SolaX inverter error codes

57 codes, each with what it means, what you can safely try yourself, and when to call a technician.

48 of the 57 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
SPI FaultSPI communication faultNeeds a technician
SCI FaultSCI communication faultTry it yourself first
CAN1 FaultCAN communication faultNeeds a technician
PV Config FaultPanel connection setting faultNeeds a technician
Inv EEPROM FaultInverter memory faultTry it yourself first
Relay FaultRelay faultTry it yourself first
Sample FaultMeasurement circuit faultTry it yourself first
RCD FaultLeakage current device faultTry it yourself first
Fan1 FaultFan 1 faultNeeds a technician
Fan2 FaultFan 2 faultNeeds a technician
AC HCT FaultAC current sensor faultNeeds a technician
OverLoad FaultOverload in EPS backup modeTry it yourself first
EPS OCP FaultOvercurrent in EPS backup modeTry it yourself first
DCI Device FaultDCI device faultNeeds a technician
EPS Relay FaultEPS relay faultNeeds a technician
TZ Protect FaultOvercurrent faultTry it yourself first
Grid Lost FaultGrid connection lostTry it yourself first
Grid Volt FaultGrid voltage out of limitsTry it yourself first
Grid Freq FaultGrid frequency out of limitsTry it yourself first
PLL Lost FaultPoor grid qualityTry it yourself first
Bus Volt FaultAbnormal internal bus voltageTry it yourself first
AC5M Volt FaultGrid voltage high for five minutesTry it yourself first
AC10M Volt FaultGrid voltage high for ten minutesTry it yourself first
Inv OCP FaultInverter overcurrent protectionNeeds a technician
PV Volt FaultPanel voltage faultNeeds a technician
Isolation FaultInsulation faultNeeds a technician
Temp Over FaultTemperature exceeds the limitTry it yourself first
Fan1 Speed FaultAbnormal fan 1 speedTry it yourself first
Fan2 Speed FaultAbnormal fan 2 speedTry it yourself first
C1 Can FaultCAN communication fault with the batteryTry it yourself first
C1 Temp HighBattery charger overheatingTry it yourself first
C1 FAN FaultBattery charger fan faultNeeds a technician
C1 TZ FaultBattery charger protection faultNeeds a technician
C1 EEPROM FaultBattery charger memory faultNeeds a technician
C1 HCT1 FaultCharger current measurement faultNeeds a technician
C1 HCT2 FaultCharger current measurement faultNeeds a technician
C1 Bus OVPBattery charger bus overvoltageNeeds a technician
C1 Temp LowBattery charger temperature lowNeeds a technician
C1 Boost OVPCharger boost overvoltageNeeds a technician
C1 Bat OVPBattery overvoltageNeeds a technician
C1 Charger OCPBattery charger overcurrentNeeds a technician
C1 Boost OCPCharger boost overcurrentNeeds a technician
CT FaultWeak CT or meter connectionTry it yourself first
RC FaultDCI protection faultNeeds a technician
DCI OCP FaultDCI current protection faultNeeds a technician
Other device FaultFault in another deviceNeeds a technician
SW OCP FaultSoftware overcurrent detectedNeeds a technician
DM9000 FaultGrid DSP faultNeeds a technician
RTC FaultRTC clock faultNeeds a technician
Mgr EEPROM FaultManagement unit memory faultNeeds a technician
Mgr CAN FaultManagement unit CAN faultNeeds a technician
C1 SPI FaultCharger communication faultNeeds a technician
C1 TZCharger overcurrent detectedNeeds a technician
C1 sample FaultCharger measurement faultNeeds a technician
Bat Volt FaultBattery voltage outside the normal rangeNeeds a technician
Bat Con Dir FaultThe battery connection direction may be wrongNeeds a technician
EPS Overload FaultThe loads exceed the EPS backup capacityTry it yourself first

Every code explained

The panels generate dangerous voltage whenever light falls on them, even with the inverter switched off. Everything under “What you can do” is done without touching the panel cables.

TZ Protect Fault Overcurrent fault Try it yourself first

What it means
The current through the inverter is higher than it can handle.
What the source says
Wait, then restart
What you can do
Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
When to call a technician
If it appears without large loads. There may be a short in the wiring or a fault in the inverter.

Grid Lost Fault Grid connection lost Try it yourself first

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What the source says
Wait for the grid to return
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.

