FG Wilson generator error codes

24 codes, each with what it means, what you can safely try yourself, and when to call a technician.

14 of the 24 entries on this page come from a single unconfirmed source, so they are listed separately at the end of the page.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
SPN 38-1External tank fuel level low, protective shutdownTry it yourself first
SPN 82-1Starting air pressure low, protective shutdownNeeds a technician
SPN 95-15Fuel filter nearly blocked, high differential pressure (warning)Try it yourself first
SPN 96-1Fuel level low, protective shutdownTry it yourself first
SPN 98-1Engine oil level low, protective shutdownNeeds a technician
SPN 107-15Air filter nearly blocked and needs servicing (warning)Try it yourself first
SPN 110-0Coolant temperature above the limit, protective shutdownNeeds a technician
SPN 110-15Coolant temperature high (warning)Try it yourself first
SPN 111-1Coolant level low, protective shutdownTry it yourself first
SPN 137-1Fire suppression system pressure low, protective shutdownNeeds a technician
SPN 100-1Engine oil pressure low, protective shutdownTry it yourself first
SPN 100-17Engine oil pressure low (warning)Try it yourself first
SPN 168-15Battery voltage high (warning)Needs a technician
SPN 168-17Battery voltage low (warning)Try it yourself first
SPN 190-0Engine overspeed, protective shutdownStop immediately
SPN 190-1Engine underspeed, protective shutdownTry it yourself first
SPN 190-2Engine speed sensor signal intermittent or lostNeeds a technician
SPN 1664-31The engine failed to startTry it yourself first
SPN 2436-0Frequency high, protective shutdownNeeds a technician
SPN 2436-1Frequency low, protective shutdownTry it yourself first
SPN 2440-0Generator voltage high, protective shutdownNeeds a technician
SPN 2440-1Generator voltage low, protective shutdownNeeds a technician
SPN 2448-0Generator overcurrent, protective shutdownTry it yourself first
SPN 2452-1Reverse power, protective shutdownNeeds a technician

Every code explained

Don't open the radiator cap while the engine is hot, as pressurised steam burns; don't go near a running generator in loose clothing, and keep children away from it.

SPN 38-1 External tank fuel level low, protective shutdown Try it yourself first

What it means
Fuel isn't reaching the engine or is about to run out.
What the source says
External fuel tank nearly empty
What you can do
Check the fuel tank first, then the fuel tap and filter. After refuelling, bleed the air from the fuel system as the manual explains.
When to call a technician
If the tank is full and the alarm stays. The fuel pump or the level sensor is checked.

SPN 82-1 Starting air pressure low, protective shutdown Needs a technician

What it means
An internal generator fault that needs checking.
What the source says
Low starting air on air-start models
What you can do
Press Stop, then Reset on the controller once the cause has cleared, then restart.
When to call a technician
If the code returns after restarting. Give the technician the code and model number exactly.

SPN 95-15 Fuel filter nearly blocked, high differential pressure (warning) Try it yourself first

What it means
Fuel isn't reaching the engine or is about to run out.
What the source says
The fuel filter is dirty and needs replacing
What you can do
Check the fuel tank first, then the fuel tap and filter. After refuelling, bleed the air from the fuel system as the manual explains.
When to call a technician
If the tank is full and the alarm stays. The fuel pump or the level sensor is checked.

SPN 96-1 Fuel level low, protective shutdown Try it yourself first

What it means
Fuel isn't reaching the engine or is about to run out.
What the source says
The fuel tank is nearly empty
What you can do
Check the fuel tank first, then the fuel tap and filter. After refuelling, bleed the air from the fuel system as the manual explains.
When to call a technician
If the tank is full and the alarm stays. The fuel pump or the level sensor is checked.

SPN 98-1 Engine oil level low, protective shutdown Needs a technician

What it means
Engine oil pressure is below the safe limit, and running with it destroys the engine.
What the source says
The oil is low or leaking
What you can do
Stop the generator immediately. Check the oil level with the dipstick when the engine is cold, add the right type if it is low, and look for a leak under the engine.
When to call a technician
If the level is normal and the alarm stays. The pressure sensor or the oil pump is checked.

SPN 107-15 Air filter nearly blocked and needs servicing (warning) Try it yourself first

What it means
A reminder that scheduled maintenance is due after a set number of running hours, not a fault.
What the source says
The air filter is dirty
What you can do
Carry out the scheduled maintenance of oil and filters, then reset the reminder from the controller.
When to call a technician
If the reminder appears much earlier than due.

SPN 110-0 Coolant temperature above the limit, protective shutdown Needs a technician

What it means
The engine temperature exceeded the safe limit.
What the source says
The engine got hotter than the safe limit
What you can do
Stop the generator and let it cool; don't open the radiator cap while it is hot. Once cool: check the coolant level, clean the dust off the radiator fins, and make sure the load isn't greater than the generator's capacity.
When to call a technician
If it keeps happening with full coolant and a clean radiator. The thermostat, water pump or temperature sensor is checked.

