Home ‹ Water heaters and boilers ‹ Viessmann

Viessmann water heater error codes

26 codes, each with what it means, what you can safely try yourself, and when to call a technician.

25 of the 26 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
F2Overheating stopped the heaterNeeds a technician
F3Flame detected before the burner startedNeeds a technician
F4No flame detected after ignitionNeeds a technician
F5Not enough gas arriving to light the flame, and the gas pressure switch isn't respondingTry it yourself first
F8Gas valve relay not respondingNeeds a technician
F9The flue fan is turning slower than requiredNeeds a technician
FAThe flue fan didn't stop after operation endedNeeds a technician
FCFlue fan control circuit faultNeeds a technician
0CLow supply voltageTry it yourself first
10Outdoor temperature sensor reading short circuitNeeds a technician
18Outdoor temperature sensor reading open circuitNeeds a technician
20Supply water temperature sensor reading short circuitNeeds a technician
28Supply water temperature sensor reading open circuitNeeds a technician
30Heater water temperature sensor reading short circuitNeeds a technician
38Heater water temperature sensor reading open circuitNeeds a technician
50Hot water temperature sensor reading short circuitNeeds a technician
51Hot water temperature sensor reading open circuitNeeds a technician
58Hot water cylinder temperature sensor reading short circuitNeeds a technician
59Hot water cylinder temperature sensor reading open circuitNeeds a technician
b0Flue gas temperature sensor reading short circuitNeeds a technician
b7Fault in the burner control unit's electronic boardNeeds a technician
E4Weak or missing flame signalNeeds a technician
E5The flame measuring circuit on the board is giving a false signalNeeds a technician
62Overheating: the high-limit thermostat trippedNeeds a technician
74Circuit water pressure below the required limitTry it yourself first
89Circulation pump blocked, water isn't circulatingNeeds a technician

Every code explained

If you smell gas, don't switch on the heater or any electrical switch: close the main valve, open the windows, leave the premises, and call a specialist from outside.

F5 Not enough gas arriving to light the flame, and the gas pressure switch isn't responding Try it yourself first

What it means
The heater isn't getting enough gas, can't light the flame, or loses it after lighting.
What the source says
Insufficient incoming gas pressure
What you can do
Make sure the gas valve is fully open and the cylinder or meter has gas. Try lighting a cooker burner to see whether gas is arriving at all, then restart the heater.
When to call a technician
If gas is arriving and the code stays. The ignition electrode, flame sensor and gas valve are checked by a specialist; don't take apart anything in the gas path yourself.

Codes from a single source

We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.

F2 Overheating stopped the heater Needs a technician

What it means
The heater shut itself down to protect against overheating.
What the source says
High-limit thermostat tripped
What you can do
Let it cool for half an hour, then switch it back on, and make sure the hot water tap delivers water at normal pressure.
When to call a technician
If the code keeps appearing. Overheating is usually caused by limescale in the heat exchanger or poor circulation, and needs cleaning or checking.

F3 Flame detected before the burner started Needs a technician

What it means
The heater isn't getting enough gas, can't light the flame, or loses it after lighting.
What the source says
False flame signal
What you can do
Make sure the gas valve is fully open and the cylinder or meter has gas. Try lighting a cooker burner to see whether gas is arriving at all, then restart the heater.
When to call a technician
If gas is arriving and the code stays. The ignition electrode, flame sensor and gas valve are checked by a specialist; don't take apart anything in the gas path yourself.

F4 No flame detected after ignition Needs a technician

What it means
The heater isn't getting enough gas, can't light the flame, or loses it after lighting.
What the source says
Ignition doesn't hold
What you can do
Make sure the gas valve is fully open and the cylinder or meter has gas. Try lighting a cooker burner to see whether gas is arriving at all, then restart the heater.
When to call a technician
If gas is arriving and the code stays. The ignition electrode, flame sensor and gas valve are checked by a specialist; don't take apart anything in the gas path yourself.

