APC UPS error codes

12 codes, each with what it means, what you can safely try yourself, and when to call a technician. Codes F01 to F09 appear on the display of Back-UPS Pro units, and the beeps are shared by most models.

1 of the 12 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
F01Overload while running on batteryTry it yourself first
F02Output short circuit while running on batteryTry it yourself first
F03Overload on the protection circuitNeeds a technician
F04Short circuit in the regulation circuitNeeds a technician
F05Internal charger faultNeeds a technician
F06Relay stuckNeeds a technician
F07OverheatingTry it yourself first
F08Fan faultNeeds a technician
F09Internal faultNeeds a technician
4 beeps every 30 secondsThe unit is running on batteryNot a fault
Continuous beepingThe battery is about to run outTry it yourself first
A one-minute beep every 5 hoursThe battery failed its self-testTry it yourself first

Every code explained

Don't open the unit: the internal battery holds energy even when unplugged.

F01 Overload while running on battery Try it yourself first

What it means
The connected devices are drawing more than the unit's capacity while it runs on battery.
What you can do
Switch off the unit, unplug unnecessary devices from the battery outlets, then switch it on.
When to call a technician
If the code appears with light loads.

F02 Output short circuit while running on battery Try it yourself first

What it means
One of the connected devices has a short circuit, or the battery isn't connected internally.
What you can do
Unplug all devices, switch the unit on, then reconnect them one at a time to find which is the cause. If the code appears with no devices, make sure the internal battery connector is seated.
When to call a technician
If the code stays with no device connected.

F03 Overload on the protection circuit Needs a technician

What it means
An internal circuit in the unit took more than it can handle.
What you can do
Switch the unit off and on once.
When to call a technician
If the code comes back. The company recommends contacting support.

F04 Short circuit in the regulation circuit Needs a technician

What it means
An internal fault. On some models at start-up it means the battery isn't connected.
What you can do
Make sure the battery is connected properly if the unit is new.
When to call a technician
If the code stays.

F05 Internal charger fault Needs a technician

What it means
The unit can't charge the battery.
What you can do
Check the wall power. Don't buy a new battery before checking, as the fault may be in the charger, not the battery.
When to call a technician
Straight away.

F06 Relay stuck Needs a technician

What it means
An internal relay has stuck and won't move.
What you can do
Stop restarting it repeatedly.
When to call a technician
Straight away.

F07 Overheating Try it yourself first

What it means
The unit got hotter than it should.
What you can do
Move the unit away from the wall and heat, and make sure the vents are open.
When to call a technician
If it keeps happening in a well-ventilated place.

F08 Fan fault Needs a technician

What it means
The internal cooling fan isn't working.
What you can do
Clean the dust from the vents on the outside.
When to call a technician
Straight away.

F09 Internal fault Needs a technician

What it means
A fault in the internal control logic.
What you can do
Try one full restart.
When to call a technician
If the code comes back.

4 beeps every 30 seconds The unit is running on battery Not a fault

What it means
The power went out and the unit is powering your devices from the battery. Not a fault.
What you can do
Save your work. If the outage lasts, shut down the computer properly.
When to call a technician
Doesn't need a technician.

Continuous beeping The battery is about to run out Try it yourself first

What it means
The battery is very low and the unit will switch off soon.
What you can do
Close your programs and shut down the computer immediately.
When to call a technician
Doesn't need a technician unless the battery runs out abnormally fast.

Codes from a single source

We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.

A one-minute beep every 5 hours The battery failed its self-test Try it yourself first

What it means
The battery is weak and needs replacing.
What you can do
Replace the battery with the type printed on the unit's label.
When to call a technician
Usually doesn't need a technician.