Deye inverter error codes
27 codes, each with what it means, what you can safely try yourself, and when to call a technician. Its codes are F followed by two digits, for hybrid inverters.
2 of the 27 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.
A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.
Quick table
| Code | Meaning | Who handles it |
|---|
F08 | GFDI relay fault | Needs a technician |
F13 | Operating mode changed | Try it yourself first |
F18 | AC overcurrent (hardware) | Try it yourself first |
F20 | DC overcurrent (hardware) | Try it yourself first |
F22 | Emergency stop | Needs a technician |
F23 | Instantaneous AC leakage current too high | Try it yourself first |
F24 | DC circuit insulation failure | Needs a technician |
F26 | DC bus unbalanced | Try it yourself first |
F29 | CANBus fault in parallel operation | Needs a technician |
F34 | AC overcurrent | Try it yourself first |
F35 | No grid | Try it yourself first |
F41 | Parallel system stopped | Needs a technician |
F42 | AC line voltage low | Try it yourself first |
F47 | AC frequency high | Try it yourself first |
F48 | AC frequency low | Try it yourself first |
F56 | DC bus voltage very low | Try it yourself first |
F58 | BMS communication fault | Needs a technician |
F63 | ARC fault | Needs a technician |
F64 | Heat sink overheating | Try it yourself first |
F01 | Panel input polarity reversed | Needs a technician |
F07 | DC side start-up failed | Try it yourself first |
F15 | AC overcurrent (software) | Try it yourself first |
F16 | AC leakage current | Needs a technician |
F21 | Internal bus overcurrent | Needs a technician |
F46 | Backup battery fault | Needs a technician |
F55 | DC bus voltage very high | Needs a technician |
F62 | Stopped by DRM command | Needs a technician |
Every code explained
The panels generate dangerous voltage whenever light falls on them, even with the inverter switched off. Everything under “What you can do” is done without touching the panel cables.
F13 Operating mode changed Try it yourself first
- What it means
- The inverter changed its operating mode, such as switching between the grid and the battery. Usually a passing code.
- What the source says
- Restart the system
- What you can do
- Wait, as it disappears by itself. If it stays, restart: switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If it happens often along with supply interruptions.
F18 AC overcurrent (hardware) Try it yourself first
- What it means
- The current through the inverter is higher than it can handle.
- What the source says
- Reduce the load on the backup output and restart
- What you can do
- Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
- When to call a technician
- If it appears without large loads. There may be a short in the wiring or a fault in the inverter.
F20 DC overcurrent (hardware) Try it yourself first
- What it means
- The current through the inverter is higher than it can handle.
- What the source says
- Check the panel and battery connections and reduce the load
- What you can do
- Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
- When to call a technician
- If it appears without large loads. There may be a short in the wiring or a fault in the inverter.
F22 Emergency stop Needs a technician
- What it means
- The inverter was stopped by an external command: an emergency stop button, or a remote control signal.
- What the source says
- Refer to the installer
- What you can do
- Make sure the emergency stop button is released if one is fitted, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code stays with no visible stop command.
F23 Instantaneous AC leakage current too high Try it yourself first
- What it means
- The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
- What the source says
- Check the panel cable earthing and restart
- What you can do
- Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
- When to call a technician
- If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.
F24 DC circuit insulation failure Needs a technician
- What it means
- The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
- What the source says
- Check the panel connection and the earth wire
- What you can do
- Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
- When to call a technician
- If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.
F26 DC bus unbalanced Try it yourself first
- What it means
- An internal fault the inverter detected in one of its circuits.
- What the source says
- Restart the system two or three times
- What you can do
- Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
F29 CANBus fault in parallel operation Needs a technician
- What it means
- The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
- What the source says
- Check the parallel cable and the communication address
- What you can do
- Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code stays. The installer reviews the link settings between the units.
F34 AC overcurrent Try it yourself first
- What it means
- The current through the inverter is higher than it can handle.
- What the source says
- Make sure the backup load is within the allowed capacity
- What you can do
- Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
- When to call a technician
- If it appears without large loads. There may be a short in the wiring or a fault in the inverter.
F41 Parallel system stopped Needs a technician
- What it means
- The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
- What you can do
- Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code stays. The installer reviews the link settings between the units.
