Carrier air conditioner error codes

25 codes, each with what it means, what you can safely try yourself, and when to call a technician.

All the codes on this page come from a single unofficial source, and we have not yet found a second one confirming them. Treat them as a first hint and check them against your appliance's manual before any repair.

A code's meaning can differ between models of the same brand. Check what you find here against your appliance's manual before any repair.

Quick table

CodeMeaningWho handles it
E0Indoor unit memory error (EEPROM)Needs a technician
E1Indoor–outdoor unit communication faultTry it yourself first
E2Zero-crossing signal errorNeeds a technician
E3Indoor fan speed faultNeeds a technician
E4Room temperature sensor open or shortedNeeds a technician
E5Evaporator coil sensor open or shortedNeeds a technician
E6Room sensor or evaporator sensor faultNeeds a technician
E7Outdoor fan speed faultNeeds a technician
E8Overload protectionNeeds a technician
E9Cold-draft preventionNot a fault
ECRefrigerant leak detectedNeeds a technician
F1Outdoor ambient temperature sensor faultNeeds a technician
F2Condenser coil sensor open or shortedNeeds a technician
F3Compressor discharge temperature sensor faultNeeds a technician
F4Outdoor unit memory error (EEPROM)Needs a technician
F5Outdoor fan speed faultNeeds a technician
H1Defrost or oil-return cycleNot a fault
H3Compressor overheating protectionNeeds a technician
H5IPM power module protectionNeeds a technician
LCCompressor failed to startNeeds a technician
P0Power module overcurrent protectionNeeds a technician
P1High or low voltage protectionNeeds a technician
P2Compressor high-temperature protectionNeeds a technician
P4Inverter compressor drive errorNeeds a technician
P5Compressor current protectionNeeds a technician

Every code explained

Everything under “What you can do” is done without opening any cover. Opening the air conditioner or measuring its wiring with the power on is a technician's job.

E0 Indoor unit memory error (EEPROM) Needs a technician

What it means
A fault in the electronic control board or one of its parts.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Sometimes the fault is temporary after a power fluctuation.
When to call a technician
If the code comes back. The board is tested and repaired or replaced; ask for a diagnosis before agreeing to replace it, as it is one of the most expensive parts.

E1 Indoor–outdoor unit communication fault Try it yourself first

What it means
The indoor and outdoor units (or two boards inside the unit) exchange a signal over a wire, and that signal has been lost.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Make sure the outdoor unit's breaker is on. Note whether the code started after installation, relocation or a power cut.
When to call a technician
If the code comes back after restarting. Checking the cable and terminals is done with the power on, which is a technician's job.

E2 Zero-crossing signal error Needs a technician

What it means
The air conditioner detected a fault and stopped because of it.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back after restarting.

E3 Indoor fan speed fault Needs a technician

What it means
The fan is not turning, or it turns but the unit does not receive its rotation signal.
What you can do
Turn the unit off and check whether anything is blocking the fan: built-up dirt, a leaf or a foreign object. Never put your hand in while the power is on.
When to call a technician
If the fan turns freely but does not run. The motor, its capacitor or the board needs testing.

E4 Room temperature sensor open or shorted Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

E5 Evaporator coil sensor open or shorted Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

E6 Room sensor or evaporator sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

E7 Outdoor fan speed fault Needs a technician

What it means
The fan is not turning, or it turns but the unit does not receive its rotation signal.
What you can do
Turn the unit off and check whether anything is blocking the fan: built-up dirt, a leaf or a foreign object. Never put your hand in while the power is on.
When to call a technician
If the fan turns freely but does not run. The motor, its capacitor or the board needs testing.

E8 Overload protection Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

E9 Cold-draft prevention Not a fault

What it means
An operating status, not a fault. The unit is telling you what it is doing right now.
What you can do
Nothing. Wait until the code disappears by itself.
When to call a technician
If the code stays for hours or keeps appearing without a clear reason.

EC Refrigerant leak detected Needs a technician

What it means
There is less refrigerant in the system than needed, usually because of a leak.
What you can do
Clean the filter and confirm that cooling really is weak. There is nothing else to do on your side.
When to call a technician
In almost every case. Ask the technician to find and repair the leak before recharging; recharging alone is only a temporary fix.

F1 Outdoor ambient temperature sensor fault Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

F2 Condenser coil sensor open or shorted Needs a technician

What it means
A small sensor that measures temperature or pressure somewhere in the unit is giving an illogical reading, or its wire is disconnected.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. That is all you can do on your side.
When to call a technician
If the code comes back. The technician measures the sensor with a meter and replaces it if faulty; it is one of the simplest repairs.

F3 Compressor discharge temperature sensor fault Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

F4 Outdoor unit memory error (EEPROM) Needs a technician

What it means
A fault in the electronic control board or one of its parts.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Sometimes the fault is temporary after a power fluctuation.
When to call a technician
If the code comes back. The board is tested and repaired or replaced; ask for a diagnosis before agreeing to replace it, as it is one of the most expensive parts.

F5 Outdoor fan speed fault Needs a technician

What it means
The fan is not turning, or it turns but the unit does not receive its rotation signal.
What you can do
Turn the unit off and check whether anything is blocking the fan: built-up dirt, a leaf or a foreign object. Never put your hand in while the power is on.
When to call a technician
If the fan turns freely but does not run. The motor, its capacitor or the board needs testing.

H1 Defrost or oil-return cycle Not a fault

What it means
An operating status, not a fault. The unit is telling you what it is doing right now.
What you can do
Nothing. Wait until the code disappears by itself.
When to call a technician
If the code stays for hours or keeps appearing without a clear reason.

H3 Compressor overheating protection Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

H5 IPM power module protection Needs a technician

What it means
A fault in the electronic control board or one of its parts.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on. Sometimes the fault is temporary after a power fluctuation.
When to call a technician
If the code comes back. The board is tested and repaired or replaced; ask for a diagnosis before agreeing to replace it, as it is one of the most expensive parts.

LC Compressor failed to start Needs a technician

What it means
A problem running the compressor, the heart of the air conditioner.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back. Do not keep retrying, so the compressor is not damaged.

P0 Power module overcurrent protection Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

P1 High or low voltage protection Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

P2 Compressor high-temperature protection Needs a technician

What it means
The unit cannot reject heat outdoors fast enough, so pressure or temperature rose and it shut itself down.
What you can do
Clean the indoor unit's filter, and make sure the outdoor unit is not surrounded by obstructions and its fins are not clogged with dust. Shade it if it sits in direct sun.
When to call a technician
If the code returns even with good ventilation. The refrigerant charge may be too high or the outdoor fan weak.

P4 Inverter compressor drive error Needs a technician

What it means
A problem running the compressor, the heart of the air conditioner.
What you can do
Switch the air conditioner off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code comes back. Do not keep retrying, so the compressor is not damaged.

P5 Compressor current protection Needs a technician

What it means
The power reaching the unit is above or below the limit, or the unit is drawing more current than allowed.
What you can do
Notice whether the lights in your home dim or flicker. Do not run the unit on an extension lead. Switch it off at the breaker for five minutes, then turn it back on.
When to call a technician
If the code keeps appearing. The voltage is measured at the unit; the problem may be in the home's wiring or in the unit's board.

Sources