Immergas boiler error codes

21 codes, each with what it means, what you can safely try yourself, and when to call a technician. Italian boilers common in Romania, Poland and Eastern Europe. The code is a two-digit number such as 01 or 10.

7 of the 21 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
01Ignition failureTry it yourself first
02Shutdown due to overheatingTry it yourself first
03Flue thermostat trippedNeeds a technician
08Maximum number of resets exceededTry it yourself first
10Insufficient water pressureTry it yourself first
15Configuration errorNeeds a technician
16Fan faultTry it yourself first
20Parasitic flameNeeds a technician
24Button panel faultNot a fault
31Lost connection to the remote controlTry it yourself first
37Low supply voltageNot a fault
38Loss of flame signalNot a fault
43Lockout due to loss of flameTry it yourself first
29Flue sensor faultNeeds a technician
06Domestic hot water sensor faultNeeds a technician
23Return sensor faultNeeds a technician
27Insufficient water circulationTry it yourself first
45Large temperature difference between flow and returnTry it yourself first
47Hot flue gas, output reducedNot a fault
60Circulation pump stuckNeeds a technician
61Air in the pumpTry it yourself first

Every code explained

If you smell gas, don't run the boiler or use any electrical switch: close the main valve, open the windows, leave the premises, and call the gas company or emergency services from outside.

01 Ignition failure Try it yourself first

What it means
The boiler didn't light the burner.
What you can do
Make sure the gas valve is open and other gas appliances work, then press Reset.
When to call a technician
If the fault persists after resetting. The Immergas manual recommends contacting an authorised service centre.

02 Shutdown due to overheating Try it yourself first

What it means
The safety thermostat shut down the boiler because the water got too hot.
What you can do
Wait for the boiler to cool, open the radiator valves, then press Reset.
When to call a technician
If the fault persists after resetting. The Immergas manual recommends contacting an authorised service centre.

03 Flue thermostat tripped Needs a technician

What it means
The flue safety thermostat shut down the boiler.
What you can do
Press Reset once.
When to call a technician
If the fault persists after resetting. The Immergas manual recommends contacting an authorised service centre.

08 Maximum number of resets exceeded Try it yourself first

What it means
You can reset only 5 times in a row, after which resetting is blocked for at least an hour.
What you can do
Switch the boiler off and on to restore the attempts, and don't keep pressing Reset.
When to call a technician
A fault that repeats this many times needs a technician.

10 Insufficient water pressure Try it yourself first

What it means
The heating water pressure is low.
What you can do
Look at the boiler's pressure gauge: it should be between 1 and 1.2 bar. If it is lower, top up the water slowly from the filling valve.
When to call a technician
If the pressure keeps dropping.

15 Configuration error Needs a technician

What it means
The boiler isn't configured correctly.
What you can do
Nothing.
When to call a technician
To set the boiler's configuration.

16 Fan fault Try it yourself first

What it means
The flue fan isn't working properly.
What you can do
Press Reset.
When to call a technician
If the fault persists after resetting. The Immergas manual recommends contacting an authorised service centre.

20 Parasitic flame Needs a technician

What it means
The boiler sees a flame at a time when there shouldn't be one.
What you can do
Press Reset.
When to call a technician
If the fault persists after resetting. The Immergas manual recommends contacting an authorised service centre.

24 Button panel fault Not a fault

What it means
A fault in the control panel.
What you can do
When conditions return to normal, the boiler restarts by itself without a reset.
When to call a technician
If it continues.

31 Lost connection to the remote control Try it yourself first

What it means
The boiler can't see the thermostat or the separate controller.
What you can do
Disconnect the power to the boiler, then restore it. If the device is still not detected, the boiler runs on local control.
When to call a technician
If the connection doesn't come back.

37 Low supply voltage Not a fault

What it means
The household supply is below what is required.
What you can do
Wait for the power to return to normal; the boiler restarts by itself.
When to call a technician
If it keeps happening with sound power.

38 Loss of flame signal Not a fault

What it means
The flame went out momentarily.
What you can do
When conditions return to normal, the boiler restarts by itself.
When to call a technician
If it keeps happening.

43 Lockout due to loss of flame Try it yourself first

What it means
The flame went out several times, so the boiler shut itself down.
What you can do
Check the gas, then press Reset. The boiler runs the fan briefly before restarting.
When to call a technician
If the fault persists after resetting. The Immergas manual recommends contacting an authorised service centre.

29 Flue sensor fault Needs a technician

What it means
The flue gas temperature sensor isn't working, and the boiler won't start.
What you can do
Nothing beyond switching the boiler off and on.
When to call a technician
To check the sensor.

Codes from a single source

We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.

06 Domestic hot water sensor fault Needs a technician

What it means
The hot water sensor for the bathroom and kitchen isn't working, so hot water output weakens.
What you can do
Nothing.
When to call a technician
To check the sensor.

23 Return sensor fault Needs a technician

What it means
The return water temperature sensor isn't working.
What you can do
Nothing.
When to call a technician
To check the sensor.

27 Insufficient water circulation Try it yourself first

What it means
The water isn't circulating well, so the boiler overheated.
What you can do
Open the radiator valves and bleed the air out of them, then press Reset.
When to call a technician
If it keeps happening, it's the pump.

45 Large temperature difference between flow and return Try it yourself first

What it means
Poor circulation, the pump setting, or the return sensor.
What you can do
Open the radiator valves and check the pressure.
When to call a technician
If it keeps happening.

47 Hot flue gas, output reduced Not a fault

What it means
The boiler reduced its output to protect itself because the flue gas is hot.
What you can do
Nothing.
When to call a technician
If it happens often.

60 Circulation pump stuck Needs a technician

What it means
The pump isn't turning.
What you can do
Follow the pump-release procedure in your boiler's manual if there is one.
When to call a technician
If it stays stuck.

61 Air in the pump Try it yourself first

What it means
Air trapped in the circulation pump.
What you can do
Bleed the air from the radiators, and check the pressure.
When to call a technician
If it keeps happening.

Sources