Fronius inverter error codes

79 codes, each with what it means, what you can safely try yourself, and when to call a technician. The company calls them status codes (State), and the first digit shows the fault category.

3 of the 79 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
102AC voltage highTry it yourself first
103AC voltage lowTry it yourself first
105AC frequency highTry it yourself first
106AC frequency lowTry it yourself first
107AC grid outside the allowed limitsTry it yourself first
108Islanding detectedNeeds a technician
112RCMU errorNeeds a technician
301AC overcurrentNeeds a technician
302DC overcurrentNeeds a technician
303Power stage overheatingTry it yourself first
304Internal temperature highTry it yourself first
306Panel output lowNot a fault
307Panel voltage lowNot a fault
308Intermediate circuit overvoltageNeeds a technician
309DC input voltage high on MPPT 1Needs a technician
313DC input voltage high on MPPT 2Needs a technician
401No communication with the power stageNeeds a technician
406Power stage temperature sensor faultNeeds a technician
407Internal temperature sensor faultNeeds a technician
408DC injection into the grid detectedNeeds a technician
412Constant voltage mode set incorrectlyNeeds a technician
415Safety shutdown activatedNeeds a technician
416No communication between the power stage and the controlNeeds a technician
417Hardware ID problemNeeds a technician
419Unique ID conflictNeeds a technician
421HID range errorNeeds a technician
425No communication with the power stageNeeds a technician
426Possible hardware faultNeeds a technician
427Possible hardware faultNeeds a technician
428Possible hardware faultNeeds a technician
431Software problemNeeds a technician
436Functional incompatibility between boardsNeeds a technician
437Power stage problemNeeds a technician
438Functional incompatibility between boardsNeeds a technician
443Intermediate circuit voltage low or asymmetricNeeds a technician
447Insulation faultNeeds a technician
448Neutral not connectedNeeds a technician
450Guard could not be foundNeeds a technician
456Anti-islanding function not working correctlyNeeds a technician
457Grid relay stuckNeeds a technician
459Insulation test signal recording errorNeeds a technician
460DSP voltage reference out of toleranceNeeds a technician
461DSP data memory faultNeeds a technician
462DC injection monitoring errorNeeds a technician
463AC polarity reversedNeeds a technician
474RCMU sensor faultNeeds a technician
475Panel earth faultNeeds a technician
476Driver supply voltage lowNeeds a technician
480Functional incompatibility between boardsNeeds a technician
481Functional incompatibility between boardsNeeds a technician
482Start-up not completedNeeds a technician
483Fixed UDC voltage on MPP2 out of limitsNeeds a technician
485CAN transmit buffer fullNeeds a technician
502Panel insulation errorNeeds a technician
509No energy fed into the grid in 24 hoursTry it yourself first
515Could not communicate with the filterNeeds a technician
516No communication with the storage unitNeeds a technician
517Power derating due to temperatureNot a fault
522DC1 input voltage lowNot a fault
523DC2 input voltage lowNot a fault
558Functional incompatibility between boardsNeeds a technician
560Power derating due to high frequencyNot a fault
566Arc detector switched offNeeds a technician
567Voltage-dependent power derating activeNot a fault
721EEPROM reinitialised or faultyNeeds a technician
731USB memory not supportedTry it yourself first
732Overcurrent on the USB memoryTry it yourself first
733No USB memory connectedTry it yourself first
734Update file not foundTry it yourself first
735Update file doesn't match the deviceTry it yourself first
736Read or write errorTry it yourself first
738Could not save the log fileTry it yourself first
743Error during the updateTry it yourself first
745Update file corruptedTry it yourself first
751Time lostTry it yourself first
752Clock module communication errorNeeds a technician
757Clock module hardware faultNeeds a technician
758Clock module in emergency modeNeeds a technician
766Emergency power derating activatedNeeds a technician

Every code explained

The panels generate dangerous voltage whenever light falls on them, even with the inverter switched off. Everything under “What you can do” is done without touching the panel cables.

102 AC voltage high Try it yourself first

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.
Note
Status codes for the Primo and Symo series

103 AC voltage low Try it yourself first

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.

105 AC frequency high Try it yourself first

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.

