A3tali

Home ‹ Industrial drives ‹ Allen-Bradley

Allen-Bradley drive error codes

23 codes, each with what it means, what you can safely try yourself, and when to call a technician. Codes for the PowerFlex 525 series, starting with F followed by three digits.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
F002Auxiliary inputNeeds a technician
F003Power lossNeeds a technician
F004UndervoltageNeeds a technician
F005OvervoltageNeeds a technician
F006Motor stalledNeeds a technician
F007Motor overloadNeeds a technician
F008Heat sink overheatingNeeds a technician
F009Control module overheatingNeeds a technician
F012Overcurrent (hardware)Needs a technician
F013Earth faultNeeds a technician
F015Load lossNeeds a technician
F021Output phase lossNeeds a technician
F029Analogue input lossNeeds a technician
F033Auto-restart attempts exhaustedNeeds a technician
F038Phase U to earthNeeds a technician
F039Phase V to earthNeeds a technician
F040Phase W to earthNeeds a technician
F048Parameters reset to factory defaultsNeeds a technician
F059Safety circuit openNeeds a technician
F064Drive overloadNeeds a technician
F070Power section faultNeeds a technician
F071DSI network lossNeeds a technician
F073EtherNet/IP lossNeeds a technician

Every code explained

Drive capacitors hold a lethal voltage for minutes after the supply is disconnected. Wait for the charge light to go out and measure the voltage before touching any terminal.

F002 Auxiliary input Needs a technician

What it means
An external input programmed to stop the drive was activated.
What the source says
External trip or interlock open
What you can do
Find the device connected to this input: a sensor, a protection relay, or a button.
When to call a technician
If the source of the signal can't be identified.
Note
PowerFlex 525 model

F003 Power loss Needs a technician

What it means
The supply reaching the drive is deficient: low voltage, a missing phase, or a momentary dip.
What you can do
Make sure the breaker and fuses ahead of the drive are sound and all three phases are present.
When to call a technician
If the supply is sound and the code stays. The charging circuit and capacitors inside the drive are checked.

F004 Undervoltage Needs a technician

What it means
The supply reaching the drive is deficient: low voltage, a missing phase, or a momentary dip.
What you can do
Make sure the breaker and fuses ahead of the drive are sound and all three phases are present.
When to call a technician
If the supply is sound and the code stays. The charging circuit and capacitors inside the drive are checked.

F005 Overvoltage Needs a technician

What it means
The DC bus voltage inside the drive rose above the limit. It usually happens when stopping a high-inertia load quickly, or with a high supply voltage.
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If it keeps happening. The deceleration time is increased or a braking resistor fitted, and the supply voltage is measured.

F006 Motor stalled Needs a technician

What it means
The motor or drive is running above its rated current for longer than allowed.
What you can do
Reduce the load, and make sure the machine isn't jammed and the motor's ventilation isn't blocked.
When to call a technician
If it keeps happening with a normal load. The motor current value entered in the settings and the drive's size are reviewed.

F007 Motor overload Needs a technician

What it means
The motor or drive is running above its rated current for longer than allowed.
What you can do
Reduce the load, and make sure the machine isn't jammed and the motor's ventilation isn't blocked.
When to call a technician
If it keeps happening with a normal load. The motor current value entered in the settings and the drive's size are reviewed.

F008 Heat sink overheating Needs a technician

What it means
The drive or motor temperature is outside the allowed limit.
What you can do
Clean the dust off the panel filters and the drive's heat sink, and make sure its fan turns and the room temperature is acceptable.
When to call a technician
If the code stays with good ventilation. The fan or the temperature sensor is replaced.

F009 Control module overheating Needs a technician

What it means
The drive or motor temperature is outside the allowed limit.
What you can do
Clean the dust off the panel filters and the drive's heat sink, and make sure its fan turns and the room temperature is acceptable.
When to call a technician
If the code stays with good ventilation. The fan or the temperature sensor is replaced.

