OHFDrive overheatingNeeds a technician
SCF1Motor short circuitNeeds a technician
SCF3Short circuit to earthNeeds a technician
SCF4IGBT short circuit inside the driveNeeds a technician
SCF5Short circuit in the motor or the loadNeeds a technician
SOFOverspeedNeeds a technician
CrFPre-charge faultNeeds a technician
LFF1Loss of the 4-20 mA signal on AI1Needs a technician
LFF3Loss of the 4-20 mA signal on AI3Needs a technician
tnFAuto-tuning failedNeeds a technician
EEF1Control board memory faultNeeds a technician
EEF2Power board memory faultNeeds a technician
SLF1Modbus communication lostNeeds a technician
SLF2Lost connection to the PC softwareNeeds a technician
SLF3Lost connection to the remote keypadNeeds a technician
InFInternal faultNeeds a technician

Every code explained

Drive capacitors hold a lethal voltage for minutes after the supply is disconnected. Wait for the charge light to go out and measure the voltage before touching any terminal.

OCF Overcurrent Needs a technician

What it means
The current suddenly rose above the drive's limit: a heavy load, acceleration that is too fast, or a short in the motor or its cable.
What the source says
Output current exceeded the limit
What you can do
Make sure the mechanical load isn't jammed and turns by hand, then stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. The acceleration or deceleration time is increased, and the motor and its cable are insulation-tested.
Note
Altivar series

OBF DC bus overvoltage Needs a technician

What it means
The DC bus voltage inside the drive rose above the limit. It usually happens when stopping a high-inertia load quickly, or with a high supply voltage.
What the source says
Fast deceleration with a high-inertia load
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If it keeps happening. The deceleration time is increased or a braking resistor fitted, and the supply voltage is measured.

OSF Supply voltage high Needs a technician

What it means
The supply reaching the drive is deficient: low voltage, a missing phase, or a momentary dip.
What you can do
Make sure the breaker and fuses ahead of the drive are sound and all three phases are present.
When to call a technician
If the supply is sound and the code stays. The charging circuit and capacitors inside the drive are checked.

USF Undervoltage Needs a technician

What it means
The supply reaching the drive is deficient: low voltage, a missing phase, or a momentary dip.
What you can do
Make sure the breaker and fuses ahead of the drive are sound and all three phases are present.
When to call a technician
If the supply is sound and the code stays. The charging circuit and capacitors inside the drive are checked.

PHF Input phase loss Needs a technician

What it means
The supply reaching the drive is deficient: low voltage, a missing phase, or a momentary dip.
What you can do
Make sure the breaker and fuses ahead of the drive are sound and all three phases are present.
When to call a technician
If the supply is sound and the code stays. The charging circuit and capacitors inside the drive are checked.

OPF1 Output phase loss Needs a technician

What it means
One of the three phases between the drive and the motor is broken or unbalanced.
What you can do
Disconnect the supply and don't run the motor on two phases.
When to call a technician
In every case. The motor cable terminals are checked at the drive and at the motor, and any contactor between them.

OPF2 Output phase loss Needs a technician

What it means
One of the three phases between the drive and the motor is broken or unbalanced.
What you can do
Disconnect the supply and don't run the motor on two phases.
When to call a technician
In every case. The motor cable terminals are checked at the drive and at the motor, and any contactor between them.

OLF Motor overload Needs a technician

What it means
The motor or drive is running above its rated current for longer than allowed.
What you can do
Reduce the load, and make sure the machine isn't jammed and the motor's ventilation isn't blocked.
When to call a technician
If it keeps happening with a normal load. The motor current value entered in the settings and the drive's size are reviewed.

OHF Drive overheating Needs a technician

What it means
The drive or motor temperature is outside the allowed limit.
What the source says
Blocked cooling
What you can do
Clean the dust off the panel filters and the drive's heat sink, and make sure its fan turns and the room temperature is acceptable.
When to call a technician
If the code stays with good ventilation. The fan or the temperature sensor is replaced.

SCF1 Motor short circuit Needs a technician

What it means
The current suddenly rose above the drive's limit: a heavy load, acceleration that is too fast, or a short in the motor or its cable.
What you can do
Make sure the mechanical load isn't jammed and turns by hand, then stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. The acceleration or deceleration time is increased, and the motor and its cable are insulation-tested.

SCF3 Short circuit to earth Needs a technician

What it means
Current is leaking from one of the output phases to earth, usually from the motor cable or windings.
What you can do
Disconnect the supply and don't keep restarting.
When to call a technician
In every case. The insulation of the motor cable and windings is measured with a megger after disconnecting them from the drive.

SCF4 IGBT short circuit inside the drive Needs a technician

What it means
The current suddenly rose above the drive's limit: a heavy load, acceleration that is too fast, or a short in the motor or its cable.
What you can do
Make sure the mechanical load isn't jammed and turns by hand, then stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. The acceleration or deceleration time is increased, and the motor and its cable are insulation-tested.

SCF5 Short circuit in the motor or the load Needs a technician

What it means
The current suddenly rose above the drive's limit: a heavy load, acceleration that is too fast, or a short in the motor or its cable.
What you can do
Make sure the mechanical load isn't jammed and turns by hand, then stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. The acceleration or deceleration time is increased, and the motor and its cable are insulation-tested.

SOF Overspeed Needs a technician

What it means
The motor's actual speed doesn't match what the drive is asking for, or the rotation sensor signal is lost.
What you can do
Make sure the load isn't jammed, then stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. The encoder, its cable and the control settings are checked.

CrF Pre-charge fault Needs a technician

What it means
The supply reaching the drive is deficient: low voltage, a missing phase, or a momentary dip.
What you can do
Make sure the breaker and fuses ahead of the drive are sound and all three phases are present.
When to call a technician
If the supply is sound and the code stays. The charging circuit and capacitors inside the drive are checked.

LFF1 Loss of the 4-20 mA signal on AI1 Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.

LFF3 Loss of the 4-20 mA signal on AI3 Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.

tnF Auto-tuning failed Needs a technician

What it means
The drive couldn't measure the motor's characteristics during auto-tuning.
What you can do
Make sure the motor is connected and unloaded, and its nameplate data is entered correctly, then repeat the tuning.
When to call a technician
If it fails again.

EEF1 Control board memory fault Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.

EEF2 Power board memory fault Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.

SLF1 Modbus communication lost Needs a technician

What it means
The drive lost contact with its keypad or with the controller that sends it commands.
What you can do
Make sure the communication cable and the keypad are seated properly.
When to call a technician
If the code stays. The communication settings, address and speed are reviewed, and the cable is checked for interference.

SLF2 Lost connection to the PC software Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.

SLF3 Lost connection to the remote keypad Needs a technician

What it means
The drive lost contact with its keypad or with the controller that sends it commands.
What you can do
Make sure the communication cable and the keypad are seated properly.
When to call a technician
If the code stays. The communication settings, address and speed are reviewed, and the cable is checked for interference.

InF Internal fault Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.