106 AC frequency low Try it yourself first

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.

107 AC grid outside the allowed limits Try it yourself first

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.

108 Islanding detected Needs a technician

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.

112 RCMU error Needs a technician

What it means
The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
What you can do
Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
When to call a technician
If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.

301 AC overcurrent Needs a technician

What it means
The current through the inverter is higher than it can handle.
What you can do
Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
When to call a technician
If it appears without large loads. There may be a short in the wiring or a fault in the inverter.

302 DC overcurrent Needs a technician

What it means
The current through the inverter is higher than it can handle.
What you can do
Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
When to call a technician
If it appears without large loads. There may be a short in the wiring or a fault in the inverter.

303 Power stage overheating Try it yourself first

What it means
The inverter got hotter than allowed, so it reduced its output or stopped.
What you can do
Make sure there is clear space around it for ventilation and it isn't in direct sun, and clean the dust from the vents.
When to call a technician
If it keeps happening with good ventilation. The internal fan or the temperature sensor may be faulty.

306 Panel output low Not a fault

What it means
An operating state, not a fault.
What you can do
Nothing needs fixing.
When to call a technician
If the status persists and prevents production for no clear reason.

307 Panel voltage low Not a fault

What it means
An operating state, not a fault.
What you can do
Nothing needs fixing.
When to call a technician
If the status persists and prevents production for no clear reason.

308 Intermediate circuit overvoltage Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

309 DC input voltage high on MPPT 1 Needs a technician

What it means
A problem connecting the panel strings: a voltage higher than the inverter can handle, reversed polarity, or a short in the string.
What you can do
Nothing on your side. Don't disconnect the panel connections while the sun is shining, as arcing is dangerous.
When to call a technician
In every case. The installer reviews the number of panels in each string and their connection.

313 DC input voltage high on MPPT 2 Needs a technician

What it means
A problem connecting the panel strings: a voltage higher than the inverter can handle, reversed polarity, or a short in the string.
What you can do
Nothing on your side. Don't disconnect the panel connections while the sun is shining, as arcing is dangerous.
When to call a technician
In every case. The installer reviews the number of panels in each string and their connection.

401 No communication with the power stage Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

408 DC injection into the grid detected Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

412 Constant voltage mode set incorrectly Needs a technician

What it means
A setting in the inverter doesn't suit the system connected to it.
What you can do
Don't change settings by trial and error.
When to call a technician
In every case. The installer reviews the intended setting.

415 Safety shutdown activated Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

416 No communication between the power stage and the control Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

417 Hardware ID problem Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

419 Unique ID conflict Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

421 HID range error Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

425 No communication with the power stage Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

426 Possible hardware fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

427 Possible hardware fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

428 Possible hardware fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

431 Software problem Needs a technician

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

436 Functional incompatibility between boards Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

437 Power stage problem Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

438 Functional incompatibility between boards Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

443 Intermediate circuit voltage low or asymmetric Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

447 Insulation fault Needs a technician

What it means
The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
What you can do
Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
When to call a technician
If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.

448 Neutral not connected Needs a technician

What it means
The AC side connection isn't sound: neutral or earth disconnected, or wires reversed.
What you can do
Nothing on your side except making sure the AC breaker is on.
When to call a technician
In every case. The neutral and earth connections are checked at the inverter and the distribution board.

450 Guard could not be found Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

456 Anti-islanding function not working correctly Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

457 Grid relay stuck Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

459 Insulation test signal recording error Needs a technician

What it means
The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
What you can do
Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
When to call a technician
If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.

460 DSP voltage reference out of tolerance Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

461 DSP data memory fault Needs a technician

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

462 DC injection monitoring error Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

463 AC polarity reversed Needs a technician

What it means
The AC side connection isn't sound: neutral or earth disconnected, or wires reversed.
What you can do
Nothing on your side except making sure the AC breaker is on.
When to call a technician
In every case. The neutral and earth connections are checked at the inverter and the distribution board.

474 RCMU sensor fault Needs a technician

What it means
The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
What you can do
Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
When to call a technician
If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.

475 Panel earth fault Needs a technician

What it means
The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
What you can do
Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
When to call a technician
If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.

