48 codes, each with what it means, what you can safely try yourself, and when to call a technician. Four-digit codes for City Multi systems.

All the codes on this page come from a single unofficial source, and we have not yet found a second one confirming them. Treat them as a first hint and check them against your appliance's manual before any repair.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
0403Serial communication error between the outdoor unit's boardsNeeds a technician
1102Discharge temperature fault from poor cooling or low refrigerantNeeds a technician
1301Low pressure fault; possible refrigerant leakNeeds a technician
1302High pressure fault from a blocked condenser or a fan faultTry it yourself first
1500Refrigerant overchargeNeeds a technician
2500Drain sensor flooded because of a pump problemTry it yourself first
2502Drain pump fault and high water levelNeeds a technician
2503Drain sensor open or shortedNeeds a technician
2600Water leaking from the humidifier pipesNeeds a technician
4102Mains phase lossNeeds a technician
4106Transmission line power fault from incorrect M-Net wiringNeeds a technician
4115Power signal synchronisation error from a blown fuseNeeds a technician
4116Fan motor speed or connection errorNeeds a technician
4220Abnormal line voltageNeeds a technician
4225Low line voltage from an incorrect supplyNeeds a technician
4230Heat sink overheating protectionTry it yourself first
4240Overload protectionNeeds a technician
4250Overcurrent protection from the compressor or inverterNeeds a technician
4255Outdoor fan errorNeeds a technician
4260Heat sink overheating protection at start-upTry it yourself first
5101Temperature sensor faultNeeds a technician
5102Return air sensor faultNeeds a technician
5110Outdoor inverter heat sink sensor errorNeeds a technician
5201PS1 pressure sensor faultNeeds a technician
5301Current sensor faultNeeds a technician
5701Float connector looseNeeds a technician
6201Remote control problemNeeds a technician
6600Duplicate address on the M-Net networkNeeds a technician
6601Polarity error; no voltage on the M-Net lineNeeds a technician
6602Hardware error in the transmission processor from interferenceNeeds a technician
6603Transmission line busyNeeds a technician
6606Communication fault from a poor M-Net terminal connectionNeeds a technician
6607No acknowledgement signalNeeds a technician
6608No responseNeeds a technician
6831MA controller signal reception errorNeeds a technician
6832MA controller communication fault from a mismatched cableNeeds a technician
6833MA controller communication fault from incorrect wiringNeeds a technician
6834MA controller signal reception errorNeeds a technician
7100Total capacity exceeds what the outdoor unit allowsNeeds a technician
7101Capacity code setting errorNeeds a technician
7102Incorrect number of connected unitsNeeds a technician
7105Address setting errorNeeds a technician
7106Attribute setting errorNeeds a technician
7110Signal transmission error from a loose connectionNeeds a technician
7111Remote control sensor faultNeeds a technician
7113Function setting errorNeeds a technician
7117Model setting errorNeeds a technician
7130Incompatible unit combinationNeeds a technician

Every code explained

These systems run at high pressures on three-phase power. Nothing in them is opened without a qualified technician.

0403 Serial communication error between the outdoor unit's boards Needs a technician

What it means
The indoor and outdoor units (or two boards inside the unit) exchange a signal over a wire, and that signal has been lost.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Make sure the outdoor unit's breaker is on. Note whether the code started after installation, relocation or a power cut.
When to call a technician
If the code comes back after restarting. Checking the cable and terminals is done with the power on, which is a technician's job.
Note
Numeric codes for commercial City Multi systems

1102 Discharge temperature fault from poor cooling or low refrigerant Needs a technician

What it means
There is less refrigerant in the system than needed, usually because of a leak.
What you can do
Clean the filter and confirm that cooling really is weak. There is nothing else to do on your side.
When to call a technician
In almost every case. Ask the technician to find and repair the leak before recharging; recharging alone is only a temporary fix.

1301 Low pressure fault; possible refrigerant leak Needs a technician

What it means
There is less refrigerant in the system than needed, usually because of a leak.
What you can do
Clean the filter and confirm that cooling really is weak. There is nothing else to do on your side.
When to call a technician
In almost every case. Ask the technician to find and repair the leak before recharging; recharging alone is only a temporary fix.

1302 High pressure fault from a blocked condenser or a fan fault Try it yourself first

What it means
The fan is not turning, or it turns but the unit does not receive its rotation signal.
What you can do
Turn the unit off and check whether anything is blocking the fan: built-up dirt, a leaf or a foreign object. Never put your hand in while the power is on.
When to call a technician
If the fan turns freely but does not run. The motor, its capacitor or the board needs testing.

1500 Refrigerant overcharge Needs a technician

What it means
There is less refrigerant in the system than needed, usually because of a leak.
What you can do
Clean the filter and confirm that cooling really is weak. There is nothing else to do on your side.
When to call a technician
In almost every case. Ask the technician to find and repair the leak before recharging; recharging alone is only a temporary fix.

