A3tali

Home ‹ Water heaters and boilers ‹ Ferroli

Ferroli water heater error codes

11 codes, each with what it means, what you can safely try yourself, and when to call a technician. The codes start with A or F followed by two digits.

1 of the 11 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
A01Ignition failureTry it yourself first
A02False flame signal with the burner offNeeds a technician
A03Water circulation stopped in the systemNeeds a technician
F04Incorrect board parameter settingNeeds a technician
F05Air pressure switch errorNeeds a technician
A06No flame after the ignition phaseNeeds a technician
F10Heating line sensor faultNeeds a technician
F12Hot water sensor faultNeeds a technician
F34Supply voltage below 170 VTry it yourself first
A15Air pressure switch error repeated five times within a dayNeeds a technician
F37Low system water pressureTry it yourself first

Every code explained

If you smell gas, don't switch on the heater or any electrical switch: close the main valve, open the windows, leave the premises, and call a specialist from outside.

A01 Ignition failure Try it yourself first

What it means
The heater isn't getting enough gas, can't light the flame, or loses it after lighting.
What the source says
No gas arriving or an ignition electrode fault
What you can do
Make sure the gas valve is fully open and the cylinder or meter has gas. Try lighting a cooker burner to see whether gas is arriving at all, then restart the heater.
When to call a technician
If gas is arriving and the code stays. The ignition electrode, flame sensor and gas valve are checked by a specialist; don't take apart anything in the gas path yourself.

A02 False flame signal with the burner off Needs a technician

What it means
A fault in the electronic board or the gas valve: an illogical signal or a control that doesn't respond.
What the source says
The board sees a flame signal that isn't real
What you can do
Unplug the heater for a minute, then switch it back on. If the code returns, don't try again.
When to call a technician
In almost every case. The board and the gas valve are checked with measuring tools, and only a specialist should work on the gas path.

A03 Water circulation stopped in the system Needs a technician

What it means
There isn't enough water in the heater, or it isn't circulating properly.
What the source says
The flow switch doesn't detect water movement
What you can do
Open a hot water tap and make sure water arrives at normal pressure. If your heater is a sealed-pressure type, check the pressure gauge and bring it back to between 1 and 1.5 bar as the manual explains.
When to call a technician
If the pressure is normal and the code stays. The pump, the pressure sensor or an internal blockage needs checking.

F04 Incorrect board parameter setting Needs a technician

What it means
A fault in the electronic board or the gas valve: an illogical signal or a control that doesn't respond.
What the source says
Board parameters don't match the appliance's components
What you can do
Unplug the heater for a minute, then switch it back on. If the code returns, don't try again.
When to call a technician
In almost every case. The board and the gas valve are checked with measuring tools, and only a specialist should work on the gas path.

F05 Air pressure switch error Needs a technician

What it means
The heater can't confirm that the exhaust is getting out properly, so it shuts down to protect you from combustion gases.
What the source says
The appliance can't confirm the flue fan is working
What you can do
Don't run the heater while this code is showing. Check the flue from outside: is anything blocking it, or a bird's nest? Make sure the outer cap is in place.
When to call a technician
If the flue is clear and the code stays. The air pressure switch and the fan are checked by a specialist; ignoring this code risks poisoning.

A06 No flame after the ignition phase Needs a technician

What it means
The heater isn't getting enough gas, can't light the flame, or loses it after lighting.
What the source says
The flame lights, then goes out immediately
What you can do
Make sure the gas valve is fully open and the cylinder or meter has gas. Try lighting a cooker burner to see whether gas is arriving at all, then restart the heater.
When to call a technician
If gas is arriving and the code stays. The ignition electrode, flame sensor and gas valve are checked by a specialist; don't take apart anything in the gas path yourself.

F10 Heating line sensor fault Needs a technician

What it means
One of the heater's sensors is reading out of range, or its wire is disconnected.
What the source says
Temperature sensor reading out of range
What you can do
Unplug the heater for a minute, then switch it back on.
When to call a technician
If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.

F34 Supply voltage below 170 V Try it yourself first

What it means
The power reaching the heater isn't at the required level.
What the source says
The voltage reaching the appliance is below the minimum
What you can do
Make sure the breaker hasn't tripped and the household power is normal, and plug the heater straight into a socket without an extension lead.
When to call a technician
If it keeps happening with normal household power.

A15 Air pressure switch error repeated five times within a day Needs a technician

What it means
The heater can't confirm that the exhaust is getting out properly, so it shuts down to protect you from combustion gases.
What the source says
The air pressure switch trips repeatedly
What you can do
Don't run the heater while this code is showing. Check the flue from outside: is anything blocking it, or a bird's nest? Make sure the outer cap is in place.
When to call a technician
If the flue is clear and the code stays. The air pressure switch and the fan are checked by a specialist; ignoring this code risks poisoning.

F37 Low system water pressure Try it yourself first

What it means
There isn't enough water in the heater, or it isn't circulating properly.
What the source says
Restore the pressure to the required range from the filling tap
What you can do
Open a hot water tap and make sure water arrives at normal pressure. If your heater is a sealed-pressure type, check the pressure gauge and bring it back to between 1 and 1.5 bar as the manual explains.
When to call a technician
If the pressure is normal and the code stays. The pump, the pressure sensor or an internal blockage needs checking.
Note
On some models such as Modena, the code means an outdoor sensor fault

Codes from a single source

We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.

F12 Hot water sensor fault Needs a technician

What it means
One of the heater's sensors is reading out of range, or its wire is disconnected.
What the source says
Hot water temperature sensor reading out of range
What you can do
Unplug the heater for a minute, then switch it back on.
When to call a technician
If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.

Sources