476 Driver supply voltage low Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

480 Functional incompatibility between boards Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

481 Functional incompatibility between boards Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

482 Start-up not completed Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

483 Fixed UDC voltage on MPP2 out of limits Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

485 CAN transmit buffer full Needs a technician

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

502 Panel insulation error Needs a technician

What it means
The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
What you can do
Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
When to call a technician
If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.

509 No energy fed into the grid in 24 hours Try it yourself first

What it means
The power coming from the panels is less than enough to operate.
What the source says
Check the panels for shade, snow or dirt
What you can do
Normal at dawn, dusk and under heavy cloud. Clean the panels if they are dusty, and make sure the DC switch is on.
When to call a technician
If it appears in broad daylight with clean panels. There may be a damaged panel or connector in the string.

515 Could not communicate with the filter Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

516 No communication with the storage unit Needs a technician

What it means
A problem with the battery or its communication with the inverter.
What you can do
Make sure the battery breaker is on and the communication cable between it and the inverter is seated properly.
When to call a technician
If the code stays. The installer reviews the battery settings and voltage.

517 Power derating due to temperature Not a fault

What it means
An operating state, not a fault.
What you can do
Nothing needs fixing.
When to call a technician
If the status persists and prevents production for no clear reason.

522 DC1 input voltage low Not a fault

What it means
An operating state, not a fault.
What you can do
Nothing needs fixing.
When to call a technician
If the status persists and prevents production for no clear reason.

523 DC2 input voltage low Not a fault

What it means
An operating state, not a fault.
What you can do
Nothing needs fixing.
When to call a technician
If the status persists and prevents production for no clear reason.

558 Functional incompatibility between boards Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

560 Power derating due to high frequency Not a fault

What it means
An operating state, not a fault.
What you can do
Nothing needs fixing.
When to call a technician
If the status persists and prevents production for no clear reason.

566 Arc detector switched off Needs a technician

What it means
The inverter detected an electrical spark (arc) in the panel circuit, or the arc detector itself is faulty. Arcing is a known cause of fires in solar systems.
What you can do
Don't keep restarting, and don't touch the panel connections.
When to call a technician
In every case. The panel connections and cables are checked one by one.

567 Voltage-dependent power derating active Not a fault

What it means
An operating state, not a fault.
What you can do
Nothing needs fixing.
When to call a technician
If the status persists and prevents production for no clear reason.

721 EEPROM reinitialised or faulty Needs a technician

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

731 USB memory not supported Try it yourself first

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

732 Overcurrent on the USB memory Try it yourself first

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

733 No USB memory connected Try it yourself first

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

734 Update file not found Try it yourself first

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

735 Update file doesn't match the device Try it yourself first

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

736 Read or write error Try it yourself first

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

738 Could not save the log file Try it yourself first

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

743 Error during the update Try it yourself first

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

745 Update file corrupted Try it yourself first

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

751 Time lost Try it yourself first

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

752 Clock module communication error Needs a technician

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

757 Clock module hardware fault Needs a technician

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

758 Clock module in emergency mode Needs a technician

What it means
A fault in the inverter's software or memory or in its update process, not in the power itself.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. It needs a firmware update or a reset by the installer.

766 Emergency power derating activated Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

Codes from a single source

We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.

304 Internal temperature high Try it yourself first

What it means
The inverter got hotter than allowed, so it reduced its output or stopped.
What you can do
Make sure there is clear space around it for ventilation and it isn't in direct sun, and clean the dust from the vents.
When to call a technician
If it keeps happening with good ventilation. The internal fan or the temperature sensor may be faulty.

406 Power stage temperature sensor fault Needs a technician

What it means
The inverter got hotter than allowed, so it reduced its output or stopped.
What you can do
Make sure there is clear space around it for ventilation and it isn't in direct sun, and clean the dust from the vents.
When to call a technician
If it keeps happening with good ventilation. The internal fan or the temperature sensor may be faulty.

407 Internal temperature sensor fault Needs a technician

What it means
The inverter got hotter than allowed, so it reduced its output or stopped.
What you can do
Make sure there is clear space around it for ventilation and it isn't in direct sun, and clean the dust from the vents.
When to call a technician
If it keeps happening with good ventilation. The internal fan or the temperature sensor may be faulty.