SPN 110-15 Coolant temperature high (warning) Try it yourself first

What it means
The engine temperature exceeded the safe limit.
What the source says
The load is heavy or the radiator is dirty
What you can do
Stop the generator and let it cool; don't open the radiator cap while it is hot. Once cool: check the coolant level, clean the dust off the radiator fins, and make sure the load isn't greater than the generator's capacity.
When to call a technician
If it keeps happening with full coolant and a clean radiator. The thermostat, water pump or temperature sensor is checked.

SPN 111-1 Coolant level low, protective shutdown Try it yourself first

What it means
The engine temperature exceeded the safe limit.
What the source says
Low radiator water or a leak in the circuit
What you can do
Stop the generator and let it cool; don't open the radiator cap while it is hot. Once cool: check the coolant level, clean the dust off the radiator fins, and make sure the load isn't greater than the generator's capacity.
When to call a technician
If it keeps happening with full coolant and a clean radiator. The thermostat, water pump or temperature sensor is checked.

SPN 137-1 Fire suppression system pressure low, protective shutdown Needs a technician

What it means
An internal generator fault that needs checking.
What the source says
A fault in the attached fire suppression system
What you can do
Press Stop, then Reset on the controller once the cause has cleared, then restart.
When to call a technician
If the code returns after restarting. Give the technician the code and model number exactly.

Codes from a single source

We found the following in only one source, with no second source confirming it, so it is kept here apart from the confirmed explanations above. Treat it as a first hint and check it against your appliance's manual.

SPN 100-1 Engine oil pressure low, protective shutdown Try it yourself first

What it means
The oil pressure dropped below the safe limit, so the controller stopped the generator.
What you can do
Switch off the generator and wait a little, then check the oil level with the dipstick and top up if it is low. Don't run it if the oil is low.
When to call a technician
If the oil is full and the shutdown keeps happening.

SPN 100-17 Engine oil pressure low (warning) Try it yourself first

What it means
The oil pressure is lower than usual but hasn't reached the shutdown limit.
What you can do
Check the oil level at the next opportunity and top up if needed.
When to call a technician
If the warning keeps appearing with the oil full.

SPN 168-15 Battery voltage high (warning) Needs a technician

What it means
The starting battery voltage is higher than usual, usually from the charger.
What you can do
Check the battery charger setting.
When to call a technician
If it keeps happening. The charger or the charge regulator needs checking.

SPN 168-17 Battery voltage low (warning) Try it yourself first

What it means
The starting battery is weak and the generator may not start.
What you can do
Make sure the battery terminals are clean and tight, and the battery charger is working.
When to call a technician
If it stays weak after charging.

SPN 190-0 Engine overspeed, protective shutdown Stop immediately

What it means
The engine turned faster than the safe limit.
What you can do
Don't restart before it is checked.
When to call a technician
Straight away. The technician checks the fuel system and the governor.

SPN 190-1 Engine underspeed, protective shutdown Try it yourself first

What it means
The engine didn't reach its required speed, usually because of a heavy load or a fuel shortage.
What you can do
Check the fuel and the filter, reduce the load, then restart.
When to call a technician
If it keeps happening.

SPN 190-2 Engine speed sensor signal intermittent or lost Needs a technician

What it means
The controller isn't reading the engine speed correctly.
What you can do
Switch the generator off, then restart it.
When to call a technician
If the code comes back. The technician checks the sensor and its wire.

SPN 1664-31 The engine failed to start Try it yourself first

What it means
The generator tried to start several times and didn't run.
What you can do
Check the fuel and the battery, and make sure the emergency stop isn't pressed.
When to call a technician
If all of that is fine.

SPN 2436-0 Frequency high, protective shutdown Needs a technician

What it means
The generator's frequency is higher than allowed.
What you can do
Disconnect the loads and don't restart before it is checked.
When to call a technician
Straight away.

SPN 2436-1 Frequency low, protective shutdown Try it yourself first

What it means
The generator's frequency is lower than allowed, usually because of an overload.
What you can do
Reduce the loads, check the fuel, then restart.
When to call a technician
If it keeps happening with light loads.

SPN 2440-0 Generator voltage high, protective shutdown Needs a technician

What it means
The generator's output voltage is higher than allowed.
What you can do
Disconnect the loads and don't restart before it is checked.
When to call a technician
Straight away. The technician checks the voltage regulator (AVR).

SPN 2440-1 Generator voltage low, protective shutdown Needs a technician

What it means
The generator's output voltage is lower than allowed.
What you can do
Reduce the loads, then restart.
When to call a technician
If it keeps happening. The technician checks the voltage regulator (AVR).

SPN 2448-0 Generator overcurrent, protective shutdown Try it yourself first

What it means
The loads drew more current than the generator's capacity.
What you can do
Disconnect the loads, restart, then add them gradually.
When to call a technician
If it keeps happening with loads within the generator's capacity.

SPN 2452-1 Reverse power, protective shutdown Needs a technician

What it means
Power is flowing back into the generator instead of out of it, usually in synchronised systems.
What you can do
Don't restart before it is checked.
When to call a technician
Straight away.