Home ‹ Water heaters and boilers ‹ Ferroli
Ferroli water heater error codes
11 codes, each with what it means, what you can safely try yourself, and when to call a technician. The codes start with A or F followed by two digits.
1 of the 11 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.
A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.
Quick table
| Code | Meaning | Who handles it |
|---|
A01 | Ignition failure | Try it yourself first |
A02 | False flame signal with the burner off | Needs a technician |
A03 | Water circulation stopped in the system | Needs a technician |
F04 | Incorrect board parameter setting | Needs a technician |
F05 | Air pressure switch error | Needs a technician |
A06 | No flame after the ignition phase | Needs a technician |
F10 | Heating line sensor fault | Needs a technician |
F12 | Hot water sensor fault | Needs a technician |
F34 | Supply voltage below 170 V | Try it yourself first |
A15 | Air pressure switch error repeated five times within a day | Needs a technician |
F37 | Low system water pressure | Try it yourself first |
Every code explained
If you smell gas, don't switch on the heater or any electrical switch: close the main valve, open the windows, leave the premises, and call a specialist from outside.
A01 Ignition failure Try it yourself first
- What it means
- The heater isn't getting enough gas, can't light the flame, or loses it after lighting.
- What the source says
- No gas arriving or an ignition electrode fault
- What you can do
- Make sure the gas valve is fully open and the cylinder or meter has gas. Try lighting a cooker burner to see whether gas is arriving at all, then restart the heater.
- When to call a technician
- If gas is arriving and the code stays. The ignition electrode, flame sensor and gas valve are checked by a specialist; don't take apart anything in the gas path yourself.
A02 False flame signal with the burner off Needs a technician
- What it means
- A fault in the electronic board or the gas valve: an illogical signal or a control that doesn't respond.
- What the source says
- The board sees a flame signal that isn't real
- What you can do
- Unplug the heater for a minute, then switch it back on. If the code returns, don't try again.
- When to call a technician
- In almost every case. The board and the gas valve are checked with measuring tools, and only a specialist should work on the gas path.
A03 Water circulation stopped in the system Needs a technician
- What it means
- There isn't enough water in the heater, or it isn't circulating properly.
- What the source says
- The flow switch doesn't detect water movement
- What you can do
- Open a hot water tap and make sure water arrives at normal pressure. If your heater is a sealed-pressure type, check the pressure gauge and bring it back to between 1 and 1.5 bar as the manual explains.
- When to call a technician
- If the pressure is normal and the code stays. The pump, the pressure sensor or an internal blockage needs checking.
F04 Incorrect board parameter setting Needs a technician
- What it means
- A fault in the electronic board or the gas valve: an illogical signal or a control that doesn't respond.
- What the source says
- Board parameters don't match the appliance's components
- What you can do
- Unplug the heater for a minute, then switch it back on. If the code returns, don't try again.
- When to call a technician
- In almost every case. The board and the gas valve are checked with measuring tools, and only a specialist should work on the gas path.
F05 Air pressure switch error Needs a technician
- What it means
- The heater can't confirm that the exhaust is getting out properly, so it shuts down to protect you from combustion gases.
- What the source says
- The appliance can't confirm the flue fan is working
- What you can do
- Don't run the heater while this code is showing. Check the flue from outside: is anything blocking it, or a bird's nest? Make sure the outer cap is in place.
- When to call a technician
- If the flue is clear and the code stays. The air pressure switch and the fan are checked by a specialist; ignoring this code risks poisoning.
A06 No flame after the ignition phase Needs a technician
- What it means
- The heater isn't getting enough gas, can't light the flame, or loses it after lighting.
- What the source says
- The flame lights, then goes out immediately
- What you can do
- Make sure the gas valve is fully open and the cylinder or meter has gas. Try lighting a cooker burner to see whether gas is arriving at all, then restart the heater.
- When to call a technician
- If gas is arriving and the code stays. The ignition electrode, flame sensor and gas valve are checked by a specialist; don't take apart anything in the gas path yourself.
F10 Heating line sensor fault Needs a technician
- What it means
- One of the heater's sensors is reading out of range, or its wire is disconnected.
- What the source says
- Temperature sensor reading out of range
- What you can do
- Unplug the heater for a minute, then switch it back on.
- When to call a technician
- If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.
F34 Supply voltage below 170 V Try it yourself first
- What it means
- The power reaching the heater isn't at the required level.
- What the source says
- The voltage reaching the appliance is below the minimum
- What you can do
- Make sure the breaker hasn't tripped and the household power is normal, and plug the heater straight into a socket without an extension lead.
- When to call a technician
- If it keeps happening with normal household power.
A15 Air pressure switch error repeated five times within a day Needs a technician
- What it means
- The heater can't confirm that the exhaust is getting out properly, so it shuts down to protect you from combustion gases.
- What the source says
- The air pressure switch trips repeatedly
- What you can do
- Don't run the heater while this code is showing. Check the flue from outside: is anything blocking it, or a bird's nest? Make sure the outer cap is in place.
- When to call a technician
- If the flue is clear and the code stays. The air pressure switch and the fan are checked by a specialist; ignoring this code risks poisoning.
F37 Low system water pressure Try it yourself first
- What it means
- There isn't enough water in the heater, or it isn't circulating properly.
- What the source says
- Restore the pressure to the required range from the filling tap
- What you can do
- Open a hot water tap and make sure water arrives at normal pressure. If your heater is a sealed-pressure type, check the pressure gauge and bring it back to between 1 and 1.5 bar as the manual explains.
- When to call a technician
- If the pressure is normal and the code stays. The pump, the pressure sensor or an internal blockage needs checking.
- Note
- On some models such as Modena, the code means an outdoor sensor fault
Codes from a single source
We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.
F12 Hot water sensor fault Needs a technician
- What it means
- One of the heater's sensors is reading out of range, or its wire is disconnected.
- What the source says
- Hot water temperature sensor reading out of range
- What you can do
- Unplug the heater for a minute, then switch it back on.
- When to call a technician
- If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.