Home ‹ Solar inverters ‹ Deye

Deye inverter error codes

27 codes, each with what it means, what you can safely try yourself, and when to call a technician. Its codes are F followed by two digits, for hybrid inverters.

2 of the 27 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
F08GFDI relay faultNeeds a technician
F13Operating mode changedTry it yourself first
F18AC overcurrent (hardware)Try it yourself first
F20DC overcurrent (hardware)Try it yourself first
F22Emergency stopNeeds a technician
F23Instantaneous AC leakage current too highTry it yourself first
F24DC circuit insulation failureNeeds a technician
F26DC bus unbalancedTry it yourself first
F29CANBus fault in parallel operationNeeds a technician
F34AC overcurrentTry it yourself first
F35No gridTry it yourself first
F41Parallel system stoppedNeeds a technician
F42AC line voltage lowTry it yourself first
F47AC frequency highTry it yourself first
F48AC frequency lowTry it yourself first
F56DC bus voltage very lowTry it yourself first
F58BMS communication faultNeeds a technician
F63ARC faultNeeds a technician
F64Heat sink overheatingTry it yourself first
F01Panel input polarity reversedNeeds a technician
F07DC side start-up failedTry it yourself first
F15AC overcurrent (software)Try it yourself first
F16AC leakage currentNeeds a technician
F21Internal bus overcurrentNeeds a technician
F46Backup battery faultNeeds a technician
F55DC bus voltage very highNeeds a technician
F62Stopped by DRM commandNeeds a technician

Every code explained

The panels generate dangerous voltage whenever light falls on them, even with the inverter switched off. Everything under “What you can do” is done without touching the panel cables.

F13 Operating mode changed Try it yourself first

What it means
The inverter changed its operating mode, such as switching between the grid and the battery. Usually a passing code.
What the source says
Restart the system
What you can do
Wait, as it disappears by itself. If it stays, restart: switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If it happens often along with supply interruptions.

F18 AC overcurrent (hardware) Try it yourself first

What it means
The current through the inverter is higher than it can handle.
What the source says
Reduce the load on the backup output and restart
What you can do
Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
When to call a technician
If it appears without large loads. There may be a short in the wiring or a fault in the inverter.

F20 DC overcurrent (hardware) Try it yourself first

What it means
The current through the inverter is higher than it can handle.
What the source says
Check the panel and battery connections and reduce the load
What you can do
Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
When to call a technician
If it appears without large loads. There may be a short in the wiring or a fault in the inverter.

F22 Emergency stop Needs a technician

What it means
The inverter was stopped by an external command: an emergency stop button, or a remote control signal.
What the source says
Refer to the installer
What you can do
Make sure the emergency stop button is released if one is fitted, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays with no visible stop command.

F23 Instantaneous AC leakage current too high Try it yourself first

What it means
The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
What the source says
Check the panel cable earthing and restart
What you can do
Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
When to call a technician
If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.

F24 DC circuit insulation failure Needs a technician

What it means
The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
What the source says
Check the panel connection and the earth wire
What you can do
Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
When to call a technician
If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.

F26 DC bus unbalanced Try it yourself first

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Restart the system two or three times
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

F29 CANBus fault in parallel operation Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What the source says
Check the parallel cable and the communication address
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

F34 AC overcurrent Try it yourself first

What it means
The current through the inverter is higher than it can handle.
What the source says
Make sure the backup load is within the allowed capacity
What you can do
Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
When to call a technician
If it appears without large loads. There may be a short in the wiring or a fault in the inverter.

F41 Parallel system stopped Needs a technician

What it means
The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
What you can do
Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays. The installer reviews the link settings between the units.

F42 AC line voltage low Try it yourself first

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.

F47 AC frequency high Try it yourself first

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.

F48 AC frequency low Try it yourself first

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.

