A3tali

Home ‹ Industrial drives ‹ ABB

ABB drive error codes

8 codes, each with what it means, what you can safely try yourself, and when to call a technician.

All the codes on this page come from a single unofficial source, and we have not yet found a second one confirming them. Treat them as a first hint and check them against your appliance's manual before any repair.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
F0001OvercurrentNeeds a technician
F0002DC overvoltageNeeds a technician
F0003Device faultNeeds a technician
F0005DC undervoltageNeeds a technician
F0009Engine overheatingNeeds a technician
F0010Drive overheatingNeeds a technician
F0011Input phase lossNeeds a technician
F0021Earth faultNeeds a technician

Every code explained

Drive capacitors hold a lethal voltage for minutes after the supply is disconnected. Wait for the charge light to go out and measure the voltage before touching any terminal.

F0001 Overcurrent Needs a technician

What it means
The current suddenly rose above the drive's limit: a heavy load, acceleration that is too fast, or a short in the motor or its cable.
What the source says
Output current exceeded the protection limit
What you can do
Make sure the mechanical load isn't jammed and turns by hand, then stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. The acceleration or deceleration time is increased, and the motor and its cable are insulation-tested.
Note
ACS550 model

F0002 DC overvoltage Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What the source says
The internal DC bus voltage exceeded the trip limit
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.

F0003 Device fault Needs a technician

What it means
An internal drive fault: memory, processor or one of the circuits.
What the source says
Internal hardware fault
What you can do
Stop the motor, disconnect the drive's supply and wait until its display and charge light go out, then restart.
When to call a technician
If the code comes back. It may need a factory reset or a board replacement.

F0005 DC undervoltage Needs a technician

What it means
The supply reaching the drive is deficient: low voltage, a missing phase, or a momentary dip.
What the source says
The internal DC bus voltage fell below the minimum
What you can do
Make sure the breaker and fuses ahead of the drive are sound and all three phases are present.
When to call a technician
If the supply is sound and the code stays. The charging circuit and capacitors inside the drive are checked.

F0009 Engine overheating Needs a technician

What it means
The drive or motor temperature is outside the allowed limit.
What the source says
The motor exceeded its thermal limit
What you can do
Clean the dust off the panel filters and the drive's heat sink, and make sure its fan turns and the room temperature is acceptable.
When to call a technician
If the code stays with good ventilation. The fan or the temperature sensor is replaced.

F0010 Drive overheating Needs a technician

What it means
The drive or motor temperature is outside the allowed limit.
What the source says
Heat sink temperature exceeded the limit
What you can do
Clean the dust off the panel filters and the drive's heat sink, and make sure its fan turns and the room temperature is acceptable.
When to call a technician
If the code stays with good ventilation. The fan or the temperature sensor is replaced.

F0011 Input phase loss Needs a technician

What it means
The supply reaching the drive is deficient: low voltage, a missing phase, or a momentary dip.
What you can do
Make sure the breaker and fuses ahead of the drive are sound and all three phases are present.
When to call a technician
If the supply is sound and the code stays. The charging circuit and capacitors inside the drive are checked.

F0021 Earth fault Needs a technician

What it means
Current is leaking from one of the output phases to earth, usually from the motor cable or windings.
What the source says
Earth fault in the motor cable
What you can do
Disconnect the supply and don't keep restarting.
When to call a technician
In every case. The insulation of the motor cable and windings is measured with a megger after disconnecting them from the drive.