Huawei inverter error codes
30 codes, each with what it means, what you can safely try yourself, and when to call a technician. Alarm codes for the SUN2000 series, which appear in the FusionSolar app.
13 of the 30 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.
A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.
Quick table
| Code | Meaning | Who handles it |
|---|
103 | DC input voltage high | Needs a technician |
106 | String 1 fault | Needs a technician |
120 | String 1 reversed polarity | Needs a technician |
200 | DC circuit fault | Needs a technician |
202 | Conversion circuit fault | Needs a technician |
301 | Abnormal grid voltage | Try it yourself first |
305 | Abnormal grid frequency | Try it yourself first |
313 | Low insulation resistance | Needs a technician |
318 | Abnormal leakage current | Needs a technician |
321 | Overheating inside the drive | Try it yourself first |
322 | SPI communication fault | Needs a technician |
326 | Earthing fault | Needs a technician |
400 | System fault | Needs a technician |
410 | Auxiliary supply fault | Needs a technician |
504 | Software version mismatch | Try it yourself first |
505 | Upgrade failed | Try it yourself first |
61440 | Flash memory fault | Needs a technician |
107 | String 2 fault | Needs a technician |
108 | String 3 fault | Needs a technician |
109 | String 4 fault | Needs a technician |
110 | String 5 fault | Needs a technician |
111 | String 6 fault | Needs a technician |
121 | String 2 reversed polarity | Needs a technician |
122 | String 3 reversed polarity | Needs a technician |
123 | String 4 reversed polarity | Needs a technician |
124 | String 5 reversed polarity | Needs a technician |
125 | String 6 reversed polarity | Needs a technician |
2032 | Grid outage | Try it yourself first |
2033 | Grid voltage low | Try it yourself first |
2034 | Grid voltage high | Try it yourself first |
Every code explained
The panels generate dangerous voltage whenever light falls on them, even with the inverter switched off. Everything under “What you can do” is done without touching the panel cables.
103 DC input voltage high Needs a technician
- What it means
- A problem connecting the panel strings: a voltage higher than the inverter can handle, reversed polarity, or a short in the string.
- What the source says
- Too many panels connected in series
- What you can do
- Nothing on your side. Don't disconnect the panel connections while the sun is shining, as arcing is dangerous.
- When to call a technician
- In every case. The installer reviews the number of panels in each string and their connection.
- Note
- Codes 107 to 111 are for strings 2 to 6, and 121 to 125 likewise. The page is for SUN2000 30-40KTL models
106 String 1 fault Needs a technician
- What it means
- A problem connecting the panel strings: a voltage higher than the inverter can handle, reversed polarity, or a short in the string.
- What the source says
- The string is shaded, degraded or damaged
- What you can do
- Nothing on your side. Don't disconnect the panel connections while the sun is shining, as arcing is dangerous.
- When to call a technician
- In every case. The installer reviews the number of panels in each string and their connection.
120 String 1 reversed polarity Needs a technician
- What it means
- A problem connecting the panel strings: a voltage higher than the inverter can handle, reversed polarity, or a short in the string.
- What the source says
- Reversed polarity or too few panels in the string
- What you can do
- Nothing on your side. Don't disconnect the panel connections while the sun is shining, as arcing is dangerous.
- When to call a technician
- In every case. The installer reviews the number of panels in each string and their connection.
200 DC circuit fault Needs a technician
- What it means
- An internal fault the inverter detected in one of its circuits.
- What the source says
- Input disconnected, unstable voltage, or an internal fault
- What you can do
- Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
202 Conversion circuit fault Needs a technician
- What it means
- An internal fault the inverter detected in one of its circuits.
- What the source says
- Grid voltage dip or an output short circuit
- What you can do
- Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
301 Abnormal grid voltage Try it yourself first
- What it means
- The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
- What the source says
- Voltage out of limits or unbalanced phases
- What you can do
- Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
- When to call a technician
- If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.
305 Abnormal grid frequency Try it yourself first
- What it means
- The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
- What the source says
- Frequency out of limits
- What you can do
- Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
- When to call a technician
- If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.
313 Low insulation resistance Needs a technician
- What it means
- The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
- What the source says
- Short between the panel string and the earth wire
- What you can do
- Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
- When to call a technician
- If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.
318 Abnormal leakage current Needs a technician
- What it means
- The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
- What the source says
- Low insulation resistance
- What you can do
- Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
- When to call a technician
- If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.
321 Overheating inside the drive Try it yourself first
- What it means
- The inverter got hotter than allowed, so it reduced its output or stopped.
- What the source says
- Poor ventilation, high ambient temperature, or a fan fault
- What you can do
- Make sure there is clear space around it for ventilation and it isn't in direct sun, and clean the dust from the vents.
- When to call a technician
- If it keeps happening with good ventilation. The internal fan or the temperature sensor may be faulty.
322 SPI communication fault Needs a technician
- What it means
- The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
- What the source says
- An internal circuit fault that doesn't self-repair
- What you can do
- Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code stays. The installer reviews the link settings between the units.
