A3tali

Home ‹ Dehumidifiers ‹ Midea

Midea dehumidifier error codes

6 codes, each with what it means, what you can safely try yourself, and when to call a technician. From its official manual.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
ESHumidity sensor faultNeeds a technician
ASTemperature sensor faultNeeds a technician
P2Water tank full or not fitted properlyTry it yourself first
ECSealed refrigeration circuit faultNeeds a technician
EbElectronic board faultNeeds a technician
E3Protection: room temperature outside the operating rangeTry it yourself first

Every code explained

Don't turn the unit on its side or upside down; move it upright and wait an hour after moving before switching it on, so the compressor oil settles.

ES Humidity sensor fault Needs a technician

What it means
One of the unit's sensors is giving a reading out of range.
What the source says
A damaged sensor
What you can do
Unplug the unit for half a minute, then plug it back in.
When to call a technician
If the code comes back. The sensor is measured and replaced.

AS Temperature sensor fault Needs a technician

What it means
One of the unit's sensors is giving a reading out of range.
What the source says
A damaged sensor
What you can do
Unplug the unit for half a minute, then plug it back in.
When to call a technician
If the code comes back. The sensor is measured and replaced.

P2 Water tank full or not fitted properly Try it yourself first

What it means
The unit isn't getting rid of the collected water: the tank isn't fitted or is full, or the drain pump isn't emptying.
What the source says
Empty the tank and refit it until it sits in place
What you can do
Empty the tank and refit it until it sits in place, and check the drain hose: no kinks, no blockage, and not raised higher than the manual allows.
When to call a technician
If the code stays with the tank fitted and the hose sound. The float or the pump is checked.

EC Sealed refrigeration circuit fault Needs a technician

What it means
A fault in the sealed refrigeration circuit: a refrigerant leak or the compressor.
What the source says
A refrigerant leak or a failed compressor
What you can do
Nothing on your side except restarting once.
When to call a technician
In every case. The sealed refrigeration circuit is a specialist's job only.

Eb Electronic board fault Needs a technician

What it means
A fault in the electronic control board.
What the source says
The control board has failed
What you can do
Unplug the unit for half a minute, then plug it back in.
When to call a technician
If the code comes back.

E3 Protection: room temperature outside the operating range Try it yourself first

What it means
The room temperature is outside the unit's operating range, so it shut itself down for protection.
What the source says
Run the unit in a room between 5 and 35 °C
What you can do
Run the unit in a room within its manual's range (usually between 5 and 35 °C), and switch it off for two hours if the room is very hot.
When to call a technician
If the code appears in a room at normal temperature. The temperature sensor is checked.

Sources