CF | Filter cleaning reminder | Try it yourself first |
dF | Automatic defrost mode | Not a fault |
E101 | Communication error between the indoor and outdoor units | Try it yourself first |
E102 | Communication error between the indoor and outdoor units | Try it yourself first |
E121 | Room temperature sensor error | Needs a technician |
E122 | Indoor evaporator pipe sensor error | Needs a technician |
E154 | Indoor fan error | Needs a technician |
E162 | Indoor unit memory error (EEPROM) | Needs a technician |
E163 | Option setting error | Needs a technician |
E202 | Communication error between the indoor and outdoor units | Try it yourself first |
E203 | Communication error between the main processor and the inverter processor | Needs a technician |
E221 | Outdoor ambient temperature sensor error | Needs a technician |
E231 | Condenser temperature sensor error | Needs a technician |
E251 | Discharge temperature sensor error | Needs a technician |
E416 | High discharge temperature, compressor stopped | Needs a technician |
E440 | Heating blocked because the outdoor temperature is above 30 | Not a fault |
E441 | Cooling blocked because the outdoor temperature is below minus 5 | Not a fault |
E458 | Outdoor fan error | Needs a technician |
E461 | Compressor failed to start | Needs a technician |
E462 | Stopped by the input current limit | Needs a technician |
E464 | Overcurrent in the IPM power module | Needs a technician |
E465 | Compressor overload | Needs a technician |
E466 | DC bus voltage above or below the limit | Needs a technician |
E468 | Current sensor error | Needs a technician |
E469 | DC bus voltage sensor error | Needs a technician |
E470 | Outdoor unit memory error (EEPROM) | Needs a technician |
E471 | Outdoor unit memory error (EEPROM) | Needs a technician |
E474 | Heat sink sensor error | Needs a technician |
E483 | Overvoltage protection | Needs a technician |
E484 | PFC circuit overload | Needs a technician |
E485 | Input current sensor error | Needs a technician |
E488 | Input voltage sensor error | Needs a technician |
E500 | Power module heat sink overheating | Try it yourself first |
E554 | Gas leak detected | Needs a technician |
Ch | Compressor start delayed to run the crankcase heater | Not a fault |
P0 | Stopped due to high discharge sensor temperature | Needs a technician |
P1 | Stopped due to high condenser temperature | Try it yourself first |
P3 | Stopped by the low-temperature switch | Needs a technician |
P4 | Stopped at start-up due to reversed phase | Needs a technician |
P5 | Stopped due to heat exchanger freezing | Try it yourself first |
P6 | Momentary power interruption | Try it yourself first |
P7 | Compressor stopped by the high-pressure sensor protection | Needs a technician |
P8 | Compressor stopped by the low-pressure sensor protection | Needs a technician |
P9 | Defrost problem | Needs a technician |
PA | Compressor stopped by the compression ratio protection | Needs a technician |
t1 | Outdoor temperature sensor error | Needs a technician |
t2 | Condenser temperature sensor error | Needs a technician |
t3 | Discharge temperature sensor error | Needs a technician |
t4 | Liquid pipe sensor error at the condenser outlet | Needs a technician |
t6 | Suction temperature sensor error | Needs a technician |
t7 | High-pressure sensor error | Needs a technician |
t8 | Low-pressure sensor error | Needs a technician |
E1 | Stopped due to a communication error after tracking | Needs a technician |
E3 | Indoor unit float switch error | Try it yourself first |
E5 | Indoor unit option switch setting error | Needs a technician |
Ax | Evaporator inlet sensor disconnected | Needs a technician |
bx | Evaporator outlet sensor disconnected | Needs a technician |
Cx | Electronic expansion valve opening error | Needs a technician |
dx | Electronic expansion valve closing error | Needs a technician |
fx | Both evaporator inlet and outlet sensors disconnected | Needs a technician |
G2 | Total refrigerant loss in the outdoor unit | Needs a technician |
G3 | Condenser middle sensor disconnected | Needs a technician |
G7 | Suction sensor disconnected | Needs a technician |
GC | Compressor discharge sensor disconnected | Needs a technician |
9x | Room sensor open or shorted | Needs a technician |
rx | Evaporator inlet sensor open or shorted | Needs a technician |
yx | Evaporator outlet sensor open or shorted | Needs a technician |
