A3tali

Home ‹ Industrial drives ‹ Invertek

Invertek drive error codes

12 codes, each with what it means, what you can safely try yourself, and when to call a technician. Codes for the Optidrive series.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
F01The memory isn't saving the new settingNeeds a technician
F02Output current above 200% of ratedNeeds a technician
F03Current above 100% for a long timeNeeds a technician
F04Internal electronics overload protectionNeeds a technician
F05DC bus overvoltageNeeds a technician
F06DC bus undervoltageNeeds a technician
F07Heat sink overheatingNeeds a technician
F08Heat sink below the minimum temperatureNeeds a technician
F09Heat sink thermistor faultNeeds a technician
F10Communication lostNeeds a technician
F11Input phase lossNeeds a technician
F12Phase imbalanceNeeds a technician

Every code explained

Drive capacitors hold a lethal voltage for minutes after the supply is disconnected. Wait for the charge light to go out and measure the voltage before touching any terminal.

F01 The memory isn't saving the new setting Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.
Note
Optidrive series

F02 Output current above 200% of rated Needs a technician

What it means
The current suddenly rose above the drive's limit: a heavy load, acceleration that is too fast, or a short in the motor or its cable.
What you can do
Make sure the mechanical load isn't jammed and turns by hand, then stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. The acceleration or deceleration time is increased, and the motor and its cable are insulation-tested.

F03 Current above 100% for a long time Needs a technician

What it means
The motor or drive is running above its rated current for longer than allowed.
What you can do
Reduce the load, and make sure the machine isn't jammed and the motor's ventilation isn't blocked.
When to call a technician
If it keeps happening with a normal load. The motor current value entered in the settings and the drive's size are reviewed.

F04 Internal electronics overload protection Needs a technician

What it means
The motor or drive is running above its rated current for longer than allowed.
What you can do
Reduce the load, and make sure the machine isn't jammed and the motor's ventilation isn't blocked.
When to call a technician
If it keeps happening with a normal load. The motor current value entered in the settings and the drive's size are reviewed.

F05 DC bus overvoltage Needs a technician

What it means
The DC bus voltage inside the drive rose above the limit. It usually happens when stopping a high-inertia load quickly, or with a high supply voltage.
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If it keeps happening. The deceleration time is increased or a braking resistor fitted, and the supply voltage is measured.

F06 DC bus undervoltage Needs a technician

What it means
The supply reaching the drive is deficient: low voltage, a missing phase, or a momentary dip.
What you can do
Make sure the breaker and fuses ahead of the drive are sound and all three phases are present.
When to call a technician
If the supply is sound and the code stays. The charging circuit and capacitors inside the drive are checked.

F07 Heat sink overheating Needs a technician

What it means
The drive or motor temperature is outside the allowed limit.
What you can do
Clean the dust off the panel filters and the drive's heat sink, and make sure its fan turns and the room temperature is acceptable.
When to call a technician
If the code stays with good ventilation. The fan or the temperature sensor is replaced.

F08 Heat sink below the minimum temperature Needs a technician

What it means
The drive or motor temperature is outside the allowed limit.
What you can do
Clean the dust off the panel filters and the drive's heat sink, and make sure its fan turns and the room temperature is acceptable.
When to call a technician
If the code stays with good ventilation. The fan or the temperature sensor is replaced.

F09 Heat sink thermistor fault Needs a technician

What it means
The drive or motor temperature is outside the allowed limit.
What you can do
Clean the dust off the panel filters and the drive's heat sink, and make sure its fan turns and the room temperature is acceptable.
When to call a technician
If the code stays with good ventilation. The fan or the temperature sensor is replaced.

F10 Communication lost Needs a technician

What it means
The drive lost contact with its keypad or with the controller that sends it commands.
What you can do
Make sure the communication cable and the keypad are seated properly.
When to call a technician
If the code stays. The communication settings, address and speed are reviewed, and the cable is checked for interference.

F11 Input phase loss Needs a technician

What it means
The supply reaching the drive is deficient: low voltage, a missing phase, or a momentary dip.
What you can do
Make sure the breaker and fuses ahead of the drive are sound and all three phases are present.
When to call a technician
If the supply is sound and the code stays. The charging circuit and capacitors inside the drive are checked.

F12 Phase imbalance Needs a technician

What it means
The supply reaching the drive is deficient: low voltage, a missing phase, or a momentary dip.
What you can do
Make sure the breaker and fuses ahead of the drive are sound and all three phases are present.
When to call a technician
If the supply is sound and the code stays. The charging circuit and capacitors inside the drive are checked.

Sources