A3tali

Home ‹ Water heaters and boilers ‹ Bosch

Bosch water heater error codes

9 codes, each with what it means, what you can safely try yourself, and when to call a technician. The codes are a letter and a number (such as EA and E9) for tankless water heaters.

5 of the 9 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
EANo flame detected during the safety timeTry it yourself first
E2Inlet water temperature sensor faultNeeds a technician
E9Temperature limiter opened due to overheatingNeeds a technician
C6Fan speed below the required levelNeeds a technician
A7The outlet water temperature sensor isn't reading the expected temperatureTry it yourself first
ECGas valve circuit faultStop immediately
C7The fan isn't reaching the required speedNeeds a technician
A0Ignition failure (Greentherm)Try it yourself first
BBBurner lockout after repeated failure (Greentherm)Needs a technician

Every code explained

If you smell gas, don't switch on the heater or any electrical switch: close the main valve, open the windows, leave the premises, and call a specialist from outside.

EA No flame detected during the safety time Try it yourself first

What it means
The heater isn't getting enough gas, can't light the flame, or loses it after lighting.
What the source says
Gas isn't arriving or an ignition fault
What you can do
Make sure the gas valve is fully open and the cylinder or meter has gas. Try lighting a cooker burner to see whether gas is arriving at all, then restart the heater.
When to call a technician
If gas is arriving and the code stays. The ignition electrode, flame sensor and gas valve are checked by a specialist; don't take apart anything in the gas path yourself.

E2 Inlet water temperature sensor fault Needs a technician

What it means
One of the heater's sensors is reading out of range, or its wire is disconnected.
What the source says
The sensor is reading out of range
What you can do
Unplug the heater for a minute, then switch it back on.
When to call a technician
If the code comes back. The sensor is measured and replaced; it is usually a small, inexpensive part.

E9 Temperature limiter opened due to overheating Needs a technician

What it means
The heater shut itself down to protect against overheating.
What the source says
The protection opened, usually because of limescale in the heat exchanger
What you can do
Let it cool for half an hour, then switch it back on, and make sure the hot water tap delivers water at normal pressure.
When to call a technician
If the code keeps appearing. Overheating is usually caused by limescale in the heat exchanger or poor circulation, and needs cleaning or checking.

C6 Fan speed below the required level Needs a technician

What it means
The heater can't confirm that the exhaust is getting out properly, so it shuts down to protect you from combustion gases.
What the source says
The fan isn't reaching the required speed
What you can do
Don't run the heater while this code is showing. Check the flue from outside: is anything blocking it, or a bird's nest? Make sure the outer cap is in place.
When to call a technician
If the flue is clear and the code stays. The air pressure switch and the fan are checked by a specialist; ignoring this code risks poisoning.

Codes from a single source

We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.

A7 The outlet water temperature sensor isn't reading the expected temperature Try it yourself first

What it means
The sensor on the hot water pipe isn't seeing the temperature the heater expects. It appears blinking as a status message.
What you can do
Make sure the sensor is firmly attached to the hot water pipe.
When to call a technician
If the code stays with the sensor attached.

EC Gas valve circuit fault Stop immediately

What it means
The gas valve isn't closing as it should.
What you can do
Close the gas valve to the heater and don't run it. If you smell gas, open the windows and don't use any switch.
When to call a technician
Straight away.

C7 The fan isn't reaching the required speed Needs a technician

What it means
The exhaust fan isn't turning at the required speed or its signal is lost.
What you can do
Disconnect the power and make sure the flue outlet outside the house isn't blocked, then restart.
When to call a technician
If the code comes back. The fan may need replacing.

A0 Ignition failure (Greentherm) Try it yourself first

What it means
No stable flame was detected after the ignition attempts.
What you can do
Make sure gas is arriving and other gas appliances work, and that the water flow is sufficient. Disconnect the power for 30 seconds, then restart.
When to call a technician
If it keeps happening.

BB Burner lockout after repeated failure (Greentherm) Needs a technician

What it means
The heater locked the burner after several failed ignition attempts, usually after code A0.
What you can do
Fix the cause of the ignition failure first, then hold the power button for 3 to 5 seconds.
When to call a technician
If A0 or BB comes straight back.

Sources