ux | Fan setting error | Needs a technician |
tU | Outdoor temperature below minus 5 in cooling | Not a fault |
to | Outdoor temperature above 30 in heating | Not a fault |
E108 | Error due to a duplicate communication address | Needs a technician |
E123 | Evaporator outlet sensor error | Needs a technician |
E128 | Evaporator inlet sensor disconnected | Needs a technician |
E129 | Evaporator outlet sensor disconnected | Needs a technician |
E130 | Both evaporator inlet and outlet sensors disconnected | Needs a technician |
E131 | Auxiliary electric heater sensor 1 error | Needs a technician |
E132 | Auxiliary electric heater sensor 2 error | Needs a technician |
E133 | Auxiliary electric heater sensor 3 error | Needs a technician |
E134 | Shutter sensor error | Needs a technician |
E135 | Fan sensor error | Needs a technician |
E140 | MCU temperature sensor open or shorted | Needs a technician |
E151 | Indoor expansion valve failed to open | Needs a technician |
E152 | Indoor expansion valve failed to close | Needs a technician |
E153 | Indoor unit float switch activated | Try it yourself first |
E165 | Electric heater air temperature protection | Needs a technician |
E166 | No fan running with the electric heater | Needs a technician |
E167 | Central controller setting error | Needs a technician |
E198 | Indoor unit thermal fuse error | Needs a technician |
E226 | Outdoor temperature sensor disconnected | Needs a technician |
E236 | Main condenser outlet sensor open or shorted | Needs a technician |
E237 | Condenser temperature sensor error | Needs a technician |
E241 | Condenser middle sensor disconnected | Needs a technician |
E246 | Condenser outlet sensor 1 disconnected | Needs a technician |
E261 | Digital discharge sensor disconnected | Needs a technician |
E269 | Suction sensor disconnected | Needs a technician |
E291 | High-pressure sensor open or shorted | Needs a technician |
E296 | Low-pressure sensor open or shorted | Needs a technician |
E301 | High-pressure sensor disconnected | Needs a technician |
E306 | Low-pressure sensor disconnected | Needs a technician |
E308 | Suction temperature sensor open or shorted | Needs a technician |
E312 | Main cooling valve opening error | Needs a technician |
E313 | Four-way valve operating error | Needs a technician |
E320 | OLP overload protection sensor error | Needs a technician |
E403 | Compressor stopped due to outdoor unit freezing | Needs a technician |
E404 | Outdoor unit overload protection 1 | Needs a technician |
E407 | Compressor stopped by high-pressure sensor protection 1 | Needs a technician |
E410 | Compressor stopped by low-pressure sensor protection 1 | Needs a technician |
E419 | Outdoor expansion valve 1 opening error | Needs a technician |
E425 | Reversed phase detected on outdoor unit 1 | Needs a technician |
E438 | EVI valve opening error | Needs a technician |
E439 | Refrigerant leak while stopped | Needs a technician |
E442 | Refrigerant charging error in heating mode | Needs a technician |
E443 | Refrigerant leak while running | Needs a technician |
E452 | Momentary power interruption | Try it yourself first |
E453 | Fan motor overheating | Needs a technician |
E454 | Fan motor speed error | Needs a technician |
E455 | Fan motor power module overheating | Needs a technician |
E456 | Fan motor overvoltage | Needs a technician |
E457 | Fan motor reverse rotation | Needs a technician |
E460 | Wiring error between the communication cable and the power cable | Needs a technician |
E463 | System stopped by OLP overload temperature control | Needs a technician |
E475 | Inverter fan 2 error | Needs a technician |
E508 | Smart installation mode error | Needs a technician |
E551 | Defrost mode | Not a fault |
E552 | Low discharge pressure | Needs a technician |
E556 | Indoor and outdoor unit capacity mismatch | Needs a technician |
E601 | Communication error between the wired remote controller and the indoor unit | Needs a technician |
E602 | Communication error between the main and sub wired remote controllers | Needs a technician |
E603 | Communication error between the weekly timer and the wired remote controller | Needs a technician |
E701 | Float switch activated | Try it yourself first |
E702 | Indoor expansion valve closing error | Needs a technician |
E703 | Indoor expansion valve opening error | Needs a technician |