F42 AC line voltage low Try it yourself first
- What it means
- The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
- What you can do
- Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
- When to call a technician
- If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.
F47 AC frequency high Try it yourself first
- What it means
- The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
- What you can do
- Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
- When to call a technician
- If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.
F48 AC frequency low Try it yourself first
- What it means
- The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
- What you can do
- Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
- When to call a technician
- If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.
F56 DC bus voltage very low Try it yourself first
- What it means
- An internal fault the inverter detected in one of its circuits.
- What the source says
- Charge the battery from the panels or the grid
- What you can do
- Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
F58 BMS communication fault Needs a technician
- What it means
- A problem with the battery or its communication with the inverter.
- What the source says
- Check the BMS connection
- What you can do
- Make sure the battery breaker is on and the communication cable between it and the inverter is seated properly.
- When to call a technician
- If the code stays. The installer reviews the battery settings and voltage.
F63 ARC fault Needs a technician
- What it means
- The inverter detected an electrical spark (arc) in the panel circuit, or the arc detector itself is faulty. Arcing is a known cause of fires in solar systems.
- What the source says
- Check the panel cable connections
- What you can do
- Don't keep restarting, and don't touch the panel connections.
- When to call a technician
- In every case. The panel connections and cables are checked one by one.
F64 Heat sink overheating Try it yourself first
- What it means
- The inverter got hotter than allowed, so it reduced its output or stopped.
- What the source says
- Switch off the inverter for 10 minutes, then switch it on
- What you can do
- Make sure there is clear space around it for ventilation and it isn't in direct sun, and clean the dust from the vents.
- When to call a technician
- If it keeps happening with good ventilation. The internal fan or the temperature sensor may be faulty.
F01 Panel input polarity reversed Needs a technician
- What it means
- A problem connecting the panel strings: a voltage higher than the inverter can handle, reversed polarity, or a short in the string.
- What the source says
- Check the polarity of the panel connections
- What you can do
- Nothing on your side. Don't disconnect the panel connections while the sun is shining, as arcing is dangerous.
- When to call a technician
- In every case. The installer reviews the number of panels in each string and their connection.
F07 DC side start-up failed Try it yourself first
- What it means
- An internal fault the inverter detected in one of its circuits.
- What the source says
- The internal bus voltage isn't building from the panels or the battery. Restart
- What you can do
- Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
F15 AC overcurrent (software) Try it yourself first
- What it means
- The current through the inverter is higher than it can handle.
- What the source says
- Make sure the load power is within the limit, then restart
- What you can do
- Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
- When to call a technician
- If it appears without large loads. There may be a short in the wiring or a fault in the inverter.
F16 AC leakage current Needs a technician
- What it means
- The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
- What the source says
- Check the panel cable earthing and restart two or three times
- What you can do
- Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
- When to call a technician
- If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.
F21 Internal bus overcurrent Needs a technician
- What it means
- The current through the inverter is higher than it can handle.
- What the source says
- Check the panel input and the battery current setting, then restart
- What you can do
- Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
- When to call a technician
- If it appears without large loads. There may be a short in the wiring or a fault in the inverter.
F46 Backup battery fault Needs a technician
- What it means
- A problem with the battery or its communication with the inverter.
- What the source says
- Check each battery's status: voltage, state of charge and matching settings
- What you can do
- Make sure the battery breaker is on and the communication cable between it and the inverter is seated properly.
- When to call a technician
- If the code stays. The installer reviews the battery settings and voltage.
F55 DC bus voltage very high Needs a technician
- What it means
- An internal fault the inverter detected in one of its circuits.
- What the source says
- Make sure the battery voltage and the panel voltage are within the limit
- What you can do
- Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
F62 Stopped by DRM command Needs a technician
- What it means
- The inverter was stopped by an external command: an emergency stop button, or a remote control signal.
- What the source says
- Check the status of the DRM function and restart
- What you can do
- Make sure the emergency stop button is released if one is fitted, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code stays with no visible stop command.
Codes from a single source
We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.
F08 GFDI relay fault Needs a technician
- What it means
- An internal fault the inverter detected in one of its circuits.
- What you can do
- Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
F35 No grid Try it yourself first
- What it means
- The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
- What the source says
- Confirm the grid outage and check the connection
- What you can do
- Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
- When to call a technician
- If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.