Growatt inverter error codes

34 codes, each with what it means, what you can safely try yourself, and when to call a technician. Newer series show a number (Error 3xx and 4xx) with text; older ones show the text alone.

10 of the 34 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
No AC ConnectionNo grid connected, or the grid is downTry it yourself first
AC V OutrangeGrid voltage outside the allowed limitTry it yourself first
AC F OutrangeGrid frequency outside the allowed limitTry it yourself first
Over TemperatureTemperature outside the limitTry it yourself first
PV Isolation LowPanel insulation problemNeeds a technician
Output High DCIOutput DC offset highTry it yourself first
Residual I HighLeakage current highTry it yourself first
PV Voltage HighPanel input voltage exceeds the maximumTry it yourself first
Auto Test FailedAuto-test failedTry it yourself first
Error 1002.5 V reference voltage faultNeeds a technician
Error 101Communication faultNeeds a technician
Error 102Master and slave processor data mismatchTry it yourself first
Error 116EEPROM faultNeeds a technician
Error 117Relay faultNeeds a technician
Error 118Model initialisation faultNeeds a technician
Error 119GFCI device damagedNeeds a technician
Error 120HCT current sensor faultNeeds a technician
Error 121The master processor isn't receiving from the slaveTry it yourself first
Error 122Internal bus voltage faultNeeds a technician
PE abnormalVoltage between neutral and earth above 30 VNeeds a technician
Error 404Internal bus voltage measurement faultTry it yourself first
Error 405Relay faultTry it yourself first
Error 409Internal bus overvoltageTry it yourself first
Error 411Communication fault between the DSP and M3 processorsNeeds a technician
Error 414EEPROM faultTry it yourself first
Error 417Processor readings mismatchTry it yourself first
Error 420GFCI device faultTry it yourself first
Warning 203Short circuit in the PV1 or PV2 circuitNeeds a technician
Warning 204Dry contact function faultNeeds a technician
Warning 205Boost circuit damaged in PV1 or PV2Needs a technician
Warning 207Overcurrent on the USB portTry it yourself first
Warning 401Communication fault with the meterTry it yourself first
Warning 404EEPROM faultTry it yourself first
Warning 405Firmware versions don't matchNeeds a technician

Every code explained

The panels generate dangerous voltage whenever light falls on them, even with the inverter switched off. Everything under “What you can do” is done without touching the panel cables.

No AC Connection No grid connected, or the grid is down Try it yourself first

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What the source says
Check the AC connection
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.
Note
Its number is Error 302 on the MIN TL-XH series

AC V Outrange Grid voltage outside the allowed limit Try it yourself first

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.
Note
Its number is Error 300 on the MIN TL-XH series

AC F Outrange Grid frequency outside the allowed limit Try it yourself first

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.
Note
Its number is Error 304 on the MIN TL-XH series

Over Temperature Temperature outside the limit Try it yourself first

What it means
The inverter got hotter than allowed, so it reduced its output or stopped.
What you can do
Make sure there is clear space around it for ventilation and it isn't in direct sun, and clean the dust from the vents.
When to call a technician
If it keeps happening with good ventilation. The internal fan or the temperature sensor may be faulty.
Note
Its number is Error 408 on the MIN TL-XH series

PV Isolation Low Panel insulation problem Needs a technician

What it means
The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
What the source says
Check the inverter's earthing and the DC breaker
What you can do
Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
When to call a technician
If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.
Note
Its number is Error 203 on the MIN TL-XH series

Output High DCI Output DC offset high Try it yourself first

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Restart the inverter
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
Note
Its number is Error 402 on the MIN TL-XH series

Residual I High Leakage current high Try it yourself first

What it means
The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
What the source says
Restart the inverter
What you can do
Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
When to call a technician
If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.
Note
Its number is Error 201 on the MIN TL-XH series

PV Voltage High Panel input voltage exceeds the maximum Try it yourself first

What it means
A problem connecting the panel strings: a voltage higher than the inverter can handle, reversed polarity, or a short in the string.
What the source says
Switch off the DC switch immediately
What you can do
Nothing on your side. Don't disconnect the panel connections while the sun is shining, as arcing is dangerous.
When to call a technician
In every case. The installer reviews the number of panels in each string and their connection.
Note
Its number is Error 202 on the MIN TL-XH series