F8 Gas valve relay not responding Needs a technician

What it means
A fault in the electronic board or the gas valve: an illogical signal or a control that doesn't respond.
What the source says
A fault in the board or the valve
What you can do
Unplug the heater for a minute, then switch it back on. If the code returns, don't try again.
When to call a technician
In almost every case. The board and the gas valve are checked with measuring tools, and only a specialist should work on the gas path.

F9 The flue fan is turning slower than required Needs a technician

What it means
The heater can't confirm that the exhaust is getting out properly, so it shuts down to protect you from combustion gases.
What the source says
Weak fan motor
What you can do
Don't run the heater while this code is showing. Check the flue from outside: is anything blocking it, or a bird's nest? Make sure the outer cap is in place.
When to call a technician
If the flue is clear and the code stays. The air pressure switch and the fan are checked by a specialist; ignoring this code risks poisoning.

FA The flue fan didn't stop after operation ended Needs a technician

What it means
The heater can't confirm that the exhaust is getting out properly, so it shuts down to protect you from combustion gases.
What the source says
The fan control circuit isn't responding
What you can do
Don't run the heater while this code is showing. Check the flue from outside: is anything blocking it, or a bird's nest? Make sure the outer cap is in place.
When to call a technician
If the flue is clear and the code stays. The air pressure switch and the fan are checked by a specialist; ignoring this code risks poisoning.

FC Flue fan control circuit fault Needs a technician

What it means
The heater can't confirm that the exhaust is getting out properly, so it shuts down to protect you from combustion gases.
What the source says
The fan control unit is faulty
What you can do
Don't run the heater while this code is showing. Check the flue from outside: is anything blocking it, or a bird's nest? Make sure the outer cap is in place.
When to call a technician
If the flue is clear and the code stays. The air pressure switch and the fan are checked by a specialist; ignoring this code risks poisoning.

0C Low supply voltage Try it yourself first

What it means
The power reaching the heater isn't at the required level.
What the source says
Supply voltage below the limit
What you can do
Make sure the breaker hasn't tripped and the household power is normal, and plug the heater straight into a socket without an extension lead.
When to call a technician
If it keeps happening with normal household power.

10 Outdoor temperature sensor reading short circuit Needs a technician

What it means
One of the heater's sensors is reading out of range, or its wire is disconnected.
What the source says
Faulty outdoor sensor
What you can do
Unplug the heater for a minute, then switch it back on.
When to call a technician
If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.

18 Outdoor temperature sensor reading open circuit Needs a technician

What it means
One of the heater's sensors is reading out of range, or its wire is disconnected.
What the source says
Outdoor sensor disconnected
What you can do
Unplug the heater for a minute, then switch it back on.
When to call a technician
If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.

20 Supply water temperature sensor reading short circuit Needs a technician

What it means
One of the heater's sensors is reading out of range, or its wire is disconnected.
What the source says
Faulty temperature sensor
What you can do
Unplug the heater for a minute, then switch it back on.
When to call a technician
If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.

28 Supply water temperature sensor reading open circuit Needs a technician

What it means
One of the heater's sensors is reading out of range, or its wire is disconnected.
What the source says
Temperature sensor disconnected
What you can do
Unplug the heater for a minute, then switch it back on.
When to call a technician
If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.

30 Heater water temperature sensor reading short circuit Needs a technician

What it means
One of the heater's sensors is reading out of range, or its wire is disconnected.
What the source says
Faulty temperature sensor
What you can do
Unplug the heater for a minute, then switch it back on.
When to call a technician
If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.

38 Heater water temperature sensor reading open circuit Needs a technician

What it means
One of the heater's sensors is reading out of range, or its wire is disconnected.
What the source says
Temperature sensor disconnected
What you can do
Unplug the heater for a minute, then switch it back on.
When to call a technician
If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.

50 Hot water temperature sensor reading short circuit Needs a technician

What it means
One of the heater's sensors is reading out of range, or its wire is disconnected.
What the source says
Faulty temperature sensor
What you can do
Unplug the heater for a minute, then switch it back on.
When to call a technician
If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.