F56 DC bus voltage very low Try it yourself first

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Charge the battery from the panels or the grid
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

F58 BMS communication fault Needs a technician

What it means
A problem with the battery or its communication with the inverter.
What the source says
Check the BMS connection
What you can do
Make sure the battery breaker is on and the communication cable between it and the inverter is seated properly.
When to call a technician
If the code stays. The installer reviews the battery settings and voltage.

F63 ARC fault Needs a technician

What it means
The inverter detected an electrical spark (arc) in the panel circuit, or the arc detector itself is faulty. Arcing is a known cause of fires in solar systems.
What the source says
Check the panel cable connections
What you can do
Don't keep restarting, and don't touch the panel connections.
When to call a technician
In every case. The panel connections and cables are checked one by one.

F64 Heat sink overheating Try it yourself first

What it means
The inverter got hotter than allowed, so it reduced its output or stopped.
What the source says
Switch off the inverter for 10 minutes, then switch it on
What you can do
Make sure there is clear space around it for ventilation and it isn't in direct sun, and clean the dust from the vents.
When to call a technician
If it keeps happening with good ventilation. The internal fan or the temperature sensor may be faulty.

F01 Panel input polarity reversed Needs a technician

What it means
A problem connecting the panel strings: a voltage higher than the inverter can handle, reversed polarity, or a short in the string.
What the source says
Check the polarity of the panel connections
What you can do
Nothing on your side. Don't disconnect the panel connections while the sun is shining, as arcing is dangerous.
When to call a technician
In every case. The installer reviews the number of panels in each string and their connection.

F07 DC side start-up failed Try it yourself first

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
The internal bus voltage isn't building from the panels or the battery. Restart
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

F15 AC overcurrent (software) Try it yourself first

What it means
The current through the inverter is higher than it can handle.
What the source says
Make sure the load power is within the limit, then restart
What you can do
Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
When to call a technician
If it appears without large loads. There may be a short in the wiring or a fault in the inverter.

F16 AC leakage current Needs a technician

What it means
The inverter detected current leaking to earth from the panel side or its cables, so it stopped itself to protect you. Common after rain or with a cracked cable.
What the source says
Check the panel cable earthing and restart two or three times
What you can do
Don't touch the panels, their cables or their frames. If it appears in the morning with dew and disappears by itself, just keep an eye on it.
When to call a technician
If it keeps happening or doesn't clear. Insulation testing needs special equipment, and the panel voltage is lethal.

F21 Internal bus overcurrent Needs a technician

What it means
The current through the inverter is higher than it can handle.
What the source says
Check the panel input and the battery current setting, then restart
What you can do
Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
When to call a technician
If it appears without large loads. There may be a short in the wiring or a fault in the inverter.

F46 Backup battery fault Needs a technician

What it means
A problem with the battery or its communication with the inverter.
What the source says
Check each battery's status: voltage, state of charge and matching settings
What you can do
Make sure the battery breaker is on and the communication cable between it and the inverter is seated properly.
When to call a technician
If the code stays. The installer reviews the battery settings and voltage.

F55 DC bus voltage very high Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What the source says
Make sure the battery voltage and the panel voltage are within the limit
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

F62 Stopped by DRM command Needs a technician

What it means
The inverter was stopped by an external command: an emergency stop button, or a remote control signal.
What the source says
Check the status of the DRM function and restart
What you can do
Make sure the emergency stop button is released if one is fitted, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code stays with no visible stop command.

Codes from a single source

We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.

F08 GFDI relay fault Needs a technician

What it means
An internal fault the inverter detected in one of its circuits.
What you can do
Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
When to call a technician
If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.

F35 No grid Try it yourself first

What it means
The inverter can't find grid power, or finds its voltage or frequency outside the allowed limit, so it disconnects until it returns.
What the source says
Confirm the grid outage and check the connection
What you can do
Make sure the inverter's AC breaker is on and there is power in the house. If the grid is fluctuating, wait; it reconnects by itself.
When to call a technician
If it keeps happening with a stable grid. The grid limits in the settings may need adjusting, or the AC connection checked.