Auto Test Failed Auto-test failed Try it yourself first

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Restart the inverter
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
Note
Its number is Error 407 on the MIN TL-XH series

PE abnormal Voltage between neutral and earth above 30 V Needs a technician

What it means
The AC side connection isn't sound: neutral or earth disconnected, or wires reversed.
What the source says
Check the AC connections and earthing, then restart
What you can do
Nothing on your side except making sure the AC breaker is on.
When to call a technician
In every case. The neutral and earth connections are checked at the inverter and the distribution board.
Note
Its number is Error 303

Error 404 Internal bus voltage measurement fault Try it yourself first

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Restart the inverter, and if it persists, contact the company
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
Note
MIN TL-XH series

Error 405 Relay fault Try it yourself first

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Restart the inverter, and if it persists, contact the company
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
Note
MIN TL-XH series. On older series its number is Error 117

Error 409 Internal bus overvoltage Try it yourself first

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Restart the inverter, and if it persists, contact the company
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
Note
MIN TL-XH series

Error 411 Communication fault between the DSP and M3 processors Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What the source says
Restart and update the firmware
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.
Note
MIN TL-XH series

Error 414 EEPROM fault Try it yourself first

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What the source says
Restart the inverter, and if it persists, contact the company
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.
Note
MIN TL-XH series

Error 417 Processor readings mismatch Try it yourself first

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Restart the inverter, and if it persists, contact the company
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
Note
MIN TL-XH series

Error 420 GFCI device fault Try it yourself first

What it means
The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
What the source says
Restart the inverter, and if it persists, contact the company
What you can do
Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
When to call a technician
If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.
Note
MIN TL-XH series

Warning 203 Short circuit in the PV1 or PV2 circuit Needs a technician

What it means
A problem connecting the panel strings: a voltage higher than the inverter can handle, reversed polarity, or a short in the string.
What the source says
Check the panel polarity and restart
What you can do
Nothing on your side. Don't disconnect the panel connections while the sun is shining, as arcing is dangerous.
When to call a technician
In every case. The installer reviews the number of panels in each string and their connection.

Warning 204 Dry contact function fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Check its connection after switching off
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

Warning 205 Boost circuit damaged in PV1 or PV2 Needs a technician

What it means
A problem connecting the panel strings: a voltage higher than the inverter can handle, reversed polarity, or a short in the string.
What the source says
Restart the inverter, and if it persists, contact the company
What you can do
Nothing on your side. Don't disconnect the panel connections while the sun is shining, as arcing is dangerous.
When to call a technician
In every case. The installer reviews the number of panels in each string and their connection.

Warning 207 Overcurrent on the USB port Try it yourself first

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What the source says
Unplug the USB memory or the monitoring device, then reconnect it after switching off
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

Warning 401 Communication fault with the meter Try it yourself first

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What the source says
Make sure the meter is working and check its connection to the inverter
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

Warning 404 EEPROM fault Try it yourself first

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What the source says
Restart the inverter, and if it persists, contact the company
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

Warning 405 Firmware versions don't match Needs a technician

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What the source says
Update the firmware to the correct version
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

Codes from a single source

We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.

Error 100 2.5 V reference voltage fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

Error 101 Communication fault Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

Error 102 Master and slave processor data mismatch Try it yourself first

What it means
A unit in a multi-unit system isn't in the state the system expects.
What the source says
Restart the inverter
What you can do
Make sure all units are powered and running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

Error 116 EEPROM fault Needs a technician

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

Error 117 Relay fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

Error 118 Model initialisation fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

Error 119 GFCI device damaged Needs a technician

What it means
The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
What you can do
Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
When to call a technician
If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.

Error 120 HCT current sensor fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

Error 121 The master processor isn't receiving from the slave Try it yourself first

What it means
A unit in a multi-unit system isn't in the state the system expects.
What the source says
Restart the inverter
What you can do
Make sure all units are powered and running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

Error 122 Internal bus voltage fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.