Home ‹ Solar inverters ‹ Axpert / Voltronic
Axpert (Voltronic) inverter error codes
19 codes, each with what it means, what you can safely try yourself, and when to call a technician.
11 of the 19 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.
A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.
Quick table
| Code | Meaning | Who handles it |
|---|
04 | Undervoltage | Try it yourself first |
07 | Overload | Try it yourself first |
32 | Communication lost | Needs a technician |
61 | Communication with the Pylontech battery lost | Needs a technician |
01 | Fan fault | Needs a technician |
02 | Internal components damaged | Needs a technician |
03 | Battery overcharged | Needs a technician |
05 | Output short circuit | Try it yourself first |
06 | Abnormal output voltage (below 190 or above 260 V) | Needs a technician |
08 | Internal component temperature above 120 °C | Try it yourself first |
09 | Battery disconnected | Try it yourself first |
11 | Main relay fault | Needs a technician |
51 | Overcurrent or a sudden voltage surge | Try it yourself first |
52 | Internal bus voltage low | Needs a technician |
53 | Inverter soft-start failed | Needs a technician |
55 | DC voltage too high on the AC output | Needs a technician |
56 | Battery not connected | Try it yourself first |
57 | Current sensor fault | Needs a technician |
58 | Output voltage low | Try it yourself first |
Every code explained
The panels generate dangerous voltage whenever light falls on them, even with the inverter switched off. Everything under “What you can do” is done without touching the panel cables.
07 Overload Try it yourself first
- What it means
- The current through the inverter is higher than it can handle.
- What the source says
- Reduce the loads
- What you can do
- Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
- When to call a technician
- If it appears without large loads. There may be a short in the wiring or a fault in the inverter.
01 Fan fault Needs a technician
- What it means
- The cooling fan isn't turning properly.
- What you can do
- Switch off the inverter, see whether anything is blocking the fan opening, and clean the dust from outside.
- When to call a technician
- If the code stays. The fan is replaced.
02 Internal components damaged Needs a technician
- What it means
- An internal fault the inverter detected in one of its circuits.
- What you can do
- Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
03 Battery overcharged Needs a technician
- What it means
- A problem with the battery or its communication with the inverter.
- What you can do
- Make sure the battery breaker is on and the communication cable between it and the inverter is seated properly.
- When to call a technician
- If the code stays. The installer reviews the battery settings and voltage.
05 Output short circuit Try it yourself first
- What it means
- The current through the inverter is higher than it can handle.
- What the source says
- Disconnect the loads and check the connections
- What you can do
- Disconnect the large loads, then restart, and switch them on one at a time afterwards to find which one is the cause.
- When to call a technician
- If it appears without large loads. There may be a short in the wiring or a fault in the inverter.
06 Abnormal output voltage (below 190 or above 260 V) Needs a technician
- What it means
- An internal fault the inverter detected in one of its circuits.
- What you can do
- Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
08 Internal component temperature above 120 °C Try it yourself first
- What it means
- The inverter got hotter than allowed, so it reduced its output or stopped.
- What the source says
- Make sure there is ventilation around the inverter
- What you can do
- Make sure there is clear space around it for ventilation and it isn't in direct sun, and clean the dust from the vents.
- When to call a technician
- If it keeps happening with good ventilation. The internal fan or the temperature sensor may be faulty.
09 Battery disconnected Try it yourself first
- What it means
- A problem with the battery or its communication with the inverter.
- What the source says
- Check the battery connection
- What you can do
- Make sure the battery breaker is on and the communication cable between it and the inverter is seated properly.
- When to call a technician
- If the code stays. The installer reviews the battery settings and voltage.
Codes from a single source
We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.
04 Undervoltage Try it yourself first
- What it means
- An internal fault the inverter detected in one of its circuits.
- What you can do
- Switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code comes back after restarting. Note the code and the time it appeared, and send them to the installer.
- Note
- The source is a forum discussion, not a complete list
32 Communication lost Needs a technician
- What it means
- The system's units aren't exchanging data properly: one inverter with another, or with the meter or the monitoring unit.
- What you can do
- Make sure the communication cables are seated in their ports and all units are running, then switch the inverter off in order: the AC breaker first, then the DC switch, wait five minutes, then switch it on in the reverse order.
- When to call a technician
- If the code stays. The installer reviews the link settings between the units.
61 Communication with the Pylontech battery lost Needs a technician
- What it means
- A problem with the battery or its communication with the inverter.
- What you can do
- Make sure the battery breaker is on and the communication cable between it and the inverter is seated properly.
- When to call a technician
- If the code stays. The installer reviews the battery settings and voltage.
11 Main relay fault Needs a technician
- What it means
- The relay that switches between mains power and the battery isn't working.
- What you can do
- Switch off the inverter and disconnect the battery and the mains for two minutes, then restart.
- When to call a technician
- If the code comes back. The relay is a part on the board that a technician replaces.
51 Overcurrent or a sudden voltage surge Try it yourself first
- What it means
- The inverter detected a sudden current higher than its capacity.
- What you can do
- Disconnect large loads such as the air conditioner, water heater and pump, then restart the inverter and add them one at a time.
- When to call a technician
- If the code returns with no loads.
52 Internal bus voltage low Needs a technician
- What it means
- The voltage inside the inverter is lower than required.
- What you can do
- Make sure the battery cables are tight and clean, then restart the inverter.
- When to call a technician
- If the code comes back.
53 Inverter soft-start failed Needs a technician
- What it means
- The inverter couldn't start up properly.
- What you can do
- Switch off the inverter and disconnect the battery for two minutes, then restart.
- When to call a technician
- If the code comes back.
55 DC voltage too high on the AC output Needs a technician
- What it means
- There is a DC voltage on the AC output higher than allowed.
- What you can do
- Switch off the inverter and disconnect the battery for two minutes, then restart.
- When to call a technician
- If the code comes back.
56 Battery not connected Try it yourself first
- What it means
- The inverter can't see the battery.
- What you can do
- Switch off the inverter, and make sure the battery cables are tight and the breaker or fuse between it and the inverter is working.
- When to call a technician
- If the connections are sound and the code stays.
57 Current sensor fault Needs a technician
- What it means
- The current sensor inside the inverter isn't giving a correct reading.
- What you can do
- Switch off the inverter and disconnect the battery for two minutes, then restart.
- When to call a technician
- If the code comes back.
58 Output voltage low Try it yourself first
- What it means
- The power coming out of the inverter is lower than required.
- What you can do
- Reduce the loads, then restart the inverter.
- When to call a technician
- If the code returns with light loads.