Grid Volt Fault Grid voltage out of limits Try it yourself first

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What the source says
Wait for the grid to return to normal
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.

Grid Freq Fault Grid frequency out of limits Try it yourself first

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What the source says
Wait for the grid to return to normal
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.

PV Volt Fault Panel voltage fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

Isolation Fault Insulation fault Needs a technician

What it means
The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
What you can do
Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
When to call a technician
If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.

Bat Volt Fault Battery voltage outside the normal range Needs a technician

What it means
A problem with the battery or its communication with the inverter.
What the source says
Check the battery's status
What you can do
Make sure the battery breaker is on and the communication cable between it and the inverter is seated properly.
When to call a technician
If the code stays. The installer reviews the battery settings and voltage.
Note
Its number is IE 07

Bat Con Dir Fault The battery connection direction may be wrong Needs a technician

What it means
A problem with the battery or its communication with the inverter.
What the source says
Don't change the cables yourself; contact the installer
What you can do
Make sure the battery breaker is on and the communication cable between it and the inverter is seated properly.
When to call a technician
If the code stays. The installer reviews the battery settings and voltage.
Note
Its number is IE 15

EPS Overload Fault The loads exceed the EPS backup capacity Try it yourself first

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Reduce high loads
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
Note
Its number is IE 16

Codes from a single source

We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.

SPI Fault SPI communication fault Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.
Note
Text messages, not codes

SCI Fault SCI communication fault Try it yourself first

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What the source says
Switch the system off and restart it
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

CAN1 Fault CAN communication fault Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

PV Config Fault Panel connection setting fault Needs a technician

What it means
A setting in the inverter doesn't suit the system connected to it.
What the source says
Reset the panel connection setting
What you can do
Don't change settings by trial and error.
When to call a technician
In every case. The installer reviews the intended setting.

Inv EEPROM Fault Inverter memory fault Try it yourself first

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What the source says
Switch the system off and restart it
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

Relay Fault Relay fault Try it yourself first

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Switch the system off and restart it
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

Sample Fault Measurement circuit fault Try it yourself first

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Switch the system off and restart it
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

RCD Fault Leakage current device fault Try it yourself first

What it means
The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
What the source says
Switch the system off and restart it
What you can do
Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
When to call a technician
If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.

Fan1 Fault Fan 1 fault Needs a technician

What it means
The cooling fan isn't turning properly.
What you can do
Switch off the inverter, see whether anything is blocking the fan opening, and clean the dust from outside.
When to call a technician
If the code stays. The fan is replaced.

Fan2 Fault Fan 2 fault Needs a technician

What it means
The cooling fan isn't turning properly.
What you can do
Switch off the inverter, see whether anything is blocking the fan opening, and clean the dust from outside.
When to call a technician
If the code stays. The fan is replaced.

AC HCT Fault AC current sensor fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

OverLoad Fault Overload in EPS backup mode Try it yourself first

What it means
The current through the inverter is higher than it can handle.
What the source says
Switch off high-power appliances
What you can do
Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
When to call a technician
If it appears without large loads. There may be a short in the wiring or a fault in the inverter.

EPS OCP Fault Overcurrent in EPS backup mode Try it yourself first

What it means
The current through the inverter is higher than it can handle.
What the source says
Reduce the load
What you can do
Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
When to call a technician
If it appears without large loads. There may be a short in the wiring or a fault in the inverter.

DCI Device Fault DCI device fault Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

EPS Relay Fault EPS relay fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

PLL Lost Fault Poor grid quality Try it yourself first

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.

Bus Volt Fault Abnormal internal bus voltage Try it yourself first

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Switch the system off and restart it
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

AC5M Volt Fault Grid voltage high for five minutes Try it yourself first

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.

AC10M Volt Fault Grid voltage high for ten minutes Try it yourself first

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.

Inv OCP Fault Inverter overcurrent protection Needs a technician

What it means
The current through the inverter is higher than it can handle.
What you can do
Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
When to call a technician
If it appears without large loads. There may be a short in the wiring or a fault in the inverter.

Temp Over Fault Temperature exceeds the limit Try it yourself first

What it means
The inverter got hotter than allowed, so it reduced its output or stopped.
What the source says
Check the fan and reduce the heat
What you can do
Make sure there is clear space around it for ventilation and it isn't in direct sun, and clean the dust from the vents.
When to call a technician
If it keeps happening with good ventilation. The internal fan or the temperature sensor may be faulty.

