Daikin central air conditioning error codes

24 codes, each with what it means, what you can safely try yourself, and when to call a technician. Codes for VRV systems.

All the codes on this page come from a single unofficial source, and we have not yet found a second one confirming them. Treat them as a first hint and check them against your appliance's manual before any repair.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
AFHumidifier system not workingNeeds a technician
AHAir purifier dust collector not workingNeeds a technician
ECInlet water temperature abnormalNeeds a technician
EFThermal storage unit faultNeeds a technician
H1Humidifier unit damper not workingNeeds a technician
HCHot water sensor not workingNeeds a technician
HFIce problem in the thermal storage unitNeeds a technician
HJThermal storage tank water level abnormalNeeds a technician
JESub-tank sensor not workingNeeds a technician
JHOutdoor unit oil sensor not workingNeeds a technician
M1Central remote control not workingNeeds a technician
M8Optional controllers not communicatingNeeds a technician
MAWrong combination of optional controllersNeeds a technician
MCIncorrect addressesNeeds a technician
P2Automatic refrigerant charging stoppedNeeds a technician
P8Heat exchanger froze during refrigerant chargingNeeds a technician
P9Automatic refrigerant charging completeNot a fault
PAHeater wire damagedNeeds a technician
PCThe refrigerant cylinder ran empty during chargingNeeds a technician
PEAutomatic refrigerant charging almost finishedNot a fault
PHHumidifier unit temperature system faultNeeds a technician
U9Couldn't communicate between the unitsNeeds a technician
UECentral controller transmission interruptedNeeds a technician
UHTransmission between the units failedNeeds a technician

Every code explained

These systems run at high pressures on three-phase power. Nothing in them is opened without a qualified technician.

AF Humidifier system not working Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

AH Air purifier dust collector not working Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

EC Inlet water temperature abnormal Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

EF Thermal storage unit fault Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

H1 Humidifier unit damper not working Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

HC Hot water sensor not working Needs a technician

What it means
Condensate water isn't draining from the unit as it should, so the unit stopped itself to keep water from dripping into the room.
What you can do
Make sure the drain hose isn't kinked or blocked at its outer end, and that the indoor unit is level.
When to call a technician
If the hose looks fine from outside. An internal blockage or pump fault means opening the unit.

HF Ice problem in the thermal storage unit Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

HJ Thermal storage tank water level abnormal Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

JE Sub-tank sensor not working Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

JH Outdoor unit oil sensor not working Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

M1 Central remote control not working Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

M8 Optional controllers not communicating Needs a technician

What it means
The indoor and outdoor units (or two boards inside the unit) exchange a signal over a wire, and that signal has been lost.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Make sure the outdoor unit's breaker is on. Note whether the code started after installation, relocation or a power cut.
When to call a technician
If the code comes back after restarting. Checking the cable and terminals is done with the power on, which is a technician's job.

MA Wrong combination of optional controllers Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

MC Incorrect addresses Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.
Note
Also appears as UC

P2 Automatic refrigerant charging stopped Needs a technician

What it means
There is less refrigerant in the system than needed, usually because of a leak.
What you can do
Clean the filter and confirm that cooling really is weak. There is nothing else to do on your side.
When to call a technician
In almost every case. Ask the technician to find and repair the leak before recharging; recharging alone is only a temporary fix.

P8 Heat exchanger froze during refrigerant charging Needs a technician

What it means
The indoor coil got colder than it should and started to freeze, so the unit stopped the compressor to protect it.
What you can do
Clean the air filter, raise the fan speed, and don't set the temperature to the lowest setting for long periods. Leave the unit on fan mode until the ice melts.
When to call a technician
If the code keeps appearing with a clean filter, the refrigerant may be low or the fan weak.

P9 Automatic refrigerant charging complete Not a fault

What it means
An operating status, not a fault. The unit is telling you what it is doing right now.
What you can do
Nothing. Wait until the code disappears by itself.
When to call a technician
If the code stays for hours or keeps appearing without a clear reason.

PA Heater wire damaged Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

PC The refrigerant cylinder ran empty during charging Needs a technician

What it means
There is less refrigerant in the system than needed, usually because of a leak.
What you can do
Clean the filter and confirm that cooling really is weak. There is nothing else to do on your side.
When to call a technician
In almost every case. Ask the technician to find and repair the leak before recharging; recharging alone is only a temporary fix.

PE Automatic refrigerant charging almost finished Not a fault

What it means
An operating status, not a fault. The unit is telling you what it is doing right now.
What you can do
Nothing. Wait until the code disappears by itself.
When to call a technician
If the code stays for hours or keeps appearing without a clear reason.

PH Humidifier unit temperature system fault Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

U9 Couldn't communicate between the units Needs a technician

What it means
The indoor and outdoor units (or two boards inside the unit) exchange a signal over a wire, and that signal has been lost.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Make sure the outdoor unit's breaker is on. Note whether the code started after installation, relocation or a power cut.
When to call a technician
If the code comes back after restarting. Checking the cable and terminals is done with the power on, which is a technician's job.

UE Central controller transmission interrupted Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

UH Transmission between the units failed Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.