A3tali

Home ‹ Air conditioners ‹ Sharp

Sharp air conditioner error codes

30 codes, each with what it means, what you can safely try yourself, and when to call a technician.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
1-0Room temperature sensor reading short circuitNeeds a technician
1-1Indoor coil temperature sensor reading short circuitNeeds a technician
1-2Outdoor coil temperature sensor reading short circuitNeeds a technician
1-3Compressor discharge pipe temperature sensor reading short circuitNeeds a technician
1-4Outdoor ambient temperature sensor reading short circuitNeeds a technician
2-0Indoor coil overheating stopped the compressor for protectionNeeds a technician
2-1Compressor discharge temperature above the protection limitNeeds a technician
2-2Outdoor coil overheating above the protection limitNeeds a technician
2-3Discharge pipe overheating in heating mode above the limitNeeds a technician
3-0Dehumidifying mode stopped to protect the indoor coilNot a fault
5-0Room temperature sensor reading open circuitNeeds a technician
5-1Indoor coil temperature sensor reading open circuitNeeds a technician
5-2Outdoor coil temperature sensor reading open circuitNeeds a technician
5-3Compressor discharge pipe temperature sensor reading open circuitNeeds a technician
5-4Outdoor ambient temperature sensor reading open circuitNeeds a technician
6-0Overcurrent in the compressor circuitNeeds a technician
6-1Fault in the IPM power module driving the compressorNeeds a technician
7-0Current drawn from the mains above the limitNeeds a technician
7-1Current drawn lower than expectedNeeds a technician
9-0Fault in the electronic expansion valve and its drive circuitNeeds a technician
9-4Refrigerant leak detected, low circuit chargeNeeds a technician
10-0Board memory error (EEPROM)Needs a technician
11-0Outdoor fan not turningNeeds a technician
11-1Outdoor fan not reaching the required speedNeeds a technician
12-0Overheat protection fuse open in the outdoor unitNeeds a technician
13-0Compressor not runningNeeds a technician
13-1Compressor overloadNeeds a technician
14-0Power control circuit voltage out of rangeNeeds a technician
17-0Lost communication between the indoor and outdoor unitsNeeds a technician
18-0Serial communication fault between boardsNeeds a technician

Every code explained

Everything under “What you can do” is done without opening any cover. Opening the air conditioner or measuring its wiring with the power on is a technician's job.

1-0 Room temperature sensor reading short circuit Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
Reported causes
Damaged temperature sensor or shorted wire
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

1-1 Indoor coil temperature sensor reading short circuit Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
Reported causes
Damaged temperature sensor or shorted wire
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

1-2 Outdoor coil temperature sensor reading short circuit Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
Reported causes
Damaged temperature sensor or shorted wire
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

1-3 Compressor discharge pipe temperature sensor reading short circuit Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
Reported causes
Damaged temperature sensor or shorted wire
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

1-4 Outdoor ambient temperature sensor reading short circuit Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
Reported causes
Damaged temperature sensor or shorted wire
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

2-0 Indoor coil overheating stopped the compressor for protection Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
Reported causes
Dirty filter or weak airflow
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

2-1 Compressor discharge temperature above the protection limit Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
Reported causes
Low refrigerant or a blockage in the circuit
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

2-2 Outdoor coil overheating above the protection limit Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
Reported causes
Dirty outdoor fins or a weak fan
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

2-3 Discharge pipe overheating in heating mode above the limit Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
Reported causes
Low refrigerant or a blockage in the circuit
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

3-0 Dehumidifying mode stopped to protect the indoor coil Not a fault

What it means
An operating status, not a fault. The unit is telling you what it is doing right now.
Reported causes
Indoor coil got colder than it should
What you can do
Nothing. Wait until the code disappears by itself.
When to call a technician
If the code stays for hours or keeps appearing without a clear reason.