Fan1 Speed Fault Abnormal fan 1 speed Try it yourself first

What it means
The cooling fan isn't turning properly.
What the source says
Clean it of dust
What you can do
Switch off the inverter, see whether anything is blocking the fan opening, and clean the dust from outside.
When to call a technician
If the code stays. The fan is replaced.

Fan2 Speed Fault Abnormal fan 2 speed Try it yourself first

What it means
The cooling fan isn't turning properly.
What the source says
Clean it of dust
What you can do
Switch off the inverter, see whether anything is blocking the fan opening, and clean the dust from outside.
When to call a technician
If the code stays. The fan is replaced.

C1 Can Fault CAN communication fault with the battery Try it yourself first

What it means
A problem with the battery or its communication with the inverter.
What the source says
Reconnect the charger cable
What you can do
Make sure the battery breaker is on and the communication cable between it and the inverter is seated properly.
When to call a technician
If the code stays. The installer reviews the battery settings and voltage.

C1 Temp High Battery charger overheating Try it yourself first

What it means
A problem with the battery or its communication with the inverter.
What you can do
Make sure the battery breaker is on and the communication cable between it and the inverter is seated properly.
When to call a technician
If the code stays. The installer reviews the battery settings and voltage.

C1 FAN Fault Battery charger fan fault Needs a technician

What it means
A problem with the battery or its communication with the inverter.
What you can do
Make sure the battery breaker is on and the communication cable between it and the inverter is seated properly.
When to call a technician
If the code stays. The installer reviews the battery settings and voltage.

C1 TZ Fault Battery charger protection fault Needs a technician

What it means
A problem with the battery or its communication with the inverter.
What you can do
Make sure the battery breaker is on and the communication cable between it and the inverter is seated properly.
When to call a technician
If the code stays. The installer reviews the battery settings and voltage.

C1 EEPROM Fault Battery charger memory fault Needs a technician

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

C1 HCT1 Fault Charger current measurement fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

C1 HCT2 Fault Charger current measurement fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

C1 Bus OVP Battery charger bus overvoltage Needs a technician

What it means
A problem with the battery or its communication with the inverter.
What you can do
Make sure the battery breaker is on and the communication cable between it and the inverter is seated properly.
When to call a technician
If the code stays. The installer reviews the battery settings and voltage.

C1 Temp Low Battery charger temperature low Needs a technician

What it means
A problem with the battery or its communication with the inverter.
What you can do
Make sure the battery breaker is on and the communication cable between it and the inverter is seated properly.
When to call a technician
If the code stays. The installer reviews the battery settings and voltage.

C1 Boost OVP Charger boost overvoltage Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

C1 Bat OVP Battery overvoltage Needs a technician

What it means
A problem with the battery or its communication with the inverter.
What you can do
Make sure the battery breaker is on and the communication cable between it and the inverter is seated properly.
When to call a technician
If the code stays. The installer reviews the battery settings and voltage.

C1 Charger OCP Battery charger overcurrent Needs a technician

What it means
A problem with the battery or its communication with the inverter.
What you can do
Make sure the battery breaker is on and the communication cable between it and the inverter is seated properly.
When to call a technician
If the code stays. The installer reviews the battery settings and voltage.

C1 Boost OCP Charger boost overcurrent Needs a technician

What it means
The current through the inverter is higher than it can handle.
What you can do
Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
When to call a technician
If it appears without large loads. There may be a short in the wiring or a fault in the inverter.

CT Fault Weak CT or meter connection Try it yourself first

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What the source says
Check the CT or meter connection
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

RC Fault DCI protection fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

DCI OCP Fault DCI current protection fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

Other device Fault Fault in another device Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

SW OCP Fault Software overcurrent detected Needs a technician

What it means
The current through the inverter is higher than it can handle.
What you can do
Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
When to call a technician
If it appears without large loads. There may be a short in the wiring or a fault in the inverter.

DM9000 Fault Grid DSP fault Needs a technician

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.

RTC Fault RTC clock fault Needs a technician

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

Mgr EEPROM Fault Management unit memory fault Needs a technician

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

Mgr CAN Fault Management unit CAN fault Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

C1 SPI Fault Charger communication fault Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

C1 TZ Charger overcurrent detected Needs a technician

What it means
The current through the inverter is higher than it can handle.
What you can do
Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
When to call a technician
If it appears without large loads. There may be a short in the wiring or a fault in the inverter.

C1 sample Fault Charger measurement fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.