Danfoss drive error codes

17 codes, each with what it means, what you can safely try yourself, and when to call a technician.

10 of the 17 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
2Live zero errorNeeds a technician
4Mains phase lossNeeds a technician
7DC overvoltageNeeds a technician
8DC undervoltageNeeds a technician
9Drive overloadNeeds a technician
10Motor overheating per the ETR thermal modelNeeds a technician
11Motor overheating per the thermistorNeeds a technician
12Torque limitNeeds a technician
13OvercurrentNeeds a technician
14Earth faultNeeds a technician
16Short circuitNeeds a technician
17Control word timeoutNeeds a technician
29Heat sink overheatingNeeds a technician
30Motor phase U missingNeeds a technician
31Motor phase V missingNeeds a technician
32Motor phase W missingNeeds a technician
38Internal faultNeeds a technician

Every code explained

Drive capacitors hold a lethal voltage for minutes after the supply is disconnected. Wait for the charge light to go out and measure the voltage before touching any terminal.

2 Live zero error Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What the source says
Loss of the 4-20 mA reference signal
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.
Note
VLT series

4 Mains phase loss Needs a technician

What it means
The supply reaching the drive is deficient: low voltage, a missing phase, or a momentary dip.
What you can do
Make sure the breaker and fuses ahead of the drive are sound and all three phases are present.
When to call a technician
If the supply is sound and the code stays. The charging circuit and capacitors inside the drive are checked.

9 Drive overload Needs a technician

What it means
The motor or drive is running above its rated current for longer than allowed.
What you can do
Reduce the load, and make sure the machine isn't jammed and the motor's ventilation isn't blocked.
When to call a technician
If it keeps happening with a normal load. The motor current value entered in the settings and the drive's size are reviewed.

13 Overcurrent Needs a technician

What it means
The current suddenly rose above the drive's limit: a heavy load, acceleration that is too fast, or a short in the motor or its cable.
What you can do
Make sure the mechanical load isn't jammed and turns by hand, then stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. The acceleration or deceleration time is increased, and the motor and its cable are insulation-tested.

14 Earth fault Needs a technician

What it means
Current is leaking from one of the output phases to earth, usually from the motor cable or windings.
What you can do
Disconnect the supply and don't keep restarting.
When to call a technician
In every case. The insulation of the motor cable and windings is measured with a megger after disconnecting them from the drive.

16 Short circuit Needs a technician

What it means
The current suddenly rose above the drive's limit: a heavy load, acceleration that is too fast, or a short in the motor or its cable.
What you can do
Make sure the mechanical load isn't jammed and turns by hand, then stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. The acceleration or deceleration time is increased, and the motor and its cable are insulation-tested.

29 Heat sink overheating Needs a technician

What it means
The drive or motor temperature is outside the allowed limit.
What you can do
Clean the dust off the panel filters and the drive's heat sink, and make sure its fan turns and the room temperature is acceptable.
When to call a technician
If the code stays with good ventilation. The fan or the temperature sensor is replaced.

Codes from a single source

We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.

7 DC overvoltage Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What the source says
Fast deceleration or a supply rise
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.

8 DC undervoltage Needs a technician

What it means
The supply reaching the drive is deficient: low voltage, a missing phase, or a momentary dip.
What you can do
Make sure the breaker and fuses ahead of the drive are sound and all three phases are present.
When to call a technician
If the supply is sound and the code stays. The charging circuit and capacitors inside the drive are checked.

10 Motor overheating per the ETR thermal model Needs a technician

What it means
The drive or motor temperature is outside the allowed limit.
What you can do
Clean the dust off the panel filters and the drive's heat sink, and make sure its fan turns and the room temperature is acceptable.
When to call a technician
If the code stays with good ventilation. The fan or the temperature sensor is replaced.

11 Motor overheating per the thermistor Needs a technician

What it means
The drive or motor temperature is outside the allowed limit.
What you can do
Clean the dust off the panel filters and the drive's heat sink, and make sure its fan turns and the room temperature is acceptable.
When to call a technician
If the code stays with good ventilation. The fan or the temperature sensor is replaced.

12 Torque limit Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.

17 Control word timeout Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What the source says
Fieldbus signal stopped updating
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.

30 Motor phase U missing Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.

31 Motor phase V missing Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.

32 Motor phase W missing Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.

38 Internal fault Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.

Sources