51 Hot water temperature sensor reading open circuit Needs a technician

What it means
One of the heater's sensors is reading out of range, or its wire is disconnected.
What the source says
Temperature sensor disconnected
What you can do
Unplug the heater for a minute, then switch it back on.
When to call a technician
If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.

58 Hot water cylinder temperature sensor reading short circuit Needs a technician

What it means
One of the heater's sensors is reading out of range, or its wire is disconnected.
What the source says
Faulty temperature sensor
What you can do
Unplug the heater for a minute, then switch it back on.
When to call a technician
If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.

59 Hot water cylinder temperature sensor reading open circuit Needs a technician

What it means
One of the heater's sensors is reading out of range, or its wire is disconnected.
What the source says
Temperature sensor disconnected
What you can do
Unplug the heater for a minute, then switch it back on.
When to call a technician
If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.

b0 Flue gas temperature sensor reading short circuit Needs a technician

What it means
One of the heater's sensors is reading out of range, or its wire is disconnected.
What the source says
Faulty temperature sensor
What you can do
Unplug the heater for a minute, then switch it back on.
When to call a technician
If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.

b7 Fault in the burner control unit's electronic board Needs a technician

What it means
A fault in the electronic board or the gas valve: an illogical signal or a control that doesn't respond.
What the source says
The control unit isn't working
What you can do
Unplug the heater for a minute, then switch it back on. If the code returns, don't try again.
When to call a technician
In almost every case. The board and the gas valve are checked with measuring tools, and only a specialist should work on the gas path.

E4 Weak or missing flame signal Needs a technician

What it means
The heater isn't getting enough gas, can't light the flame, or loses it after lighting.
What the source says
Unstable flame or a dirty ionisation sensor
What you can do
Make sure the gas valve is fully open and the cylinder or meter has gas. Try lighting a cooker burner to see whether gas is arriving at all, then restart the heater.
When to call a technician
If gas is arriving and the code stays. The ignition electrode, flame sensor and gas valve are checked by a specialist; don't take apart anything in the gas path yourself.

E5 The flame measuring circuit on the board is giving a false signal Needs a technician

What it means
A fault in the electronic board or the gas valve: an illogical signal or a control that doesn't respond.
What the source says
Ionisation circuit fault
What you can do
Unplug the heater for a minute, then switch it back on. If the code returns, don't try again.
When to call a technician
In almost every case. The board and the gas valve are checked with measuring tools, and only a specialist should work on the gas path.

62 Overheating: the high-limit thermostat tripped Needs a technician

What it means
The heater shut itself down to protect against overheating.
What the source says
Poor water circulation or limescale
What you can do
Let it cool for half an hour, then switch it back on, and make sure the hot water tap delivers water at normal pressure.
When to call a technician
If the code keeps appearing. Overheating is usually caused by limescale in the heat exchanger or poor circulation, and needs cleaning or checking.

74 Circuit water pressure below the required limit Try it yourself first

What it means
There isn't enough water in the heater, or it isn't circulating properly.
What the source says
Low system water
What you can do
Open a hot water tap and make sure water arrives at normal pressure. If your heater is a sealed-pressure type, check the pressure gauge and bring it back to between 1 and 1.5 bar as the manual explains.
When to call a technician
If the pressure is normal and the code stays. The pump, the pressure sensor or an internal blockage needs checking.

89 Circulation pump blocked, water isn't circulating Needs a technician

What it means
There isn't enough water in the heater, or it isn't circulating properly.
What the source says
Pump stuck or faulty
What you can do
Open a hot water tap and make sure water arrives at normal pressure. If your heater is a sealed-pressure type, check the pressure gauge and bring it back to between 1 and 1.5 bar as the manual explains.
When to call a technician
If the pressure is normal and the code stays. The pump, the pressure sensor or an internal blockage needs checking.

Sources