| Code | Meaning | Who handles it |
|---|
10 | Ventilation or exhaust problem | Try it yourself first |
11 | Ignition failure | Try it yourself first |
12 | Flame went out | Try it yourself first |
14 | Overheating | Stop immediately |
16 | Outlet water temperature too high | Try it yourself first |
19 | Electrical earthing problem | Needs a technician |
25 | Condensate build-up | Try it yourself first |
32 | Outlet water temperature sensor fault | Needs a technician |
33 | Heat exchanger temperature sensor fault | Needs a technician |
34 | Combustion air temperature sensor fault | Try it yourself first |
41 | Freeze protection sensor fault | Needs a technician |
51 | Inlet water temperature sensor fault | Needs a technician |
52 | Gas valve signal fault | Needs a technician |
57 | Burner overheat protection switch open | Needs a technician |
58 | Limescale in the secondary heat exchanger | Needs a technician |
61 | Combustion fan fault | Try it yourself first |
63 | Weak recirculating water flow | Try it yourself first |
65 | Water flow control valve fault | Needs a technician |
70 | Control board fault | Needs a technician |
72 | Flame sensor fault | Needs a technician |
Every code explained
If you smell gas, don't switch on the heater or any electrical switch: close the main valve, open the windows, leave the premises, and call a specialist from outside.
10 Ventilation or exhaust problem Try it yourself first
- What it means
- Air isn't coming in or the exhaust isn't getting out properly.
- What you can do
- Clean the air filter, make sure the flue outlet outside isn't blocked by leaves or nests, and that the drain line isn't backing up.
- When to call a technician
- If the code comes back.
11 Ignition failure Try it yourself first
- What it means
- The heater won't light the flame.
- What you can do
- Make sure the gas valve is open and gas is arriving (a cooker burner works), then switch the heater off and on.
- When to call a technician
- If it keeps happening after checking the gas.
12 Flame went out Try it yourself first
- What it means
- The flame lights, then goes out.
- What you can do
- Make sure the gas is on and steady and the flue outlet isn't blocked, then restart once.
- When to call a technician
- If it keeps happening.
14 Overheating Stop immediately
- What it means
- The heater's temperature went above the safe limit.
- What you can do
- Switch off the heater and let it cool, and make sure the vents aren't blocked. Don't keep restarting it.
- When to call a technician
- Straight away if it keeps happening.
16 Outlet water temperature too high Try it yourself first
- What it means
- The outlet water is hotter than the safe limit.
- What you can do
- Make sure the air intakes and the flue aren't blocked.
- When to call a technician
- The heat exchanger usually needs descaling.
19 Electrical earthing problem Needs a technician
- What it means
- A short circuit or improper earthing in one of the parts.
- What you can do
- Switch off the power to the heater.
- When to call a technician
- Straight away.
32 Outlet water temperature sensor fault Needs a technician
- What it means
- The sensor is giving a wrong reading or its wire is disconnected.
- What you can do
- Switch the heater off and on once.
- When to call a technician
- To check and replace the sensor.
33 Heat exchanger temperature sensor fault Needs a technician
- What it means
- The heat exchanger sensor isn't working.
- What you can do
- Switch the heater off and on once.
- When to call a technician
- To check the sensor.
34 Combustion air temperature sensor fault Try it yourself first
- What it means
- The intake air sensor is giving an abnormal reading, and the air may be blocked.
- What you can do
- Make sure the air intakes and the flue aren't blocked.
- When to call a technician
- If the code comes back.
41 Freeze protection sensor fault Needs a technician
- What it means
- The freeze sensor isn't working.
- What you can do
- If it has an outdoor sensor, make sure it isn't covered.
- When to call a technician
- To check the sensor.
51 Inlet water temperature sensor fault Needs a technician
- What it means
- The cold water inlet sensor isn't working.
- What you can do
- Switch the heater off and on once.
- When to call a technician
- To check the sensor.
52 Gas valve signal fault Needs a technician
- What it means
- The gas modulating valve isn't receiving the correct signal.
- What you can do
- Turn off the power and the gas, wait a moment, then turn them back on.
- When to call a technician
- If the code comes back.
61 Combustion fan fault Try it yourself first
- What it means
- The fan isn't turning properly.
- What you can do
- Turn off the power, and make sure there is no dirt at the air intake.
- When to call a technician
- To check the fan motor.
63 Weak recirculating water flow Try it yourself first
- What it means
- On recirculation systems: water isn't circulating in sufficient quantity.
- What you can do
- Make sure the water valves are open, and clean the water inlet filter.
- When to call a technician
- To adjust the pump and bleed the air.
Codes from a single source
We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.
25 Condensate build-up Try it yourself first
- What it means
- Condensate isn't draining, or its pump isn't working.
- What you can do
- Make sure the condensate drain line isn't blocked or frozen, and that its external pump is plugged in.
- When to call a technician
- If the code comes back.
57 Burner overheat protection switch open Needs a technician
- What it means
- The burner got hotter than it should.
- What you can do
- Switch the heater off and restart it after it cools.
- When to call a technician
- Straight away if it keeps happening.
58 Limescale in the secondary heat exchanger Needs a technician
- What it means
- Limescale has built up in the heat exchanger.
- What you can do
- Nothing safe to do.
- When to call a technician
- The heat exchanger needs descaling.
65 Water flow control valve fault Needs a technician
- What it means
- The valve that controls the amount of water isn't working.
- What you can do
- Nothing safe to do.
- When to call a technician
- Straight away.
70 Control board fault Needs a technician
- What it means
- The electronic board isn't working.
- What you can do
- Switch the heater off and on once.
- When to call a technician
- If the code comes back.
72 Flame sensor fault Needs a technician
- What it means
- The sensor that confirms the flame isn't working properly.
- What you can do
- Nothing safe to do.
- When to call a technician
- To clean or replace the flame sensor.