Bosch water heater error codes
9 codes, each with what it means, what you can safely try yourself, and when to call a technician. The codes are a letter and a number (such as EA and E9) for tankless water heaters.
5 of the 9 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.
A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.
Quick table
| Code | Meaning | Who handles it |
|---|
EA | No flame detected during the safety time | Try it yourself first |
E2 | Inlet water temperature sensor fault | Needs a technician |
E9 | Temperature limiter opened due to overheating | Needs a technician |
C6 | Fan speed below the required level | Needs a technician |
A7 | The outlet water temperature sensor isn't reading the expected temperature | Try it yourself first |
EC | Gas valve circuit fault | Stop immediately |
C7 | The fan isn't reaching the required speed | Needs a technician |
A0 | Ignition failure (Greentherm) | Try it yourself first |
BB | Burner lockout after repeated failure (Greentherm) | Needs a technician |
Every code explained
If you smell gas, don't switch on the heater or any electrical switch: close the main valve, open the windows, leave the premises, and call a specialist from outside.
EA No flame detected during the safety time Try it yourself first
- What it means
- The heater isn't getting enough gas, can't light the flame, or loses it after lighting.
- What the source says
- Gas isn't arriving or an ignition fault
- What you can do
- Make sure the gas valve is fully open and the cylinder or meter has gas. Try lighting a cooker burner to see whether gas is arriving at all, then restart the heater.
- When to call a technician
- If gas is arriving and the code stays. The ignition electrode, flame sensor and gas valve are checked by a specialist; don't take apart anything in the gas path yourself.
E2 Inlet water temperature sensor fault Needs a technician
- What it means
- One of the heater's sensors is reading out of range, or its wire is disconnected.
- What the source says
- The sensor is reading out of range
- What you can do
- Unplug the heater for a minute, then switch it back on.
- When to call a technician
- If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.
E9 Temperature limiter opened due to overheating Needs a technician
- What it means
- The heater shut itself down to protect against overheating.
- What the source says
- The protection opened, usually because of limescale in the heat exchanger
- What you can do
- Let it cool for half an hour, then switch it back on, and make sure the hot water tap delivers water at normal pressure.
- When to call a technician
- If the code keeps appearing. Overheating is usually caused by limescale in the heat exchanger or poor circulation, and needs cleaning or checking.
C6 Fan speed below the required level Needs a technician
- What it means
- The heater can't confirm that the exhaust is getting out properly, so it shuts down to protect you from combustion gases.
- What the source says
- The fan isn't reaching the required speed
- What you can do
- Don't run the heater while this code is showing. Check the flue from outside: is anything blocking it, or a bird's nest? Make sure the outer cap is in place.
- When to call a technician
- If the flue is clear and the code stays. The air pressure switch and the fan are checked by a specialist; ignoring this code risks poisoning.
Codes from a single source
We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.
A7 The outlet water temperature sensor isn't reading the expected temperature Try it yourself first
- What it means
- The sensor on the hot water pipe isn't seeing the temperature the heater expects. It appears blinking as a status message.
- What you can do
- Make sure the sensor is firmly attached to the hot water pipe.
- When to call a technician
- If the code stays with the sensor attached.
EC Gas valve circuit fault Stop immediately
- What it means
- The gas valve isn't closing as it should.
- What you can do
- Close the gas valve to the heater and don't run it. If you smell gas, open the windows and don't use any switch.
- When to call a technician
- Straight away.
C7 The fan isn't reaching the required speed Needs a technician
- What it means
- The exhaust fan isn't turning at the required speed or its signal is lost.
- What you can do
- Disconnect the power and make sure the flue outlet outside the house isn't blocked, then restart.
- When to call a technician
- If the code comes back. The fan may need replacing.
A0 Ignition failure (Greentherm) Try it yourself first
- What it means
- No stable flame was detected after the ignition attempts.
- What you can do
- Make sure gas is arriving and other gas appliances work, and that the water flow is sufficient. Disconnect the power for 30 seconds, then restart.
- When to call a technician
- If it keeps happening.
BB Burner lockout after repeated failure (Greentherm) Needs a technician
- What it means
- The heater locked the burner after several failed ignition attempts, usually after code A0.
- What you can do
- Fix the cause of the ignition failure first, then hold the power button for 3 to 5 seconds.
- When to call a technician
- If A0 or BB comes straight back.