2500 Drain sensor flooded because of a pump problem Try it yourself first

What it means
Condensate water isn't draining from the unit as it should, so the unit stopped itself to keep water from dripping into the room.
What you can do
Make sure the drain hose isn't kinked or blocked at its outer end, and that the indoor unit is level.
When to call a technician
If the hose looks fine from outside. An internal blockage or pump fault means opening the unit.

2502 Drain pump fault and high water level Needs a technician

What it means
Condensate water isn't draining from the unit as it should, so the unit stopped itself to keep water from dripping into the room.
What you can do
Make sure the drain hose isn't kinked or blocked at its outer end, and that the indoor unit is level.
When to call a technician
If the hose looks fine from outside. An internal blockage or pump fault means opening the unit.

2503 Drain sensor open or shorted Needs a technician

What it means
Condensate water isn't draining from the unit as it should, so the unit stopped itself to keep water from dripping into the room.
What you can do
Make sure the drain hose isn't kinked or blocked at its outer end, and that the indoor unit is level.
When to call a technician
If the hose looks fine from outside. An internal blockage or pump fault means opening the unit.

2600 Water leaking from the humidifier pipes Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

4102 Mains phase loss Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

4106 Transmission line power fault from incorrect M-Net wiring Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

4115 Power signal synchronisation error from a blown fuse Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

4116 Fan motor speed or connection error Needs a technician

What it means
The fan is not turning, or it turns but the unit does not receive its rotation signal.
What you can do
Turn the unit off and check whether anything is blocking the fan: built-up dirt, a leaf or a foreign object. Never put your hand in while the power is on.
When to call a technician
If the fan turns freely but does not run. The motor, its capacitor or the board needs testing.

4220 Abnormal line voltage Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

4225 Low line voltage from an incorrect supply Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

4230 Heat sink overheating protection Try it yourself first

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

4240 Overload protection Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

4250 Overcurrent protection from the compressor or inverter Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

4255 Outdoor fan error Needs a technician

What it means
The fan is not turning, or it turns but the unit does not receive its rotation signal.
What you can do
Turn the unit off and check whether anything is blocking the fan: built-up dirt, a leaf or a foreign object. Never put your hand in while the power is on.
When to call a technician
If the fan turns freely but does not run. The motor, its capacitor or the board needs testing.

4260 Heat sink overheating protection at start-up Try it yourself first

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

5101 Temperature sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

5102 Return air sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

5110 Outdoor inverter heat sink sensor error Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

5201 PS1 pressure sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

5301 Current sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

5701 Float connector loose Needs a technician

What it means
Condensate water isn't draining from the unit as it should, so the unit stopped itself to keep water from dripping into the room.
What you can do
Make sure the drain hose isn't kinked or blocked at its outer end, and that the indoor unit is level.
When to call a technician
If the hose looks fine from outside. An internal blockage or pump fault means opening the unit.

6201 Remote control problem Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

6600 Duplicate address on the M-Net network Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

6601 Polarity error; no voltage on the M-Net line Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

6602 Hardware error in the transmission processor from interference Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

6603 Transmission line busy Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

6606 Communication fault from a poor M-Net terminal connection Needs a technician

What it means
The indoor and outdoor units (or two boards inside the unit) exchange a signal over a wire, and that signal has been lost.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Make sure the outdoor unit's breaker is on. Note whether the code started after installation, relocation or a power cut.
When to call a technician
If the code comes back after restarting. Checking the cable and terminals is done with the power on, which is a technician's job.

6607 No acknowledgement signal Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

6608 No response Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

6831 MA controller signal reception error Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

6832 MA controller communication fault from a mismatched cable Needs a technician

What it means
The indoor and outdoor units (or two boards inside the unit) exchange a signal over a wire, and that signal has been lost.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Make sure the outdoor unit's breaker is on. Note whether the code started after installation, relocation or a power cut.
When to call a technician
If the code comes back after restarting. Checking the cable and terminals is done with the power on, which is a technician's job.

6833 MA controller communication fault from incorrect wiring Needs a technician

What it means
The indoor and outdoor units (or two boards inside the unit) exchange a signal over a wire, and that signal has been lost.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Make sure the outdoor unit's breaker is on. Note whether the code started after installation, relocation or a power cut.
When to call a technician
If the code comes back after restarting. Checking the cable and terminals is done with the power on, which is a technician's job.

6834 MA controller signal reception error Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

7100 Total capacity exceeds what the outdoor unit allows Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

7101 Capacity code setting error Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

7102 Incorrect number of connected units Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

7105 Address setting error Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

7106 Attribute setting error Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

7110 Signal transmission error from a loose connection Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

7111 Remote control sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

7113 Function setting error Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

7117 Model setting error Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

7130 Incompatible unit combination Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.