A3tali

Home ‹ Dehumidifiers ‹ Honeywell

Honeywell dehumidifier error codes

5 codes, each with what it means, what you can safely try yourself, and when to call a technician. For the common TP models.

All the codes on this page come from a single unofficial source, and we have not yet found a second one confirming them. Treat them as a first hint and check them against your appliance's manual before any repair.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
E1Temperature sensor faultNeeds a technician
E2Temperature sensor faultNeeds a technician
E3Refrigeration circuit protection: the room temperature exceeded the allowed limitTry it yourself first
P1The water tank isn't fitted in its correct placeTry it yourself first
EHThe continuous drain outlet gasket is missingTry it yourself first

Every code explained

Don't turn the unit on its side or upside down; move it upright and wait an hour after moving before switching it on, so the compressor oil settles.

E1 Temperature sensor fault Needs a technician

What it means
One of the unit's sensors is giving a reading out of range.
What the source says
A damaged sensor
What you can do
Unplug the unit for half a minute, then plug it back in.
When to call a technician
If the code comes back. The sensor is measured and replaced.

E2 Temperature sensor fault Needs a technician

What it means
One of the unit's sensors is giving a reading out of range.
What the source says
A damaged sensor
What you can do
Unplug the unit for half a minute, then plug it back in.
When to call a technician
If the code comes back. The sensor is measured and replaced.

E3 Refrigeration circuit protection: the room temperature exceeded the allowed limit Try it yourself first

What it means
The room temperature is outside the unit's operating range, so it shut itself down for protection.
What the source says
Switch off the unit and move it to a cooler room for two hours
What you can do
Run the unit in a room within its manual's range (usually between 5 and 35 °C), and switch it off for two hours if the room is very hot.
When to call a technician
If the code appears in a room at normal temperature. The temperature sensor is checked.

P1 The water tank isn't fitted in its correct place Try it yourself first

What it means
The unit isn't getting rid of the collected water: the tank isn't fitted or is full, or the drain pump isn't emptying.
What the source says
Take out the tank and refit it until it sits in place
What you can do
Empty the tank and refit it until it sits in place, and check the drain hose: no kinks, no blockage, and not raised higher than the manual allows.
When to call a technician
If the code stays with the tank fitted and the hose sound. The float or the pump is checked.
Note
For TP models with a drain pump

EH The continuous drain outlet gasket is missing Try it yourself first

What it means
The unit isn't getting rid of the collected water: the tank isn't fitted or is full, or the drain pump isn't emptying.
What the source says
Look for it in the packaging box and fit it before connecting the hose
What you can do
Empty the tank and refit it until it sits in place, and check the drain hose: no kinks, no blockage, and not raised higher than the manual allows.
When to call a technician
If the code stays with the tank fitted and the hose sound. The float or the pump is checked.