Home ‹ Water heaters and boilers ‹ Vaillant
Vaillant water heater error codes
13 codes, each with what it means, what you can safely try yourself, and when to call a technician. The codes are F followed by a number with a dot (such as F.28), from the ecoTEC manuals.
5 of the 13 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.
A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.
Quick table
| Code | Meaning | Who handles it |
|---|
F.22 | Low water in the appliance or risk of dry firing | Try it yourself first |
F.24 | Water circulation fault inside the appliance | Needs a technician |
F.28 | Ignition failure after several attempts | Try it yourself first |
F.29 | Flame went out during operation | Try it yourself first |
F.54 | Insufficient gas supply at ignition | Try it yourself first |
F.20 | Maximum temperature exceeded inside the appliance | Needs a technician |
F.56 | Gas mass flow sensor regulation fault | Needs a technician |
F.60 | Gas valve control fault | Needs a technician |
F.61 | Gas valve circuit fault | Needs a technician |
F.62 | Gas valve slow to close after the flame went out | Needs a technician |
F.75 | The appliance doesn't detect a pressure rise when the pump runs | Needs a technician |
F.00 | Heating flow temperature sensor fault | Needs a technician |
F.01 | Return temperature sensor fault | Needs a technician |
Every code explained
If you smell gas, don't switch on the heater or any electrical switch: close the main valve, open the windows, leave the premises, and call a specialist from outside.
F.22 Low water in the appliance or risk of dry firing Try it yourself first
- What it means
- There isn't enough water in the heater, or it isn't circulating properly.
- What the source says
- Water pressure in the appliance very low, or the pressure sensor isn't reading
- What you can do
- Open a hot water tap and make sure water arrives at normal pressure. If your heater is a sealed-pressure type, check the pressure gauge and bring it back to between 1 and 1.5 bar as the manual explains.
- When to call a technician
- If the pressure is normal and the code stays. The pump, the pressure sensor or an internal blockage needs checking.
F.24 Water circulation fault inside the appliance Needs a technician
- What it means
- There isn't enough water in the heater, or it isn't circulating properly.
- What the source says
- Water heating abnormally fast due to poor circulation or a pump fault
- What you can do
- Open a hot water tap and make sure water arrives at normal pressure. If your heater is a sealed-pressure type, check the pressure gauge and bring it back to between 1 and 1.5 bar as the manual explains.
- When to call a technician
- If the pressure is normal and the code stays. The pump, the pressure sensor or an internal blockage needs checking.
F.28 Ignition failure after several attempts Try it yourself first
- What it means
- The heater isn't getting enough gas, can't light the flame, or loses it after lighting.
- What the source says
- Not enough gas arriving, or a fault in the ignition electrode or the gas valve
- What you can do
- Make sure the gas valve is fully open and the cylinder or meter has gas. Try lighting a cooker burner to see whether gas is arriving at all, then restart the heater.
- When to call a technician
- If gas is arriving and the code stays. The ignition electrode, flame sensor and gas valve are checked by a specialist; don't take apart anything in the gas path yourself.
F.29 Flame went out during operation Try it yourself first
- What it means
- The heater isn't getting enough gas, can't light the flame, or loses it after lighting.
- What the source says
- The flame goes out after lighting and re-ignition then fails
- What you can do
- Make sure the gas valve is fully open and the cylinder or meter has gas. Try lighting a cooker burner to see whether gas is arriving at all, then restart the heater.
- When to call a technician
- If gas is arriving and the code stays. The ignition electrode, flame sensor and gas valve are checked by a specialist; don't take apart anything in the gas path yourself.
F.54 Insufficient gas supply at ignition Try it yourself first
- What it means
- The heater isn't getting enough gas, can't light the flame, or loses it after lighting.
- What the source says
- Appears with F.28 or F.29 and means the gas arriving is less than required
- What you can do
- Make sure the gas valve is fully open and the cylinder or meter has gas. Try lighting a cooker burner to see whether gas is arriving at all, then restart the heater.
- When to call a technician
- If gas is arriving and the code stays. The ignition electrode, flame sensor and gas valve are checked by a specialist; don't take apart anything in the gas path yourself.
F.20 Maximum temperature exceeded inside the appliance Needs a technician
- What it means
- The heater shut itself down to protect against overheating.
- What the source says
- The safety temperature limiter tripped due to overheating
- What you can do
- Let it cool for half an hour, then switch it back on, and make sure the hot water tap delivers water at normal pressure.
- When to call a technician
- If the code keeps appearing. Overheating is usually caused by limescale in the heat exchanger or poor circulation, and needs cleaning or checking.
F.56 Gas mass flow sensor regulation fault Needs a technician
- What it means
- One of the heater's sensors is reading out of range, or its wire is disconnected.
- What the source says
- Sensor readings out of the normal range
- What you can do
- Unplug the heater for a minute, then switch it back on.
- When to call a technician
- If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.
F.75 The appliance doesn't detect a pressure rise when the pump runs Needs a technician
- What it means
- There isn't enough water in the heater, or it isn't circulating properly.
- What the source says
- The pressure sensor or the pump isn't responding
- What you can do
- Open a hot water tap and make sure water arrives at normal pressure. If your heater is a sealed-pressure type, check the pressure gauge and bring it back to between 1 and 1.5 bar as the manual explains.
- When to call a technician
- If the pressure is normal and the code stays. The pump, the pressure sensor or an internal blockage needs checking.
Codes from a single source
We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.
F.60 Gas valve control fault Needs a technician
- What it means
- A fault in the electronic board or the gas valve: an illogical signal or a control that doesn't respond.
- What the source says
- The board isn't controlling the valve properly
- What you can do
- Unplug the heater for a minute, then switch it back on. If the code returns, don't try again.
- When to call a technician
- In almost every case. The board and the gas valve are checked with measuring tools, and only a specialist should work on the gas path.
F.61 Gas valve circuit fault Needs a technician
- What it means
- A fault in the electronic board or the gas valve: an illogical signal or a control that doesn't respond.
- What the source says
- Short or open circuit in the valve connections
- What you can do
- Unplug the heater for a minute, then switch it back on. If the code returns, don't try again.
- When to call a technician
- In almost every case. The board and the gas valve are checked with measuring tools, and only a specialist should work on the gas path.
F.62 Gas valve slow to close after the flame went out Needs a technician
- What it means
- A fault in the electronic board or the gas valve: an illogical signal or a control that doesn't respond.
- What the source says
- The valve doesn't close within the required time
- What you can do
- Unplug the heater for a minute, then switch it back on. If the code returns, don't try again.
- When to call a technician
- In almost every case. The board and the gas valve are checked with measuring tools, and only a specialist should work on the gas path.
F.00 Heating flow temperature sensor fault Needs a technician
- What it means
- One of the heater's sensors is reading out of range, or its wire is disconnected.
- What the source says
- The sensor is reading out of range
- What you can do
- Unplug the heater for a minute, then switch it back on.
- When to call a technician
- If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.
F.01 Return temperature sensor fault Needs a technician
- What it means
- One of the heater's sensors is reading out of range, or its wire is disconnected.
- What the source says
- The sensor is reading out of range
- What you can do
- Unplug the heater for a minute, then switch it back on.
- When to call a technician
- If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.