5-0 Room temperature sensor reading open circuit Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
Reported causes
Temperature sensor disconnected or its wire cut
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

5-1 Indoor coil temperature sensor reading open circuit Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
Reported causes
Temperature sensor disconnected or its wire cut
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

5-2 Outdoor coil temperature sensor reading open circuit Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
Reported causes
Temperature sensor disconnected or its wire cut
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

5-3 Compressor discharge pipe temperature sensor reading open circuit Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
Reported causes
Temperature sensor disconnected or its wire cut
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

5-4 Outdoor ambient temperature sensor reading open circuit Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
Reported causes
Temperature sensor disconnected or its wire cut
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

6-0 Overcurrent in the compressor circuit Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
Reported causes
Compressor overload or a drive fault
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

6-1 Fault in the IPM power module driving the compressor Needs a technician

What it means
A fault in the electronic control board or one of its parts.
Reported causes
The power module on the board isn't working
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Sometimes the fault is temporary after a power fluctuation.
When to call a technician
If the code comes back. The board is tested and repaired or replaced; ask for a diagnosis before agreeing to replace it, as it is one of the most expensive parts.

7-0 Current drawn from the mains above the limit Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
Reported causes
Overload or a board fault
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

7-1 Current drawn lower than expected Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
Reported causes
Compressor not running or a current measurement fault
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

9-0 Fault in the electronic expansion valve and its drive circuit Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
Reported causes
The valve isn't controlling the refrigerant flow
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

9-4 Refrigerant leak detected, low circuit charge Needs a technician

What it means
There is less refrigerant in the system than needed, usually because of a leak.
Reported causes
Low refrigerant gas due to a leak
What you can do
Clean the filter and confirm that cooling really is weak. There is nothing else to do on your side.
When to call a technician
In almost every case. Ask the technician to find and repair the leak before recharging; recharging alone is only a temporary fix.

10-0 Board memory error (EEPROM) Needs a technician

What it means
A fault in the electronic control board or one of its parts.
Reported causes
Setting data can't be read
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Sometimes the fault is temporary after a power fluctuation.
When to call a technician
If the code comes back. The board is tested and repaired or replaced; ask for a diagnosis before agreeing to replace it, as it is one of the most expensive parts.

11-0 Outdoor fan not turning Needs a technician

What it means
The fan is not turning, or it turns but the unit does not receive its rotation signal.
Reported causes
Fan motor or its capacitor faulty
What you can do
Turn the unit off and check whether anything is blocking the fan: built-up dirt, a leaf or a foreign object. Never put your hand in while the power is on.
When to call a technician
If the fan turns freely but does not run. The motor, its capacitor or the board needs testing.

11-1 Outdoor fan not reaching the required speed Needs a technician

What it means
The fan is not turning, or it turns but the unit does not receive its rotation signal.
Reported causes
Fault in the fan drive circuit
What you can do
Turn the unit off and check whether anything is blocking the fan: built-up dirt, a leaf or a foreign object. Never put your hand in while the power is on.
When to call a technician
If the fan turns freely but does not run. The motor, its capacitor or the board needs testing.

12-0 Overheat protection fuse open in the outdoor unit Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
Reported causes
The unit overheated and the thermal fuse tripped
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

13-0 Compressor not running Needs a technician

What it means
A problem running the compressor, the heart of the air conditioner.
Reported causes
The compressor start circuit isn't working
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back. Do not keep retrying, so the compressor is not damaged.

13-1 Compressor overload Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
Reported causes
Compressor current above the limit
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

14-0 Power control circuit voltage out of range Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
Reported causes
The voltage control circuit isn't stable
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

17-0 Lost communication between the indoor and outdoor units Needs a technician

What it means
The indoor and outdoor units (or two boards inside the unit) exchange a signal over a wire, and that signal has been lost.
Reported causes
Signal wire disconnected or a damaged board
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Make sure the outdoor unit's breaker is on. Note whether the code started after installation, relocation or a power cut.
When to call a technician
If the code comes back after restarting. Checking the cable and terminals is done with the power on, which is a technician's job.

18-0 Serial communication fault between boards Needs a technician

What it means
The indoor and outdoor units (or two boards inside the unit) exchange a signal over a wire, and that signal has been lost.
Reported causes
Signal harness disconnected or damaged
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Make sure the outdoor unit's breaker is on. Note whether the code started after installation, relocation or a power cut.
When to call a technician
If the code comes back after restarting. Checking the cable and terminals is done with the power on, which is a technician's job.

Sources