F012 Overcurrent (hardware) Needs a technician

What it means
The current suddenly rose above the drive's limit: a heavy load, acceleration that is too fast, or a short in the motor or its cable.
What you can do
Make sure the mechanical load isn't jammed and turns by hand, then stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. The acceleration or deceleration time is increased, and the motor and its cable are insulation-tested.

F013 Earth fault Needs a technician

What it means
Current is leaking from one of the output phases to earth, usually from the motor cable or windings.
What you can do
Disconnect the supply and don't keep restarting.
When to call a technician
In every case. The insulation of the motor cable and windings is measured with a megger after disconnecting them from the drive.

F015 Load loss Needs a technician

What it means
The load on the motor is much lighter than expected: a broken belt, a disconnected coupling, or a pump running dry.
What you can do
Stop the motor and check its connection to the machine and that water is reaching the pump.
When to call a technician
If the load is connected and the code stays. The underload limit value in the settings is reviewed.

F021 Output phase loss Needs a technician

What it means
One of the three phases between the drive and the motor is broken or unbalanced.
What you can do
Disconnect the supply and don't run the motor on two phases.
When to call a technician
In every case. The motor cable terminals are checked at the drive and at the motor, and any contactor between them.

F029 Analogue input loss Needs a technician

What it means
The signal from the external sensor the drive uses to control the process is lost or out of range, or a pump-specific protection was triggered.
What you can do
Check the sensor and its wire, and make sure water is reaching the pump and nothing is blocking it.
When to call a technician
If the sensor and the pump are fine and the code stays.

F033 Auto-restart attempts exhausted Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.

F038 Phase U to earth Needs a technician

What it means
Current is leaking from one of the output phases to earth, usually from the motor cable or windings.
What you can do
Disconnect the supply and don't keep restarting.
When to call a technician
In every case. The insulation of the motor cable and windings is measured with a megger after disconnecting them from the drive.

F039 Phase V to earth Needs a technician

What it means
Current is leaking from one of the output phases to earth, usually from the motor cable or windings.
What you can do
Disconnect the supply and don't keep restarting.
When to call a technician
In every case. The insulation of the motor cable and windings is measured with a megger after disconnecting them from the drive.

F040 Phase W to earth Needs a technician

What it means
Current is leaking from one of the output phases to earth, usually from the motor cable or windings.
What you can do
Disconnect the supply and don't keep restarting.
When to call a technician
In every case. The insulation of the motor cable and windings is measured with a megger after disconnecting them from the drive.

F048 Parameters reset to factory defaults Needs a technician

What it means
The drive's settings returned to factory defaults.
What you can do
Re-enter the motor nameplate data and the operating settings before running it.
When to call a technician
If the settings return to factory defaults by themselves more than once.

F059 Safety circuit open Needs a technician

What it means
An external input is preventing operation: an open safety circuit, an emergency stop, or a fault signal from another device.
What you can do
Make sure the emergency stop is released and the guard doors are closed.
When to call a technician
If the safety circuit is sound and the code stays.

F064 Drive overload Needs a technician

What it means
The motor or drive is running above its rated current for longer than allowed.
What you can do
Reduce the load, and make sure the machine isn't jammed and the motor's ventilation isn't blocked.
When to call a technician
If it keeps happening with a normal load. The motor current value entered in the settings and the drive's size are reviewed.

F070 Power section fault Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.

F071 DSI network loss Needs a technician

What it means
The drive lost contact with its keypad or with the controller that sends it commands.
What you can do
Make sure the communication cable and the keypad are seated properly.
When to call a technician
If the code stays. The communication settings, address and speed are reviewed, and the cable is checked for interference.

F073 EtherNet/IP loss Needs a technician

What it means
The drive lost contact with its keypad or with the controller that sends it commands.
What you can do
Make sure the communication cable and the keypad are seated properly.
When to call a technician
If the code stays. The communication settings, address and speed are reviewed, and the cable is checked for interference.

Sources