326 Earthing fault Needs a technician
- What it means
- The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
- What the source says
- The neutral or earth wire isn't connected properly
- What you can do
- Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
- When to call a technician
- If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.
400 System fault Needs a technician
- What it means
- An internal fault the inverter detected in one of its circuits.
- What the source says
- An internal circuit fault that doesn't self-repair
- What you can do
- Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
410 Auxiliary supply fault Needs a technician
- What it means
- An internal fault the inverter detected in one of its circuits.
- What the source says
- Abnormal measurement board voltage
- What you can do
- Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
504 Software version mismatch Try it yourself first
- What it means
- A fault in the inverter's software or memory or in its update process, not in the power itself.
- What the source says
- Wrong software during the upgrade
- What you can do
- Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code stays. It needs a firmware update or a reset by the installer.
505 Upgrade failed Try it yourself first
- What it means
- A fault in the inverter's software or memory or in its update process, not in the power itself.
- What you can do
- Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code stays. It needs a firmware update or a reset by the installer.
61440 Flash memory fault Needs a technician
- What it means
- A fault in the inverter's software or memory or in its update process, not in the power itself.
- What the source says
- Insufficient memory or bad sectors in it
- What you can do
- Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code stays. It needs a firmware update or a reset by the installer.
Codes from a single source
We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.
107 String 2 fault Needs a technician
- What it means
- String 2's current is clearly lower than the other strings, usually because of shade, dirt or damaged panels.
- What you can do
- Clean the panels, and make sure there is no permanent shade on them from a tree or building.
- When to call a technician
- If the alarm stays with clean panels. The technician checks the panels and connections.
108 String 3 fault Needs a technician
- What it means
- String 3's current is clearly lower than the other strings, usually because of shade, dirt or damaged panels.
- What you can do
- Clean the panels, and make sure there is no permanent shade on them from a tree or building.
- When to call a technician
- If the alarm stays with clean panels. The technician checks the panels and connections.
109 String 4 fault Needs a technician
- What it means
- String 4's current is clearly lower than the other strings, usually because of shade, dirt or damaged panels.
- What you can do
- Clean the panels, and make sure there is no permanent shade on them from a tree or building.
- When to call a technician
- If the alarm stays with clean panels. The technician checks the panels and connections.
110 String 5 fault Needs a technician
- What it means
- String 5's current is clearly lower than the other strings, usually because of shade, dirt or damaged panels.
- What you can do
- Clean the panels, and make sure there is no permanent shade on them from a tree or building.
- When to call a technician
- If the alarm stays with clean panels. The technician checks the panels and connections.
111 String 6 fault Needs a technician
- What it means
- String 6's current is clearly lower than the other strings, usually because of shade, dirt or damaged panels.
- What you can do
- Clean the panels, and make sure there is no permanent shade on them from a tree or building.
- When to call a technician
- If the alarm stays with clean panels. The technician checks the panels and connections.
121 String 2 reversed polarity Needs a technician
- What it means
- String 2 is connected in reverse, or has too few panels.
- What you can do
- Don't touch the panel cables.
- When to call a technician
- Straight away. The technician corrects the connection after the string voltage drops.
122 String 3 reversed polarity Needs a technician
- What it means
- String 3 is connected in reverse, or has too few panels.
- What you can do
- Don't touch the panel cables.
- When to call a technician
- Straight away. The technician corrects the connection after the string voltage drops.
123 String 4 reversed polarity Needs a technician
- What it means
- String 4 is connected in reverse, or has too few panels.
- What you can do
- Don't touch the panel cables.
- When to call a technician
- Straight away. The technician corrects the connection after the string voltage drops.
124 String 5 reversed polarity Needs a technician
- What it means
- String 5 is connected in reverse, or has too few panels.
- What you can do
- Don't touch the panel cables.
- When to call a technician
- Straight away. The technician corrects the connection after the string voltage drops.
125 String 6 reversed polarity Needs a technician
- What it means
- String 6 is connected in reverse, or has too few panels.
- What you can do
- Don't touch the panel cables.
- When to call a technician
- Straight away. The technician corrects the connection after the string voltage drops.
2032 Grid outage Try it yourself first
- What it means
- The inverter can't see grid power, or the AC breaker is off.
- What you can do
- Make sure grid power is present and the inverter's AC breaker is on.
- When to call a technician
- If power is present, the breaker is on and the alarm stays.
2033 Grid voltage low Try it yourself first
- What it means
- The public grid voltage is below the allowed limit.
- What you can do
- If it is brief, the inverter recovers by itself. If it happens often, monitor the voltage in the house.
- When to call a technician
- If it continues. Don't change the protection limits without the power company's approval.
2034 Grid voltage high Try it yourself first
- What it means
- The public grid voltage is above the allowed limit.
- What you can do
- If it is brief, the inverter recovers by itself. If it happens often, monitor the voltage in the house.
- When to call a technician
- If it continues. Don't change the protection limits without the power company's approval.