Victron inverter error codes

25 codes, each with what it means, what you can safely try yourself, and when to call a technician. These are VE.Bus codes for MultiPlus and Quattro systems, and most concern systems made up of more than one unit.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
1The device switched off because of a fault on another phaseTry it yourself first
2Old and new MK2 protocol mixed in the systemNeeds a technician
3Not all expected devices were foundTry it yourself first
4No other device was foundTry it yourself first
5Overvoltage on the AC outputNeeds a technician
6DDC software errorNeeds a technician
7An external device is connected and needs a setup assistantNeeds a technician
8Earth relay test failedNeeds a technician
10System time synchronisation problemTry it yourself first
11Relay test faultNeeds a technician
12Setting mismatch with the second processorNeeds a technician
14The device can't transmit dataNeeds a technician
15VE.Bus combination errorNeeds a technician
16VE.Bus dongle missingNeeds a technician
17Master phase missingTry it yourself first
18AC overvoltage on the slave's output while it is offNeeds a technician
19The slave unit has no AC inputNeeds a technician
20Setting mismatchNeeds a technician
22The device isn't suitable as a slave unitNeeds a technician
24Transfer system protection activatedNeeds a technician
25Incompatible VE.Bus settingNeeds a technician
26Internal errorTry it yourself first
30False error, corrupted VE.Bus messageTry it yourself first
31False error, corrupted VE.Bus messageTry it yourself first
128Connection prevented because the relay test failedNeeds a technician

Every code explained

The panels generate dangerous voltage whenever light falls on them, even with the inverter switched off. Everything under “What you can do” is done without touching the panel cables.

1 The device switched off because of a fault on another phase Try it yourself first

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What the source says
Check the lights on the failed phase: overload, low battery or heat
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.
Note
Codes for MultiPlus, Quattro and EasySolar

2 Old and new MK2 protocol mixed in the system Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
All firmware is updated
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

3 Not all expected devices were found Try it yourself first

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What the source says
Check the cables and the setting
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

4 No other device was found Try it yourself first

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What the source says
Check the communication cables
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

5 Overvoltage on the AC output Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Check the AC connection on the slave units
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

6 DDC software error Needs a technician

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What the source says
Update the firmware and redo the setup
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

7 An external device is connected and needs a setup assistant Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What the source says
Set up the appropriate Assistant
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

8 Earth relay test failed Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Check the connection and the neutral
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

10 System time synchronisation problem Try it yourself first

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Restart the system and check the DC fuses
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

11 Relay test fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
An installation error or relay fault. Check the neutral
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

12 Setting mismatch with the second processor Needs a technician

What it means
A setting in the inverter doesn't suit the system connected to it.
What the source says
Resend the full configuration
What you can do
Don't change settings by trial and error.
When to call a technician
In every case. The installer reviews the intended setting.

14 The device can't transmit data Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What the source says
Check the communication cables for a short
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

15 VE.Bus combination error Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What the source says
Update all firmware
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

16 VE.Bus dongle missing Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What the source says
Update the firmware
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

17 Master phase missing Try it yourself first

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What the source says
Check the network cables
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

18 AC overvoltage on the slave's output while it is off Needs a technician

What it means
A unit in a multi-unit system isn't in the state the system expects.
What the source says
Make sure the AC wires aren't reversed
What you can do
Make sure all units are powered and running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

19 The slave unit has no AC input Needs a technician

What it means
A unit in a multi-unit system isn't in the state the system expects.
What the source says
Connect the AC input to every unit
What you can do
Make sure all units are powered and running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

20 Setting mismatch Needs a technician

What it means
A setting in the inverter doesn't suit the system connected to it.
What you can do
Don't change settings by trial and error.
When to call a technician
In every case. The installer reviews the intended setting.

22 The device isn't suitable as a slave unit Needs a technician

What it means
A unit in a multi-unit system isn't in the state the system expects.
What the source says
An old model that gets replaced
What you can do
Make sure all units are powered and running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

24 Transfer system protection activated Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Reduce the load, or a faulty relay
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

25 Incompatible VE.Bus setting Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What the source says
Update the firmware
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

26 Internal error Try it yourself first

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Restart the system
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

30 False error, corrupted VE.Bus message Try it yourself first

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What the source says
Check the RJ45 cables
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

31 False error, corrupted VE.Bus message Try it yourself first

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What the source says
Check the RJ45 cables
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

128 Connection prevented because the relay test failed Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

Sources