Buderus boiler error codes
16 codes, each with what it means, what you can safely try yourself, and when to call a technician. German boilers from the Bosch group, common in Poland, the Czech Republic and Romania. The display shows a two-character code such as 6A, sometimes with a three-digit cause number such as 227.
12 of the 16 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.
A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.
Quick table
| Code | Meaning | Who handles it |
|---|
6A | No flame detected | Try it yourself first |
2E | Low water pressure | Try it yourself first |
6C | Flame signal with the burner off | Needs a technician |
3C | Fan fault | Needs a technician |
LoPr | Low water pressure (newer models) | Try it yourself first |
2980 | Safety lockout after too many reset attempts | Needs a technician |
4C | Safety temperature limiter tripped | Needs a technician |
2P | Temperature rising too fast | Needs a technician |
2Y | The pump isn't building pressure | Needs a technician |
3A | Air pressure switch opened during operation | Needs a technician |
1L | Flue gases escaping in the combustion chamber | Needs a technician |
4U | Flow sensor short circuit | Needs a technician |
4Y | Flow sensor open circuit | Needs a technician |
3F | Safety stop after 24 hours of operation | Not a fault |
0A | Waiting before re-ignition | Not a fault |
0H | Ready, no heat demand | Not a fault |
Every code explained
If you smell gas, don't run the boiler or use any electrical switch: close the main valve, open the windows, leave the premises, and call the gas company or emergency services from outside.
6A No flame detected Try it yourself first
- What it means
- The boiler tried to light 4 times and no flame appeared: gas cut off, the ignition electrode, the flue, or the condensate drain.
- What you can do
- Make sure the gas valve is open, other gas appliances work, and the condensate pipe isn't frozen. Then switch the boiler off and on, or press the reset button.
- When to call a technician
- If the code returns after a reset. Give the technician the code and the cause number.
2E Low water pressure Try it yourself first
- What it means
- The heating water pressure is lower than required, or the pressure sensor is faulty.
- What you can do
- Look at the pressure gauge: if it is below 1 bar, slowly open the filling valve under the boiler until it reaches 1 to 1.5 bar, then close it firmly.
- When to call a technician
- If the pressure keeps dropping, or the code stays with sound pressure.
6C Flame signal with the burner off Needs a technician
- What it means
- The boiler sees a flame before ignition or after the gas is shut off: the flame detection electrode or the gas valve.
- What you can do
- Switch the boiler off and on, or press the reset button.
- When to call a technician
- Straight away.
3C Fan fault Needs a technician
- What it means
- The fan isn't working or its signal is lost.
- What you can do
- Switch the boiler off and on, or press the reset button.
- When to call a technician
- If the code returns after a reset. Give the technician the code and the cause number.
Codes from a single source
We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.
LoPr Low water pressure (newer models) Try it yourself first
- What it means
- On GB172i.2: the heating pressure is low. If LoPr alternates with the pressure reading, the pressure is below 0.3 bar and the boiler has stopped.
- What you can do
- With the boiler cold, top up the water to 1 to 2 bar, and don't exceed 3 bar.
- When to call a technician
- If the pressure keeps dropping.
2980 Safety lockout after too many reset attempts Needs a technician
- What it means
- The boiler locked out for safety reasons after repeated resets.
- What you can do
- Don't try resetting again.
- When to call a technician
- Only the technician or customer service can release the lock after fixing the cause.
4C Safety temperature limiter tripped Needs a technician
- What it means
- The water or the heat exchanger got too hot: low pressure, air, or the pump.
- What you can do
- Make sure the pressure is above 1 bar and the radiator valves are open, then switch the boiler off and on, or press the reset button.
- When to call a technician
- If the code returns after a reset. Give the technician the code and the cause number.
2P Temperature rising too fast Needs a technician
- What it means
- The heating water is heating up too fast: the pump or closed valves.
- What you can do
- Check the pressure and that the radiator valves are open, then switch the boiler off and on, or press the reset button.
- When to call a technician
- If the code returns after a reset. Give the technician the code and the cause number.
2Y The pump isn't building pressure Needs a technician
- What it means
- The heating pump isn't pushing the water.
- What you can do
- Check the pressure and that the service valves are open.
- When to call a technician
- To bleed the air or check the pump.
3A Air pressure switch opened during operation Needs a technician
- What it means
- A problem with the fan or the flue pipe.
- What you can do
- Switch the boiler off and on, or press the reset button.
- When to call a technician
- If the code returns after a reset. Give the technician the code and the cause number.
1L Flue gases escaping in the combustion chamber Needs a technician
- What it means
- The heat exchanger needs cleaning.
- What you can do
- Switch off the boiler.
- When to call a technician
- To clean the heat exchanger.
4U Flow sensor short circuit Needs a technician
- What it means
- The flow temperature sensor or its wire is shorted.
- What you can do
- Switch the boiler off and on, or press the reset button.
- When to call a technician
- To replace the sensor.
4Y Flow sensor open circuit Needs a technician
- What it means
- The flow temperature sensor or its wire is broken.
- What you can do
- Switch the boiler off and on, or press the reset button.
- When to call a technician
- To replace the sensor.
3F Safety stop after 24 hours of operation Not a fault
- What it means
- The burner and fan ran for 24 hours continuously, so the boiler stopped briefly.
- What you can do
- Nothing. It restarts by itself.
- When to call a technician
- Not needed.
0A Waiting before re-ignition Not a fault
- What it means
- Status code: the boiler is waiting for the minimum interval before lighting the burner again.
- What you can do
- Nothing.
- When to call a technician
- Not needed.
0H Ready, no heat demand Not a fault
- What it means
- Status code: the boiler is ready and nobody is asking for heating or hot water.
- What you can do
- Nothing.
- When to call a technician
- Not needed.